Eaton Fuller Hybrid Transmission Sesar Code 118 – Bantu High-tegangan Circuit Control Relay (MY08 Systems)

Lepat kode pikeun Eaton Hybrid Girang Systems model (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-up, EH-8E306A-CD, EH-8E306A-T and EH-6E606B-CD. Baca di handap pikeun diajar kumaha carana test, écés sarta ngalereskeun kasalahan kode sesar pikeun Freightliner Anjeun, Mack, Peterbilt, Kenworth, Volvo, internasional, jeung beurat-tugas treuk jeung alat. The bantu High-tegangan Relays lokasina di Electronics Carrier Daya (PEC) nu dikawasa ku Control Module Hybrid (HCM). Di konci on, kakuatan-tegangan tinggi disadiakeun ti kotak relay ka bantu High-tegangan Relays. Lamun pilihan ePTO dipilih dina Push Button Shift Control, nu HCM energizes nu sirkuit kontrol pikeun relays négatip utama positif sarta utama. kakuatan nu lajeng ngalir ngaliwatan bantu High-tegangan Relays kana Parabot Parobah DC / DC.

lepat Code 118 – Bantu High-tegangan Relay Control Circuit deteksi

The preconditions handap kudu patepung méméh sistem ngadeteksi sesar teh:

  • Hybrid Control Module (HCM) tegangan ignition anu leuwih gede ti 7 volt jeung kirang ti 16 volt.

Catetan: Nalika ngungkulan hiji kode aktif tingal Produk Mode diagnostik (PDM)

Kaayaan keur Atur Sesar Code Active

  • IMF 3 is set when the HCM detects a short to battery in the coil circuit of the Auxiliary High-Voltage Relay.
  • IMF 4 is set when the HCM detects a short to ground in the coil circuit of the Auxiliary High-Voltage Relay.
  • IMF 5 diatur nalika HCM nu ngadeteksi hiji kabuka dina sirkuit coil tina bantu High-tegangan Relay.

Fallback Nalika Sesar Code 118 diatur kaayaan di handap lumangsung:

  • Amber "Cék Hybrid" illuminates lampu.
  • Sesar disimpen dina Control Hybrid Module (HCM) ingetan.
  • The DC / DC Parabot Parobah teu beroperasi sabab HCM de-energizes nu-tegangan tinggi circuit relay bantu.

Kaayaan keur Atur Sesar Code aktif

Ngan faults aktif bisa diberesihan tina Unit Transmission Control Electronic (TECU) atanapi sajarah HCM maké ServiceRanger. The TECU otomatis Leungitkeun dina faults tina sajarah sanggeus 200 jam jeung HCM otomatis Leungitkeun dina faults tina sajarah sanggeus sesar nu geus inaktif 200 jam.

Kode lepat ieu bisa disababkeun ku salah sahiji handap:

  • IMF 3, 4, 5
    • PEC
    • System Hybrid Abah
    • DC Cable High-tegangan Citakan: Loop
    • DC / DC Parabot Parobah

lepat Code 118 – Bantu High-tegangan Relay Control Circuit Test

sagala bagian transmisi anjeun peryogi urang gaduh eta! pengiriman barang dinten anu sami sadia, di sakuliah dunya.

Kudu ngarojong FREE ti salah sahiji ahli kami?

nelepon AYEUNA
email AS