Eaton Fuller Hybrid Transmission Sesar Code 129 – Unit APG 1 komunikasi

Lepat kode pikeun Eaton Hybrid Girang Systems model (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-up, EH-8E306A-CD, EH-8E306A-T and EH-6E606B-CD. Baca di handap pikeun diajar kumaha carana test, écés sarta ngalereskeun kasalahan kode sesar pikeun Freightliner Anjeun, Mack, Peterbilt, Kenworth, Volvo, internasional, jeung beurat-tugas treuk jeung alat. The bantu Power generator (APG) mangrupakeun Inverter 5kW / 5kVA DC / AC nu disambungkeun ka tegangan tinggi DC beus tina sistem kandaraan listrik Hybrid Eaton, jeung dibangkitkeun 60 -Fase tunggal kakuatan AC 120-volt Hz pikeun aplikasi utiliti. Controller Area Network (bisa) mangrupakeun-speed tinggi twisted pasangan 500K data proprietary link anu ngahubungkeun HCM ka Electric clutch Actuator (béca), Module Control batré, Inverter na APG. link ngandung hiji 120 ohm résistor dina unggal tungtung. The link is used to transmit information specific to clutch position and power electronics operations.

lepat Code 129 – Unit APG 1 Communication Detection

The preconditions handap kudu patepung méméh sistem ngadeteksi sesar teh:

  • HCM nyaeta Powered jeung tegangan ignition anu leuwih gede ti 7 volt jeung kirang ti 16 volt.

Catetan: Nalika ngungkulan hiji kode aktif tingal Produk Mode diagnostik (PDM)

Kaayaan keur Atur Sesar Code Active

  • IMF 9: Communication with the HCM has not occurred for more than 2 detik.

Fallback Nalika Sesar Code 129 diatur kaayaan di handap lumangsung:

  • Amber "Cék Hybrid" illuminates lampu.
  • If the fault sets during operation the APG shuts off.

Kaayaan keur Atur Sesar Code aktif

Ngan faults aktif bisa diberesihan tina Unit Transmission Control Electronic (TECU) atanapi sajarah HCM maké ServiceRanger. The TECU otomatis Leungitkeun dina faults tina sajarah sanggeus 200 jam jeung HCM otomatis Leungitkeun dina faults tina sajarah sanggeus sesar nu geus inaktif 200 jam.

Kode lepat ieu bisa disababkeun ku salah sahiji handap:

  • IMF 9
    • APG
    • HCM
    • Tiasa Data Link

lepat Code 129 – Unit APG 1 Communication Test

Identification komponén:

APG 8-way low-voltage connector view

APG 8-way low-voltage
connector view

9-way diagnostic connector

Deutsch 4 arah konektor OEM

CATETAN: Tingal Eaton Hybrid Cibalong sarta Panyambung lokasi pikeun Panyambung Locations di MY08 Systems

sagala bagian transmisi anjeun peryogi urang gaduh eta! pengiriman barang dinten anu sami sadia, di sakuliah dunya.

Kudu ngarojong FREE ti salah sahiji ahli kami?

nelepon AYEUNA