Eaton Fuller Hybrid Transmission Sesar Code 116 – Tinggi tegangan Relays Sesar – (sistem MY09)

Lepat kode pikeun Eaton Hybrid Girang Systems model (MY09) EH-8E406A-U / P, EH-8E406A-up, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P jeung EH-6E706B-UPG. Baca di handap pikeun diajar kumaha carana test, écés sarta ngalereskeun kasalahan kode sesar pikeun Freightliner Anjeun, Mack, Peterbilt, Kenworth, Volvo, internasional, jeung beurat-tugas treuk jeung alat. The Relays High-tegangan nu lokasina di jero Power nu
éléktronika Carrier (PEC) dina Unit Relay Box. There is one Pre-Charge Relay on the positive side, an additional relay on the positive, and on the negative for a total of three relays. relays ieu normalna kabuka lamun sistem pareum. The relays nu dikawasa ngaliwatan Inverter nu.

lepat Code 116 – Tinggi tegangan Relays Sesar deteksi

The preconditions handap kudu patepung méméh sistem ngadeteksi sesar teh:

  • tegangan Inverter ignition anu leuwih gede ti 7 volt jeung kirang ti 16 volt.

Catetan: Nalika ngungkulan hiji kode aktif tingal Produk Mode diagnostik (PDM)

Kaayaan keur Atur Sesar Code Active

  • IMF 3 diatur lamun pondok pikeun 12 volt nu dideteksi dina samping kadali a relay-tegangan tinggi.
  • IMF 4 diatur lamun pondok ka taneuh nu dideteksi dina samping kadali a relay-tegangan tinggi.
  • IMF 5 sarta FMI 10 nu diatur nalika hiji sirkuit dideteksi dina samping kadali a relay-tegangan tinggi.
  • IMF 7 sarta FMI 14 nu diatur nalika relay négatip utama dina jeung inverter panurunan tegangan kapasitor nyaeta kirang ti 10-volt / 5 detik lamun tegangan kapasitor awal éta leuwih gede ti 200 volt.

Fallback Nalika Sesar Code 116 diatur kaayaan di handap lumangsung:

  • Amber "Cék Hybrid" illuminates lampu.
  • Sesar disimpen dina Control Hybrid Module (HCM) ingetan.
  • Sistem hibrida bakal offline.
  • Transmission defaults start gear to 1st in diesel-only mode.

Kaayaan keur Atur Sesar Code aktif

Ngan faults aktif bisa diberesihan tina TECU atanapi HCM sajarah maké ServiceRanger. The TECU otomatis Leungitkeun dina faults tina sajarah sanggeus 200 jam. The HCM otomatis Leungitkeun a lepat tina sajarah sanggeus sesar eta geus teu aktif 200 jam.

Kode lepat ieu bisa disababkeun ku salah sahiji handap:

  • IMF 3, 4, 5, 7, 10, 14
    • Tegangan Eupan Balik kawat ti DC / DC Parabot Parobah mun HCM
  • IMF 4
    • relay Box
    • inersia Pindah
    • Inverter
    • Wahana wiring Abah antara Inverter jeung PEC
    • Main High-tegangan Service ngahiji ieu ditiup atawa leungit
    • DC High-tegangan Cable Interlock
    • PEC Beureum Button Service Pindah

lepat Code 116 – Tinggi tegangan Relays Sesar Test

Identification komponén:

Duetsch 40-way mating connector view Inverter low-voltage connector

Duetsch 40-cara tempoan konektor jalangan
(Inverter konektor-tegangan low)

Mating connector view Deutsch 19-way

Jalangan view konektor
(Deutsch konektor 19-jalan)

CATETAN: Tingal Eaton Hybrid Cibalong sarta Panyambung lokasi pikeun Panyambung Locations di MY09 Systems.

Inverter to PEC MY09 Systems