[fusion_builder_container hundred_percent=yeshundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Codice Guasto ibrida 24 – J1939 HCM Messaggio (TECU)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Codice anomalia per i modelli ibridi Sistemi di azionamento Eaton (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P e EH-6E706B-UPG. Il sistema di trasmissione Electronic Control (TECU) comunica con il modulo di controllo ibrido (HCM) il collegamento dati J1939 durante il funzionamento del veicolo per lo scambio di marcia richiesta e le informazioni del cambio correnti.

Codice anomalia 24 – J1939 HCM Messaggio (TECU) rivelazione

I seguenti requisiti devono essere soddisfatti prima che il sistema rileva il guasto:

  • tensione di accensione TECU è maggiore 7 volt e inferiore 16 volt.
  • Nessun guasto del collegamento dati J1939 attualmente attivo nella TECU.

Condizioni da impostare il codice guasto attivo

  • FMI 9 impostato quando il TECU non riesce a ricevere dati di trasmissione (come ad esempio una marcia richiesta) per 2 o più secondi dalla CMI, ed è ancora comunicare con altri moduli J1939.

Fallback quando il codice di errore 24 è impostato si verificano le seguenti condizioni:

  • Red “servizio” si illumina, e una “F” lampeggia sul display del cambio.
  • Guasto è memorizzato nella memoria TECU.
  • modalità operativa cambia alla modalità fallback AutoShift.
  • Se l'errore imposta all'accensione, il motore non gira.
  • Se gli insiemi di errore durante la guida, del veicolo in marcia corrente. Quando il veicolo si ferma la frizione si apre e rimane in questa posizione.
  • La spia color ambra "Verifica ibrido" potrebbe essere visualizzata sul cruscotto a causa di un'attivazione Codice anomalia 48.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Condizioni da Set Fault codice inattivo

Solo i difetti inattivi possono essere cancellati dalla storia TECU o HCM tramite ServiceRanger. La TECU cancella automaticamente gli errori della storia dopo 200 ore. Il HCM cancella automaticamente un guasto dalla storia dopo che è stato inattivo per 200 ore.

Questo codice di errore può essere causato da una delle seguenti:

  • FMI 9
    • J1939 Data Link
    • HCM

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Codice anomalia 24 – J1939 HCM Messaggio (TECU) Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Sistema di Identificazione dei componenti MY08:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14126|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Harness vista frontale TECU – Connettore di interfaccia del veicolo” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Harness-Front-View-TECU.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness vista frontale
TECU – Connettore di interfaccia del veicolo

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14061|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Harness vista frontale (HCM – Connettore di interfaccia del veicolo)” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness vista frontale
(HCM – Connettore di interfaccia del veicolo)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTA: Fare riferimento alla Eaton componente Hybrid e Posizione del connettore Per il connettore Località in MY08 Sistemi

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTA: Fare riferimento alla Eaton componente Hybrid e Posizione del connettore Per il connettore Località in MY09 Sistemi.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14163|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Connettore Eaton Fuller TECU HCM” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-TECU-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”Avvertenze & Precauzioni” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Pericolo: Pericolo indica che sarà gravemente feriti o uccisi se non seguire la procedura indicata.
avvertimento: Avviso indica un pericolo immediato, che potrebbe causare gravi lesioni personali se non si segue la procedura indicata.
Attenzione: Attenzione significa veicolo o danni potrebbero verificarsi se non si segue la procedura indicata.

Nota: Nota indica dettaglio aggiuntivo che sarà di aiuto nella diagnosi o la riparazione di un componente / sistema.

Seguire le procedure indicate nell'ordine indicato per evitare lesioni personali:

1. Se i coni di alta tensione sono intorno al veicolo e il blocco è installato sul PEC, l'unica persona che dovrebbe essere consentito di avviare il veicolo è la persona che ha firmato l'etichetta di blocco.
2. Prima di lavorare su un veicolo o di lasciare la cabina mentre il motore è in funzione, è necessario posizionare la leva del cambio in “N” impostare il freno di stazionamento, e bloccare le ruote.
3. Per ragioni di sicurezza, sempre impegnare i freni di servizio prima di selezionare posizioni del cambio da “N.”
4. Prima di iniziare un veicolo sempre essere seduto sul sedile del conducente, selezionare “N” a controllo di cambio, e impostare il freno di stazionamento.
5. In veicoli con EPTO, il motore e / o
Motore / generatore può avviare in modalità EPTO. Non effettuare qualsiasi intervento di manutenzione o di lavorare su veicoli, in questa modalità.
6. 12-Volt Positivo batteria (+) e negativo (-) deve essere scollegato prima di qualsiasi saldatura su qualsiasi veicolo ibrido equipaggiato.

Attenzione: Seguire le procedure indicate nell'ordine indicato per evitare malfunzionamenti o danni.
Attenzione: Non rilasciare il freno di stazionamento o tentare di selezionare una marcia fino a quando la pressione dell'aria è al livello corretto.
Attenzione: Per evitare danni al cambio durante il traino posto la leva del cambio in “N” e sollevare le ruote motrici dalla terra o scollegare la trasmissione.

Avvertenze alta tensione & Precauzioni

  • Utilizzare CO2 o Polvere chimica Estintori.
  • Il cablaggio ad alta tensione è coperto in isolamento arancione o tubi contorta e contrassegnato con etichette di avvertimento ai connettori.
  • Tutti i diesel / I veicoli elettrici ibridi Eaton® saranno marcati ‘ibrida’ all'esterno del veicolo, insieme all'etichetta del cambio sul cruscotto.
  • Fare riferimento a OEM per la posizione specifica di componenti ibridi telaio montato.
  • Non tagliare i cavi ad alta tensione di colore arancione.
  • NON tagliare o aprire la PEC.
  • Non tagliare o aprire il convertitore DC / DC.
  • Non tagliare o aprire l'inverter.

Una zona cuscinetto deve essere impostato e alta tensione isolati guanti di gomma (classe 0 con protezioni in pelle) sono necessarie prima di lavorare ad alta tensione. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.
I guanti isolati in gomma che devono essere indossati durante il lavoro sul sistema ad alta tensione sono di classe 0 con protezioni in pelle. I guanti di gomma dovrebbero essere testati prima di ogni uso seguendo la procedura di guanti di gomma isolanti test trovato in “Strumenti di diagnostica / Servizio Pubblicazioni” a pagina 6. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.
Prima di ispezionare o lavorare su tutti i cavi ad alta tensione o componenti “ad alta tensione servizio Spegnimento e Power-Up Procedura” a pagina 4 dovrebbe essere seguita. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.
I dispositivi di blocco e messa in sicurezza deve essere rimossi solo dal tecnico che ha messo i dispositivi di blocco e Tagout sul veicolo. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.
isolati in gomma guanti-alta tensione (classe 0 con protezioni in pelle) deve essere indossato quando si lavora su qualsiasi
cavi ad alta tensione. Il “Servizio Shutdown-alta tensione e Power-Up Procedura” a pagina 4 deve essere seguito prima di rimuovere i cavi ad alta tensione. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.
cavi ad alta tensione e cavi sono di colore arancione e contengono un'etichetta di avvertimento ai connettori. componenti ad alta tensione sono contrassegnate con un'etichetta. isolati in gomma guanti-alta tensione (classe 0 con protezioni in pelle) deve essere utilizzato quando si lavora su uno di questi componenti. La mancata osservanza di queste istruzioni può causare gravi lesioni personali o la morte.

-Alta tensione procedure di servizio arresto

Ad alta tensione servizio Arresto e procedura di accensione1. Seguire “Area di lavoro ad alta tensione” Procedura.
2. Individuare il rosso switch PEC Service sulla parte anteriore della PEC e spingere spegnere.
3. Rimuovere il Service Cover Switch e installare la staffa di blocco (J48506).
4. tag Fissare al blocco staffa.
5. Assicurarsi che l'interruttore PEC Il servizio non può muoversi dalla posizione di off.
6. Lasciare che il sistema di impostare per un minimo di 5 minuti a scarica ad alta tensione.
7. Collegare ServiceRanger e visualizzare il monitor PID dati 116 chiamato “potenziale ad alta tensione della batteria.” Usa SPN 520323 per il collegamento J1939 “Tensione della batteria RB” (Box Relay).
8. La tensione deve essere 30 volt o meno. Se la tensione supera 30 volt, non funzionano sul veicolo e contattare Eaton® al 1-800-826-AIUTO (4357).
9. Girare la chiave di accensione off e procedere alla riparazione o alla fase di risoluzione dei problemi.
Nota: La tensione scende a zero quando la chiave è spento.

Procedura ad alta tensione-Service Power-Up

1. Installare tutti i connettori ad alta tensione nelle loro posizioni bloccate.
2. Se sei la persona che lavora sul veicolo, rimuovere il blocco staffa e tag.
3. Reinstallare il blocco staffa sopra l'interruttore di servizio.
4. Estrarre il Service Switch fuori e lasciare set veicolo per 2 minuti.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton componente Hybrid e Posizione del connettore ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton componente Hybrid e connettore Sedi MY08 Sistemi

[/fusion_modal][fusion_modal name=component_location2title=”Eaton componente Hybrid e Posizione del connettore MY09 Sistemi” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton componente Hybrid e connettore Sedi MY09 Sistemi

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=PASSO 1. Controllare lo stato del codice di errore attivo o non attivo ed eseguire Pre-test elettrico.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Leggi di più” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Recupera i codici di errore attivi e IMF con ServiceRanger utilizzando il connettore diagnostico 9-Way.
  2. Eseguire il Pre-test elettrico.
    • Se non problemi rilevati durante il Pre-test elettrico, andare al passo 2.
    • Se il problema è stato riparato durante il Pre-test elettrico, andare al passo 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=PASSO 2. Verificare la continuità del cablaggio veicolo.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Leggi di più” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. oFF.
  2. cavo negativo della batteria disconnessione.
  3. Scollegare il cablaggio del veicolo HCM 38- Way connettore.
  4. Misurare la resistenza tra il cablaggio del veicolo HCM 38- Way pin del connettore 2 e Pin 3:
    Nota: Assicurarsi che il / Ohm Meter Volt è sulla scala adeguata (in giro 200 scala ohm).

    • Se la resistenza tra pin 2 e Pin 3 è tra 50-70 ohm, sostituire il modulo di controllo ibrido (HCM), quindi andare al passo 3.
    • Se la resistenza è al di fuori della gamma, riparazione collegamento J1939 dati Harness, quindi andare al passo 3.

[/fusion_content_box][fusion_content_box title=PASSO 3. Verifica di riparazionebackgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. oFF.
  2. Ricollegare tutti i connettori e cavo negativo della batteria.
  3. tasto su.
  4. codici liberi, vedere Azzera guasti inattivi.
  5. Guidare il veicolo e tentare di ripristinare il codice.
  6. Verificare la presenza di codici, vedere Visualizza Guasti attive e inattivi.
    • Se non ci sono i codici, test è completo.
    • Se codice di errore 24 appare, trovare l'errore in fase di test, andare al passo 1.
    • Se un codice diverso 24 appare, vedere Guasto Lista dei codici Indice.