Eaton Fuller Sesar Code 4 motor / Generator Rotation Speed sénsor
Lepat kode pikeun Eaton Hybrid Girang Systems model (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-up, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-up, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P jeung EH-6E706B-UPG. Siliwangi / generator Rotation Speed sensor anu dipasang kana balik ti Motor / generator sabudeureun aci Input. sensor (Desain dua-sapotong) mangrupakeun rotor dipasang kana Input aci sarta Ring sensing dipasang kana perumahan motor. The sensing Ring disadiakeun kalawan low-voltage mangsa operasi. rotor nu kabukti inducing hiji turun naek tegangan kana Ring sensing, nu lajeng dirobah kana sinyal digital pikeun Motor / generator rpm. output tegangan jeung frékuénsi nyaéta low di dianggurkeun sarta ngaronjatkeun kalayan rpm.
lepat Code 4 – Motor / generator Rotation Speed sensor beungeut
- tegangan Inverter ignition anu leuwih gede ti 7 volt jeung kirang ti 16 volt.
- IMF 2 teu diatur lamun aya hiji Active Transmission Input aci Speed sensor sesar.
Kaayaan keur Atur Sesar Code Active
Kaayaan keur Atur Faul Code Active:
- IMF 0 diatur nalika laju Motor / generator ngaleuwihan rentang allowable normal.
- IMF 2 diatur nalika laju Motor / generator mah béda ti Transmission Input aci Speed ku leuwih ti 100 Rpm salila sahenteuna 10 detik.
- IMF 3: Set when the resolver circuit is shorted to ground.
- IMF 21: Set when a resolver signal line short to 12-volt battery or ground is detected.
- IMF 22, 24, 25 nu diatur nalika kombinasi sinyal converter analog-to-digital anu mismatch a.
- IMF 27 diatur nalika Inverter nu ngadeteksi kasalahan dina mangsa dipariksa awal.
- IMF 23 diatur lamun aya sinyal kasalahan kaluaran analog-to-digital converter pikeun 100 IBU.
- IMF 26 diatur nalika laju sensor rotasi anu leuwih gede ti 6000 mnt-1 keur 10 IBU.
Fallback Nalika Sesar Code 4 diatur kaayaan di handap lumangsung:
• Amber "Cék Hybrid" illuminates lampu.
• Sesar disimpen dina Control Hybrid Module (HCM) ingetan.
• Electric Motor/Generator Assist and Regeneration are disabled; kumaha oge, nu relays-tegangan tinggi tetep Powered.
• HCM continues to control the hybrid vehicle in a diesel-only mode.
• ingkar Transmission ngamimitian gear mun 1st.
Kaayaan keur Atur Sesar Code aktif
Ngan faults aktif bisa diberesihan tina Unit Transmission Control Electronic (TECU) atanapi sajarah HCM maké ServiceRanger. The TECU otomatis Leungitkeun dina faults tina sajarah sanggeus 200 jam. The HCM otomatis Leungitkeun dina faults tina sajarah sanggeus sesar nu geus inaktif 200 jam
Kode lepat ieu bisa disababkeun ku salah sahiji handap:
MY08
- IMF 0
- sasmita ngalegaan lila bisa merlukeun pamakéan intermittent tina rem jasa ngalambatkeun wahana
- IMF 22, 24, 25, 27
- Inverter
- IMF 2, 23, 26
- Inverter
- Motor / generator
- Resolver Abah antara Motor / generator na Inverter
MY09
- IMF 3, 21
- Inverter
- Resolver Harness between the motor/generator
and Inverter
- IMF 2, 22, 23, 24, 25, 27
- Inverter
- Motor / generator
- Resolver Abah antara Motor / generator na Inverter
- Water in Inverter or Resolver wire connector
lepat Code 4 – Motor / generator Rotation Speed sensor Test
System komponén Identification MY08:
Delphi 56-Jalan jalangan Panyambung Témbongkeun
Resolver Abah Témbongkeun (Sisi hareup)
CATETAN: Tingal Eaton Hybrid Cibalong sarta Panyambung lokasi pikeun Panyambung Locations di MY08 Systems
System komponén Identification MY09:
Deutsch 40-Jalan jalangan Panyambung Témbongkeun
Eaton Terminal Side – Harness Connector Resolver Deutsch 6-pin connector
CATETAN: Tingal Eaton Hybrid Cibalong sarta Panyambung lokasi pikeun Panyambung Locations di MY09 Systems.
sagala bagian transmisi anjeun peryogi urang gaduh eta! pengiriman barang dinten anu sami sadia, di sakuliah dunya.
Kudu ngarojong FREE ti salah sahiji ahli kami?