[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybridgetriebe Fehlercode 114 – Inverter Stromversorgung
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Fehlercode für Eaton Hybrid Drive System Modelle (MY08) EH-U-8E306A, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P und EH-6E706B-UPG. Lesen Sie unten, um zu erfahren wie zu testen, löschen und Fehlercode Fehler für Ihre Freight beheben, Mack, Peterbilt, Kenworth, Volvo, International, schwere und schwere Lkw und Ausrüstung. The Inverter assembly uses a 12V or 24V supply provided from the Hybrid Control Module (HCM) to power the Internal Control Board. The HCM provides ignition power to the Internal Control Board after it completes the power-up self-check.
Falscher Code 114 – Inverter Stromversorgung Erkennung
Folgende Voraussetzungen müssen erfüllt sein, bevor das System den Fehler erkennt:
- Hybrid-Steuermodul (HCM) Zündspannung größer ist als 7 Volt und weniger als 16 Volt.
Hinweis: Wenn Sie eine inaktive Code zur Fehlerbehebung finden Sie in der Produktdiagnosemodus (PDM)
Bedingungen setzen Fehlercode Aktiv
- IWF 3 gesetzt, wenn die Wechselrichter-Zündspannung größer ist als 16 Volt 0.5 Sekunden.
- IWF 4 gesetzt, wenn die Inverter Zündspannung kleiner als 7 Volt 0.1 Sekunden.
Notlösung, wenn Fehlercode 114 die folgenden Bedingungen auftreten, eingestellt ist:
- Bernstein „prüfen Hybrid“ Licht leuchtet.
- Der Fehler wird in Hybrid-Steuermodul gespeichert (HCM) Erinnerung.
- Elektromotor / Generator-Assistent und der Regeneration sind deaktiviert; jedoch, Hochspannungsrelais bleibt angetriebenen.
- HCM weiterhin das Hybridfahrzeug in einem Modus nur mit Diesel zu steuern,.
- Getriebe Standardwerte starten Gang 1..
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Bedingungen einzustellen Fehlercode Inaktive
Nur inaktive Fehler können von der Transmission Electronic Control Unit gelöscht werden (TECU) oder HCM Geschichte mit Serviceranger. Die TECU löscht automatisch die Fehler aus der Geschichte nach dem 200 Stunden und die HCM löscht automatisch die Fehler aus der Geschichte nach dem Fehler waren inaktiv für 200 Std.
Dieser Fehlercode kann durch eine der folgenden Bedingungen verursacht werden:
- IWF 1
- Wandler
- IWF 3
- Wandler
- IWF 4
- HCM
- Wandler
- Stromversorgungskabel von HCM-Umrichter
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Falscher Code 114 – Inverter Stromversorgung-Test
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identifizierung der Komponenten MY08-Systeme:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Hybrid-System-Interface-Stecker” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Harness Vorderansicht
(HCM – Hybrid-System-Interface-Stecker)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14474|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Inverter 56-Wege-Gegenstecker Ansicht” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-56-Way-Mating-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Inverter 56-Wege-Gegenstecker Ansicht
(Wandler – Low-Voltage-Anschluss)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
HINWEIS: Siehe die Eaton Hybrid Komponenten und Stecker-Position für Connector Standorte in MY08-Systeme
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14650|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM zu Wechselrichter-Anschluss für Eaton Fuller Übertragungs” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-to-Inverter-MY08.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”20″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identifizierung der Komponenten MY09-Systeme:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Hybrid-System-Interface-Stecker” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Harness Vorderansicht
(HCM – Hybrid-System-Interface-Stecker)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14476|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40-Wege-Gegenstecker Ansicht” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Deutsch 40-Wege-Gegenstecker Ansicht
(Wandler – Low-Voltage-Anschluss)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
HINWEIS: Siehe die Eaton Hybrid Komponenten und Stecker-Position für Connector Standorte in MY09-Systeme.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14651|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM-Anschluss für die Inverter Fuller Übertragung MY09″ link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-to-Inverter-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”Warnungen & Verwarnungen” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Achtung: Gefahr bedeutet, Sie schwer verletzt werden oder getötet, wenn nicht die angegebene Prozedur folgen.
Warnung: Warnung zeigt eine unmittelbare Gefahr, die zu schweren Verletzungen führen kann, wenn Sie die angegebenen Verfahren nicht folgen.
Vorsicht: Vorsicht bedeutet, Fahrzeug oder Sachschäden können auftreten, wenn Sie die angegebene Verfahren nicht folgen.
Hinweis: Hinweis kennzeichnet zusätzliche Details, die bei der Diagnose oder Reparatur eines Bauteils / System helfen werden.
Folgen Sie das festgelegte Verfahren in der angegebenen Reihenfolge um Verletzungen zu vermeiden:
1. Wenn die Hochspannungs-Kegel sind rund um das Fahrzeug und die Sperre auf dem PEC installiert, die einzige Person, die das Fahrzeug starten erlaubt sein soll, ist die Person, die die Aussperrung Tag unterzeichnet.
2. Vor dem Arbeiten an einem Fahrzeug oder Verlassen der Kabine, während der Motor läuft, Sie sollten den Schalthebel in „N“ legen Sie die Feststellbremse eingestellt, und blockieren die Räder.
3. Aus Sicherheitsgründen, immer in Eingriff mit den Betriebsbremsen vor Gangpositionen von „N“ zu der Auswahl
4. Vor dem Start ein Fahrzeug immer auf dem Fahrersitz sitzt, Auswahl von „N“ auf der Schaltsteuerung, und die Feststellbremsen.
5. Bei Fahrzeugen mit EPTO, der Motor und / oder
Motor / Generator kann in EPTO Modus starten. Sie keine Wartungsarbeiten durchführen oder auf Fahrzeug arbeiten, in diesem Modus.
6. 12-Volt Batterie-Plus (+) und negative (-) muss vor jedem Schweiß auf jedes Hybrid ausgerüstetes Fahrzeug getrennt werden.
Vorsicht: Folgen Sie das festgelegte Verfahren in der angegebenen Reihenfolge Gerätefehlfunktionen oder Schäden zu vermeiden.
Vorsicht: Sie nicht die Feststellbremse lösen oder versuchen, einen Gang einzulegen, bis der Luftdruck auf dem richtigen Niveau ist.
Vorsicht: Um eine Beschädigung des Getriebes beim Abschleppen Ort des Schalthebels in „N“ und heben die Antriebsräder vom Boden zu vermeiden oder den Antriebsstrang trennen.
Hochspannungs-Warnungen & Verwarnungen
- Verwenden CO2 oder Trockenlöschmittel.
- Die Hochspannungsverdrahtung in orange Isolierung oder Wellrohr eingeschlossen und mit einer Warnetikett an den Anschlüssen bedeckt.
- Alle Eaton® Hybrid Diesel / Elektrofahrzeuge gekennzeichnet sein wird ‚Hybrid’ auf der Außenseite des Fahrzeugs, zusammen mit dem Schiebeschild auf dem Armaturenbrett.
- Siehe OEM für bestimmte Lage von Chassis montiert Hybridkomponenten.
- Nicht in die orangefarbenen Hochspannungskabel geschnitten.
- Schneiden Sie nicht in oder öffnen Sie die PEC.
- Schneiden Sie nicht in oder öffnen Sie die DC / DC-Wandler.
- Schneiden Sie nicht in der oder den Frequenzumrichter öffnen.
Eine Pufferzone muss und hochspannungsisoliertem Gummihandschuhen festgelegt werden (Klasse 0 mit Lederprotektoren) vor der Arbeit an Hochspannung ist erforderlich,. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Die gummiisolierte Handschuhe, die während der Arbeit an der Hochspannungsanlage sind Klasse getragen werden müssen 0 mit Lederprotektoren. Die Gummihandschuhe sollten in „Diagnose-Tools / Service Publikationen“ auf Seite gefunden im Anschluss an die Gummiisolierung Handschuhe Prüfvorgang vor jedem Einsatz getestet werden 6. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Vor Inspektion oder Arbeiten an allen Hochspannungskabeln oder Komponenten, die das „High-Voltage-Service Shutdown und Power-Up-Verfahrens“ auf Seite 4 sollte folgen. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Die Lockout und Tagout Geräte sollten nur durch den Techniker entfernt werden, der die Sperre und Tagout Vorrichtungen am Fahrzeug platziert. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Hochspannungs-Gummi-isolierte Handschuhe (Klasse 0 mit Lederprotektoren) muss getragen werden, wenn auf jedem Arbeits
Hochspannungskabel. Das „High-Voltage-Service Shutdown und Power-Up-Verfahren“ auf Seite 4 muss vor dem Entfernen aller Hochspannungskabel anschließen. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Hochspannungs-Kabel und Leitungen sind orange und enthalten einen Warnhinweis an den Anschlüssen. Hochvolt-Komponenten sind mit einem Aufkleber gekennzeichnet. Hochspannungs-Gummi-isolierte Handschuhe (Klasse 0 mit Lederprotektoren) muss verwendet werden, wenn sie auf eine dieser Komponenten arbeiten. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Hochspannungs-Service-Shutdown-Verfahren
1. Folgen Sie „Hochspannungs-Arbeitsbereich“ Verfahren.
2. Suchen Sie den roten PEC Service Switch auf der Vorderseite des PEC und drücken ausschalten.
3. Entfernen Sie die Service-Schalterabdeckung und installieren Sie den Lockout Bracket (J48506).
4. Befestigen Tag an den Lockout Bracket.
5. Sicherstellen, dass die PEC Service Switch kann nicht von der Aus-Position bewegen.
6. Das System kann für ein Minimum einzustellen von 5 Minuten Hochspannung zu entladen,.
7. Schließen Sie den Serviceranger und Data Monitor PID anzuzeigen 116 „Hochspannungs-Batteriepotential“ genannt. Die Nutzung SPN 520323 „Batteriespannung RB“ für J1939-Anschluss (Relais-Box).
8. Die Spannung sollte sein 30 Volt oder weniger. Wenn die Spannung über 30 Volt, funktioniert nicht auf dem Fahrzeug und kontaktiert Eaton® bei 1-800-826-HELP (4357).
9. Die Zündschlüssel ab und gehen Sie zu reparieren oder Problem Schritt.
Hinweis: Die Spannung fällt auf Null, wenn der Schlüssel ausgeschaltet ist.
Hochspannungs-Service-Power-Up Verfahren
1. Installieren aller Hochspannungs-Steckverbinder in ihre verriegelten Stellungen.
2. Wenn Sie die Person, die Arbeit am Fahrzeug sind, Entfernen Sie den Lockout Bracket und Tag.
3. Setzen Sie die Lockout Halterung über den Service Switch.
4. Ziehen Sie den Service-Schalter und lassen Fahrzeug Set für 2 Protokoll.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Komponenten und Stecker-Position ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Komponenten und Steckverbinder Standort MY09 Systeme” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”SCHRITT 1. Überprüfen Sie, ob aktiv oder inaktiv Fehlercode Status und Elektrischen Pretest” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Weiterlesen” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Überprüfen Sie und folgen Sie den Warnungen & Verwarnungen.
- Rufen Sie aktive Fehlercodes und FMI mit Serviceranger unter Verwendung der 9-Wege-Diagnosestecker oder manuell.
- Führen Sie die elektrische Pretest:
- Wenn keine Probleme bei dem elektrischen Vortest gefunden, gehen Sie zu Schritt 2.
- Wenn das Problem wurde während der Elektro Pretest repariert, Test abgeschlossen. Weiter mit Schritt 5.
[/fusion_content_box][fusion_content_box title=”SCHRITT 2. Stellen Sie sicher, FMI vorhanden.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Rufen Sie aktive Fehlercodes und FMI mit Serviceranger unter Verwendung der 9-Wege-Diagnosestecker oder manuell.
- Schlüssel aus.
Achtung: Sehen Hochspannungs-Service-Shutdown und Power-Up Verfahren. Folgen Sie den Anweisungen Schock zu vermeiden, verbrennen oder Tod durch unsachgemäß behandelt Hochspannungs-. - Welche FMIs vorhanden sind?
- wenn FMI 1 ist aufgelistet, ersetzen Sie den Inverter.
- Wenn Fehlercode 114 IWF 3 oder 4 ist aufgelistet, gehen Sie zu Schritt 3.
- Wenn Fehlercode 114 ist nicht hier, Test abgeschlossen. Weiter mit Schritt 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”SCHRITT 3. Verify Spannung am Inverter.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Schlüssel aus.
- Den Wechselrichter 56-poligen Stecker (MY08) 40-Way-Anschluss (MY09).
- Ein Multimeter an den Inverter 56-poligen Stecker Pin 15 und Pin 1 (MY08) 40-Way Stecker 1 und Pin 6. (MY09).
- Platz Multi wo es angezeigt werden, während neben dem LKW stehen.
- Key auf.
- Beachten Sie Multimeter Spannungsmessung:
Hinweis: Gently flex the Inverter 56-Way Connector Harness near the connector while monitoring the voltage reading.- Wenn die Spannung 11-13 Volt (auf einem 12-Volt-System) oder 23- 25 Volt (auf einem 24-Volt-System), ersetzen Sie den Inverter, dann weiter mit Schritt 5.
- Wenn die Spannung größer als 16 Volt (auf einem 12-Volt-System) oder 32 Volt (auf einem 24-Volt-System), Reparatur des Fahrzeugs 12-Volt-Ladesystem. Wenden Sie sich an den OEM für Reparaturverfahren.
- Wenn die Spannung außerhalb des Bereichs liegt, gehen Sie zu Schritt 4.
[/fusion_content_box][fusion_content_box title=”SCHRITT 4. Überprüfen Sie die Kontinuität der Schaltungen zwischen HCM Harness und Inverter.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Schlüssel aus.
- Trennen Sie das negative Batteriekabel.
- Trennen Sie das HCM-System Harness 38- poliger Stecker.
- Messen Sie den Widerstand aus der folgenden:
- Inverter 56-poliger Stecker Pin 15 to HCM 38- Way Stecker 2 (MY08). Inverter 40-Way Connector Pin 1 to HCM 38-Way Connector Pin 2 (MY09).
- Inverter 56-poliger Stecker Pin 1 grundieren (MY08) Inverter 40-Way Connector Pin 6 grundieren (MY09).
- Wenn der Widerstand von Pin 15 anheften 2 (MY08) oder Pin 1 anheften 2 (MY09) ist 0 zu 0.3 Ohm und Widerstand von Pin 1 zu Boden 0 zu 0.3 Ohm, ersetzen Sie das Modul Hybrid Control (HCM). Weiter mit Schritt 5.
- Wenn der Widerstand außerhalb des Bereichs liegt, die Unterbrechung der Strom- oder Masse Harness, dann weiter mit Schritt 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”SCHRITT 5. Reparatur überprüfen.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Weiterlesen” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Schlüssel aus.
- Schließen Sie alle Anschlüsse und die negativen Batteriekabel.
- Key auf.
- Codes löschen, sehen Klar Inaktive Fehler.
- Fahren Sie das Fahrzeug und versuchen, den Code neu.
- Prüfen Sie, ob Codes, sehen Sehen Sie Aktive und inaktive Fehler.
- Wenn keine Codes, Test abgeschlossen.
- Wenn der Fehler-Code 114 erscheint, finden Fehler bei der Prüfung, gehen Sie zu Schritt 1.
- Wenn ein anderer Code als 114 erscheint, sehen Fehlercode Indexliste.