Eaton Fuller Code Hybrid Fault 6 – No HCM Operation

Faji Kodi për Eaton Hybrid Sistemet Drive modele (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P dhe EH-6E706B-UPG. Kontrolli Moduli Hybrid (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

faj Kodin 6 – No HCM Operation Detection

Parakushtet e mëposhtme duhet të plotësohen para se sistemi zbulon defektin:

  • HCM ndezjen tension është më i madh se 7 volt dhe më pak se 16 volt.

Kushtet për Set Kodi Fault Active

Kushtet për të Set Faj:

  • FMN 12 is set at key on if the HCM detects an internal failure.
  • FMN 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Kur Code Fault 6 është vendosur ndodhin kushtet e mëposhtme:
• Amber "Kontrollo Hibrid" hedh dritë të lehta.
• If the fault occurs at power up the vehicle may not crank.

Kushtet për Set Fault Code joaktiv

Vetëm gabime jo aktive mund të pastrohen nga Njësia e kontrollit elektronik të Transmisionit (TECU) ose historia HCM përdorur ServiceRanger. TECU automatikisht pastron gabimet nga historia pas 200 orë. HCM automatikisht pastron gabimet nga historia pas faj ka qenë inaktive për 200 orë.

Ky kod faji mund të shkaktohet nga ndonjë nga këto:

  • FMN 12, 14
    • HCM