[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller híbrido Código de Falha de Transmissão 95 – 12-Volt Cranking Relé
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
O código de falha para Eaton híbridos modelos Sistemas de Acionamento (MY08) EH-8E306A-L, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-t, EH-6E606B-CD, (MY09) EH-8E406A-L / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-t, EH-6E706B-CD, EH-6E706B-P e EH-6E706B-UPG. Leia abaixo para saber como testar, limpar e corrigir erros de código de falha para o seu Freightliner, Mack, Peterbilt, Kenworth, Volvo, Internacional, e caminhões e equipamentos pesados.
The 12-volt Cranking Relay is wired into the Hybrid Control Module (HCM) no lado da bobina do relê. Na chave na, HCM determina qual o método de iniciar a utilização quer de alta tensão do motor / gerador, ou o motor de arranque.
Se o HCM usa o motor / gerador para ligar o motor, a embraiagem está fechado, the 12-Volt Cranking Relay is de-energized, que desliga a energia da bateria principal de alimentação para o início Ativar Relé. If the HCM uses the standard engine starter, 12-Volt Cranking Relé é energizado fornecendo energia da bateria para a alimentação principal Iniciar Ativar Relé, que então alimenta o solenóide de partida.
Código de falha 95 – 12-Detecção Cranking Relé Volt
Os seguintes pré-requisitos devem ser atendidos antes que o sistema detecta a falha:
- Módulo de Controlo Híbrido (HCM) tensão de ignição é maior do que 7 volts e inferior 16 volts.
- a velocidade do motor é 0 RPM ou desconhecida.
Nota: Ao solucionar um código Inativo referem-se ao Modo de diagnóstico do produto (PDM)
Condições para definir Código falha ativa
- FMI 3 se o HCM detecta am aberto ou curto para VBATT no circuito de controle do 12-Volt Cranking Relay for 1 segundo ou maior.
- FMI 4 está definido se o HCM detecta um curto para a terra no circuito de controle do 12-Volt Cranking Relay for 1 segundo ou maior.
Fallback Quando Código de Falha 95 é definir as seguintes condições ocorrer:
- Âmbar “check híbridos” luz de.
- A falha é armazenado no módulo de Controlo Híbrido (HCM) memória.
- Se a falha define no arranque, o motor dê, desde que as baterias de alta tensão tem um estado de carga suficiente de (SOC).
- Se os conjuntos de falhas durante a condução, o veículo continuará a operar.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Condições para definir falha código inativo
Somente falhas inativos podem ser apagados da Unidade de Transmissão de Controle Eletrônico (TECU) ou a história HCM usando ServiceRanger. O TECU limpa automaticamente as falhas de história depois 200 horas eo HCM limpa automaticamente as falhas da história após a falha estiver inativo por 200 horas.
Este código de falha pode ser causada por qualquer um dos seguintes:
- FMI3, 4
- Arnês veículo de HCM a 12 volts de colocação em marcha de retransmissão
- 12-volts de colocação em marcha de retransmissão
- HCM
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Código de falha 95 – 12-Volt Relay Test Cranking
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identificação dos componentes:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”2_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Híbrida System Interface Connector” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Harness Ver Frente
(HCM – Híbrida System Interface Connector)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14063|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”interruptor do relé de transmissão Fuller” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Typical-Relay-Switch.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Interruptor do relé típico
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
NOTA: Consulte a Eaton Componente Híbrido e conector Localização para locais Connector em Sistemas MY08
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
NOTA: Consulte a Eaton Componente Híbrido e conector Localização para locais Connector em Sistemas MY09.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14543|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM CRANKING bateria Relé para a transmissão Eaton Fuller ” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-CRANKING-RELAY-BATTERY.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”avisos & precauções” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]perigo: Perigo indica que você será severamente ferido ou morto, se não seguir o procedimento indicado.
Aviso: Aviso indica um risco imediato, o que poderia resultar em ferimentos graves, se você não seguir o procedimento indicado.
Cuidado: Cuidado indica veículo ou danos materiais poderia ocorrer se você não seguir o procedimento indicado.
Nota: Nota indica detalhe adicional que irá auxiliar no diagnóstico ou reparo de um componente / sistema.
Siga os procedimentos especificados na ordem indicada para evitar ferimentos:
1. Se os cones de alta tensão estão ao redor do veículo e o bloqueio está instalado no PEC, a única pessoa que devem ser autorizados a ligar o veículo é a pessoa que assinou o Tag do fechamento.
2. Antes de trabalhar em um veículo ou sair da cabine, enquanto o motor está funcionando, você deve colocar a alavanca de mudança em “N” definir o freio de estacionamento, e bloquear as rodas.
3. Por razões de segurança, sempre envolver os freios de serviço antes de selecionar posições de marcha do “N.”
4. Antes de iniciar um veículo, sempre esteja sentado no assento do motorista, seleccionar “N” no controlo de deslocamento, e definir os freios de estacionamento.
5. Em veículos com EPTO, o motor e / ou
Motor / Gerador pode iniciar no modo EPTO. Nunca executar qualquer manutenção ou trabalhar em veículo, enquanto estiver neste modo.
6. 12-Volt bateria positivo (+) e negativo (-) deve ser desligado antes de qualquer solda em qualquer veículo híbrido equipado.
Cuidado: Seguir os procedimentos especificados na ordem indicada para evitar o mau funcionamento do equipamento ou danos.
Cuidado: Não solte o freio de estacionamento ou tentar selecionar uma marcha até que a pressão do ar está no nível correto.
Cuidado: Para evitar danos à transmissão durante o reboque lugar a alavanca de mudança de “N” e levantar as rodas de accionamento do chão ou desligue o sistema de transmissão.
Avisos de alta tensão & precauções
- Use CO2 ou pó químico Extintores.
- A cablagem de alta tensão é coberto no isolamento de laranja ou tubagem enrolada e marcados com etiquetas de aviso nos conectores.
- Todos os Eaton® híbrido diesel / veículos elétricos será marcado como ‘híbrido’ do lado de fora do veículo, juntamente com o rótulo mudança no traço.
- Referem-se a OEM para localização específica de componentes de chassis montado híbridos.
- Não cortar os cabos laranja de alta tensão.
- Não corte ou abrir o PEC.
- Não corte ou abrir o conversor DC / DC.
- Não corte ou abrir o inversor.
A zona de amortecimento tem de ser configurado e de alta tensão isolados luvas de borracha (classe 0 com protetores de couro) são necessários antes de trabalhar de alta tensão. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
As luvas com isolamento de borracha que deve ser usado durante a trabalhar no sistema de alta tensão são de classe 0 com protetores de couro. As luvas de borracha devem ser testados antes de cada uso seguindo o procedimento de borracha luvas de isolamento testes encontrado em “Ferramentas de diagnóstico / Publicações de Serviços”, na página 6. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
Antes de inspecionar ou trabalhando em todos os cabos de alta tensão ou componentes do “de alta tensão de desligamento Serviço e Power-Up Procedimento” na página 4 deve ser seguido. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
Os dispositivos de bloqueio e Etiquetagem só deve ser removido pelo técnico que colocou os dispositivos de bloqueio e Etiquetagem no veículo. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
borracha isolados luvas de alta tensão (classe 0 com protetores de couro) deve ser usado quando se trabalha em qualquer
cabos de alta tensão. O “desligamento de alta tensão de serviço e Power-Up Procedimento” na página 4 devem ser seguidas antes da remoção de quaisquer cabos de alta tensão. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
cabos de alta tensão e cabos são de cor laranja e contêm uma etiqueta de aviso nos conectores. componentes de alta tensão são marcados com um rótulo. borracha isolados luvas de alta tensão (classe 0 com protetores de couro) deve ser utilizado quando se trabalha em qualquer um desses componentes. O não cumprimento destas instruções pode resultar em ferimentos graves ou morte.
De alta tensão Procedimentos de encerramento de Serviço
1. Siga “High-Voltage Área de Trabalho” procedimento.
2. Localize o interruptor vermelho PEC serviço na parte da frente do PEC e empurre desligar.
3. Remova a tampa do interruptor de serviço e instalar o suporte de bloqueio (J48506).
4. tag fechamento para o suporte de bloqueio.
5. Verifique se o interruptor PEC serviço não pode passar da posição de desligado.
6. Permitir que o sistema definido para um mínimo de 5 minutos, a descarga de alta voltagem.
7. Ligue ServiceRanger e visualizar os dados do monitor PID 116 chamado de “alta tensão potencial da bateria.” Use SPN 520323 para conexão J1939 “Tensão RB bateria” (Box relé).
8. A tensão deverá ser 30 volts ou menos. Se a voltagem estiver acima 30 volts, não funcionam no veículo e entre em contato Eaton® em 1-800-826-HELP (4357).
9. Gire a chave de ignição fora e proceder à reparação ou etapa de solução.
Nota: A tensão cai para zero quando a chave está desligada.
Procedimento de alta tensão Serviço de Power-Up
1. Instalar todos os conectores de alta tensão para as suas posições travadas.
2. Se você é a pessoa que trabalha no veículo, Remova o suporte de bloqueio e tag.
3. Reinstalar o suporte de bloqueio sobre o Interruptor de Serviço.
4. Puxe o Serviço Ligue e deixe conjunto veículo para 2 minutos.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Componente Híbrido e conector Localização ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Componente Híbrido e conector Localização Sistemas MY09” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”DEGRAU 1. Verifique a operação de colocação em marcha de relé.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”consulte Mais informação” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Recuperar os códigos de falha ativos e SIGF com ServiceRanger usando o conector de diagnóstico 9-Way ou manualmente.
- Trocar o 12-Volt Cranking relé com outro relé e ver se os retornos de falha:
- Se a falha não voltar com novo relé, substituir 12 Volt Cranking Relé, em seguida, ir para a Etapa 6.
- Se a falha retorna com novo relé, vá para a Etapa 2.
[/fusion_content_box][fusion_content_box title=”DEGRAU 2. Verifique SIGF Present.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- SIGF que foram listados a partir do Passo 1?
Nota: The 12-Volt Cranking Relay must be wired according to Eaton® Hybrid requirements (Mostrado acima) para este teste para funcionar corretamente. Se ligados de forma diferente, consultar o OEM para esquemática fiação correta.- Se FMI 3 está listado, vá para a Etapa 3.
- Se FMI 4 está listado, vá para a Etapa 6.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”DEGRAU 3. Verifique a continuidade dos circuitos Vehicle Harness.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”consulte Mais informação” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off Key
- cabo negativo da bateria de desconexão.
- Desligue o HCM Harness 38-Way Connector.
- Medir a resistência entre o conector 38-Way HCM Veículo Arnês Pin 32 e Pin 4:
- Se a resistência entre o pino 32 e Pin 4 é 40-120 ohms, vá para a Etapa 4.
- Se a resistência se encontra fora do intervalo, reparar o arnês de veículos para um circuito aberto, em seguida, ir para a Etapa 6.
[/fusion_content_box][fusion_content_box title=”DEGRAU 4. Verifique se a tensão entre os circuitos Arnês veículo e solo.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Chave ligada.
- tensão medida entre o conector 38-Way HCM Arnês Pin 32 e chão a tecla:
- Se a tensão entre o pino 32 e a terra está 5 volts, substituir o Módulo de Controlo Híbrido (HCM) (somente se o código de falha é Ativo), em seguida, ir para a Etapa 6.
- Se a tensão entre o pino 32 e a terra está 12 volts, reparar a curto e VBATT na Harness, em seguida, ir para a Etapa 6.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”DEGRAU 5. Verifique se a tensão entre os circuitos Arnês veículo e solo.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off Key.
- cabo negativo da bateria de desconexão.
- Desligue o HCM Harness 38-Way Connector.
- tensão medida entre o conector 38-Way HCM Arnês Pin 32 e no solo:
- Se a tensão entre o pino 32 e moído é 10K ohms ou superior, substituir o Módulo de Controlo Híbrido (HCM) (somente se o código de falha é Ativo), em seguida, ir para a Etapa 6.
- Se a resistência se encontra fora do intervalo, reparar o Harness veículo por um curto para a terra, em seguida, ir para a Etapa 6.
[/fusion_content_box][fusion_content_box title=”DEGRAU 6. Verifique reparação.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”consulte Mais informação” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off Key.
- Volte a ligar todos os conectores e o cabo negativo da bateria.
- Chave ligada.
- códigos claros, Vejo Falhas inativos claras.
- Conduzir o veículo e tentar redefinir o código.
- Verifique se há códigos, Vejo Ver falhas ativas e inativas.
- Se nenhum código, teste está completo.
- Se o código de falha 95 aparece, encontrar erro no teste, vá para a Etapa 1.
- Se um código diferente 95 aparece, Vejo Falha Lista Índice de Código.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]