[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybridgetriebe Fehlercode 112 – Inverter Spannung

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fehlercode für Eaton Hybrid Drive System Modelle (MY08) EH-U-8E306A, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P und EH-6E706B-UPG. Lesen Sie unten, um zu erfahren wie zu testen, löschen und Fehlercode Fehler für Ihre Freight beheben, Mack, Peterbilt, Kenworth, Volvo, International, schwere und schwere Lkw und Ausrüstung. Der Inverter ist mit der Leistungselektronik Träger (PEC) durch ein Hochspannungs-Gleichstromkabel, die Lieferungen 340 Volt von den Batterien. Während der Operation, der Wechselrichter überwacht die Eingangsspannung über oder unter eine Spannung Sorge um zu bestimmen,.

Falscher Code 112 – Inverter Spannungserkennung

Folgende Voraussetzungen müssen erfüllt sein, bevor das System den Fehler erkennt:

  • Inverter-Zündspannung größer ist als 7 Volt und weniger als 16 Volt.

Hinweis: Wenn Sie eine inaktive Code zur Fehlerbehebung finden Sie in der Produktdiagnosemodus (PDM)

Bedingungen setzen Fehlercode Aktiv

  • IWF 4 gesetzt, wenn die Wechselrichter-Eingangsspannung am Kondensator gemessen wird, weniger als 200 Volt 1 zweite, während die Hauptrelais auf der Relais-Box sind.
  • IWF 3 gesetzt, wenn die Wechselrichter-Eingangsspannung am Kondensator gemessen wird, größer ist als 435 Volt 0.05 FRAU.

Notlösung, wenn Fehlercode 112 die folgenden Bedingungen auftreten, eingestellt ist:

  • Bernstein „prüfen Hybrid“ Licht leuchtet.
  • Der Fehler wird in Hybrid-Steuermodul gespeichert (HCM) Erinnerung.
  • Inverter schaltet Hochspannungsnetz ab.
  • HCM weiterhin das Hybridfahrzeug in einem Modus nur mit Diesel zu steuern,.
  • Getriebe Standardwerte starten Gang 1..

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Bedingungen einzustellen Fehlercode Inaktive

Nur inaktive Fehler können von der Transmission Electronic Control Unit gelöscht werden (TECU) oder HCM Geschichte mit Serviceranger. Die TECU löscht automatisch die Fehler aus der Geschichte nach dem 200 Stunden und die HCM löscht automatisch die Fehler aus der Geschichte nach dem Fehler waren inaktiv für 200 Std.

Dieser Fehlercode kann durch eine der folgenden Bedingungen verursacht werden:

  • IWF 1, 3, 4
    • Wandler
    • PEC
    • DC-Hochspannungskabel

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Falscher Code 112 – Inverter Spannungsprüfung

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Identifizierung der Komponenten:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14634|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Hochspannungs-DC-Anschluss an PEC ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-DC-Connector-to-PEC.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Hochspannungs-DC-Anschluss an PEC

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14635|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Hochspannungs-DC-Anschluss Ansicht Yazaki-Anschluss” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-DC-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Hochspannungs-DC-Anschluss Ansicht Yazaki-Anschluss

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

HINWEIS: Siehe die Eaton Hybrid Komponenten und Stecker-Position für Connector Standorte in MY08-Systeme

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

HINWEIS: Siehe die Eaton Hybrid Komponenten und Stecker-Position für Connector Standorte in MY09-Systeme.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14636|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Inverter an PEC-Anschlüsse für Eaton Fuller Getriebe” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-connectors.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”Warnungen & Verwarnungen” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Achtung: Gefahr bedeutet, Sie schwer verletzt werden oder getötet, wenn nicht die angegebene Prozedur folgen.
Warnung: Warnung zeigt eine unmittelbare Gefahr, die zu schweren Verletzungen führen kann, wenn Sie die angegebenen Verfahren nicht folgen.
Vorsicht: Vorsicht bedeutet, Fahrzeug oder Sachschäden können auftreten, wenn Sie die angegebene Verfahren nicht folgen.

Hinweis: Hinweis kennzeichnet zusätzliche Details, die bei der Diagnose oder Reparatur eines Bauteils / System helfen werden.

Folgen Sie das festgelegte Verfahren in der angegebenen Reihenfolge um Verletzungen zu vermeiden:

1. Wenn die Hochspannungs-Kegel sind rund um das Fahrzeug und die Sperre auf dem PEC installiert, die einzige Person, die das Fahrzeug starten erlaubt sein soll, ist die Person, die die Aussperrung Tag unterzeichnet.
2. Vor dem Arbeiten an einem Fahrzeug oder Verlassen der Kabine, während der Motor läuft, Sie sollten den Schalthebel in „N“ legen Sie die Feststellbremse eingestellt, und blockieren die Räder.
3. Aus Sicherheitsgründen, immer in Eingriff mit den Betriebsbremsen vor Gangpositionen von „N“ zu der Auswahl
4. Vor dem Start ein Fahrzeug immer auf dem Fahrersitz sitzt, Auswahl von „N“ auf der Schaltsteuerung, und die Feststellbremsen.
5. Bei Fahrzeugen mit EPTO, der Motor und / oder
Motor / Generator kann in EPTO Modus starten. Sie keine Wartungsarbeiten durchführen oder auf Fahrzeug arbeiten, in diesem Modus.
6. 12-Volt Batterie-Plus (+) und negative (-) muss vor jedem Schweiß auf jedes Hybrid ausgerüstetes Fahrzeug getrennt werden.

Vorsicht: Folgen Sie das festgelegte Verfahren in der angegebenen Reihenfolge Gerätefehlfunktionen oder Schäden zu vermeiden.
Vorsicht: Sie nicht die Feststellbremse lösen oder versuchen, einen Gang einzulegen, bis der Luftdruck auf dem richtigen Niveau ist.
Vorsicht: Um eine Beschädigung des Getriebes beim Abschleppen Ort des Schalthebels in „N“ und heben die Antriebsräder vom Boden zu vermeiden oder den Antriebsstrang trennen.

Hochspannungs-Warnungen & Verwarnungen

  • Verwenden CO2 oder Trockenlöschmittel.
  • Die Hochspannungsverdrahtung in orange Isolierung oder Wellrohr eingeschlossen und mit einer Warnetikett an den Anschlüssen bedeckt.
  • Alle Eaton® Hybrid Diesel / Elektrofahrzeuge gekennzeichnet sein wird ‚Hybrid’ auf der Außenseite des Fahrzeugs, zusammen mit dem Schiebeschild auf dem Armaturenbrett.
  • Siehe OEM für bestimmte Lage von Chassis montiert Hybridkomponenten.
  • Nicht in die orangefarbenen Hochspannungskabel geschnitten.
  • Schneiden Sie nicht in oder öffnen Sie die PEC.
  • Schneiden Sie nicht in oder öffnen Sie die DC / DC-Wandler.
  • Schneiden Sie nicht in der oder den Frequenzumrichter öffnen.

Eine Pufferzone muss und hochspannungsisoliertem Gummihandschuhen festgelegt werden (Klasse 0 mit Lederprotektoren) vor der Arbeit an Hochspannung ist erforderlich,. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Die gummiisolierte Handschuhe, die während der Arbeit an der Hochspannungsanlage sind Klasse getragen werden müssen 0 mit Lederprotektoren. Die Gummihandschuhe sollten in „Diagnose-Tools / Service Publikationen“ auf Seite gefunden im Anschluss an die Gummiisolierung Handschuhe Prüfvorgang vor jedem Einsatz getestet werden 6. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Vor Inspektion oder Arbeiten an allen Hochspannungskabeln oder Komponenten, die das „High-Voltage-Service Shutdown und Power-Up-Verfahrens“ auf Seite 4 sollte folgen. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Die Lockout und Tagout Geräte sollten nur durch den Techniker entfernt werden, der die Sperre und Tagout Vorrichtungen am Fahrzeug platziert. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Hochspannungs-Gummi-isolierte Handschuhe (Klasse 0 mit Lederprotektoren) muss getragen werden, wenn auf jedem Arbeits
Hochspannungskabel. Das „High-Voltage-Service Shutdown und Power-Up-Verfahren“ auf Seite 4 muss vor dem Entfernen aller Hochspannungskabel anschließen. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.
Hochspannungs-Kabel und Leitungen sind orange und enthalten einen Warnhinweis an den Anschlüssen. Hochvolt-Komponenten sind mit einem Aufkleber gekennzeichnet. Hochspannungs-Gummi-isolierte Handschuhe (Klasse 0 mit Lederprotektoren) muss verwendet werden, wenn sie auf eine dieser Komponenten arbeiten. Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder zum Tod führt.

Hochspannungs-Service-Shutdown-Verfahren

Hochspannungs-Service-Shutdown und Power-Up Verfahren1. Folgen Sie „Hochspannungs-Arbeitsbereich“ Verfahren.
2. Suchen Sie den roten PEC Service Switch auf der Vorderseite des PEC und drücken ausschalten.
3. Entfernen Sie die Service-Schalterabdeckung und installieren Sie den Lockout Bracket (J48506).
4. Befestigen Tag an den Lockout Bracket.
5. Sicherstellen, dass die PEC Service Switch kann nicht von der Aus-Position bewegen.
6. Das System kann für ein Minimum einzustellen von 5 Minuten Hochspannung zu entladen,.
7. Schließen Sie den Serviceranger und Data Monitor PID anzuzeigen 116 „Hochspannungs-Batteriepotential“ genannt. Die Nutzung SPN 520323 „Batteriespannung RB“ für J1939-Anschluss (Relais-Box).
8. Die Spannung sollte sein 30 Volt oder weniger. Wenn die Spannung über 30 Volt, funktioniert nicht auf dem Fahrzeug und kontaktiert Eaton® bei 1-800-826-HELP (4357).
9. Die Zündschlüssel ab und gehen Sie zu reparieren oder Problem Schritt.
Hinweis: Die Spannung fällt auf Null, wenn der Schlüssel ausgeschaltet ist.

Hochspannungs-Service-Power-Up Verfahren

1. Installieren aller Hochspannungs-Steckverbinder in ihre verriegelten Stellungen.
2. Wenn Sie die Person, die Arbeit am Fahrzeug sind, Entfernen Sie den Lockout Bracket und Tag.
3. Setzen Sie die Lockout Halterung über den Service Switch.
4. Ziehen Sie den Service-Schalter und lassen Fahrzeug Set für 2 Protokoll.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Komponenten und Stecker-Position ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponenten und Steckverbinder Standorte MY08-Systeme

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Komponenten und Steckverbinder Standort MY09 Systeme” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponenten und Steckverbinder Standorte MY09-Systeme

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=SCHRITT 1. Überprüfen Sie, ob aktiv oder inaktiv Fehlercode Status und Elektrischen Pretest.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Weiterlesen” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Überprüfen Sie und folgen Sie den Warnungen & Verwarnungen.
  2. Schlüssel aus.
  3. Key auf.
  4. Rufen Sie aktive Fehlercodes und FMI mit Serviceranger den 9-Way Diagnosestecker mit.
    Achtung: Sehen Hochspannungs-Service-Shutdown und Power-Up Verfahren. Folgen Sie den Anweisungen Schock zu vermeiden, verbrennen oder Tod durch unsachgemäß behandelt Hochspannungs-.
  5. Welche Fehler sind vorhanden?
    • Wenn Fehlercode 112 IWF 3 ist aufgelistet, Eaton in Kontakt 1-800-826-HELP (4357).
    • Wenn Fehlercode 112 IWF 3 wird neben anderen Active Hybrid Fehlercodes aufgelistet 112, gehe zu "Sehen Sie Aktive und inaktive Fehler“.
    • Wenn Fehlercode 112 IWF 4 ist aufgelistet, gehen Sie zu Schritt 2.

[/fusion_content_box][fusion_content_box title=SCHRITT 2. Stellen Sie sicher, Kapazität von Inverter DC-Hochspannungs-Steckverbinder.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Weiterlesen” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Schlüssel aus.
  2. Trennen Sie den DC-Hochspannungsstecker am Wechselrichter.
  3. Stellen Sie das Multimeter auf uF Option.
    Achtung: Sehen Hochspannungs-Service-Shutdown und Power-Up Verfahren. Folgen Sie den Anweisungen Schock zu vermeiden, verbrennen oder Tod durch unsachgemäß behandelt Hochspannungs-.
  4. Legen Sie die Leitungen in die 2 Inverter DC-Hochspannungs Sockets sicherstellen, dass berühren die Fühler die Anschlüsse.
  5. Notieren Sie die Messung nach 2 Protokoll:
    • Wenn die uF Lesung ist 1104 uF-1656 uF bei 68 ° F (20 ° C), gehen Sie zu Schritt 3.
    • Wenn das Lesen uF außerhalb 1104 uF-1656 uF bei 68 ° F (20 ° C), ersetzen Sie den Inverter, dann weiter mit Schritt 4.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=SCHRITT 3. Überprüfen Sie die Kontinuität der Schaltungen auf dem DC-Kabel zwischen PEC und Inverter.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Schlüssel aus.
  2. Trennen Sie die DC-Hochspannung Stecker aus der PEC.
  3. Den Widerstand jeder Schaltung auf dem DC-Kabel von dem PEC-Anschluss an den Wechselrichter-Anschluss:
    • Wenn der Widerstand für jede Schaltung ist 1 Ohm oder weniger, ersetzen Sie den Inverter, dann weiter mit Schritt 4.
    • Wenn der Widerstand Bereich aus, den DC-Hochspannungskabel ersetzen, dann weiter mit Schritt 4.

[/fusion_content_box][fusion_content_box title=SCHRITT 4. Reparatur überprüfen.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Weiterlesen” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Schlüssel aus.
  2. Schließen Sie alle Anschlüsse und die negativen Batteriekabel.
  3. Key auf.
  4. Codes löschen, sehen Klar Inaktive Fehler.
  5. Fahren Sie das Fahrzeug und versuchen, den Code neu.
  6. Prüfen Sie, ob Codes, sehen Sehen Sie Aktive und inaktive Fehler.
    • Wenn keine Codes, Test abgeschlossen.
    • Wenn der Fehler-Code 112 erscheint, finden Fehler bei der Prüfung, gehen Sie zu Schritt 1.
    • Wenn ein anderer Code als 112 erscheint, sehen Fehlercode Indexliste.