[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller przekładnia hybrydowa kod usterki 116 – Przekaźniki wysokiego napięcia usterki – (systemy MY09)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Kod błędu dla Eaton modeli hybrydowych układów napędowych (MY09) EH 8E406A-E / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P i EH-6E706B-UPG. Przeczytaj poniżej, aby dowiedzieć się, jak testować, wyczyścić i naprawić błędy kod błędu dla Freightliner, Mack, Peterbilt, Kenworth, Volvo, Międzynarodowy, i ciężarówki i sprzęt ciężkich. Przekaźniki wysokiego napięcia są umieszczone wewnątrz Power
Elektronika Carrier (PEC) w jednostce Relay Box. Po dodatniej stronie znajduje się jeden przekaźnik ładowania wstępnego, dodatkowy przekaźnik na plusie, i na minusie w sumie trzy przekaźniki. Przekaźniki te są normalnie otwarte, gdy system jest wyłączony. Przekaźniki są sterowane przez falownik.

Kod błędu 116 – Przekaźniki wysokiego napięcia wykrywania usterek

Następujące warunki muszą być spełnione, zanim system wykryje usterkę:

  • Napięcie zapłonu falownika jest większa niż 7 wolt i niższego 16 woltów.

Uwaga: Podczas rozwiązywania kod Nieaktywne odnoszą się do Tryb diagnostyczny produktu (PDM)

Ustaw warunki do aktywnego kodu usterki

  • MFW 3 jest ustawiony, gdy zwarcie do 12 V wykrywa się po stronie sterowania przekaźnika wysokiego napięcia.
  • MFW 4 jest ustawiony podczas zwarcia do ziemi jest wykrywany po stronie sterowania przekaźnika wysokiego napięcia.
  • MFW 5 i FMI 10 są otwarte, gdy obwód jest wykrywany na stronie sterowania przekaźnika wysokiego napięcia.
  • MFW 7 i FMI 14 tworzy się, gdy główny przekaźnik jest ujemny, a spadek napięcia przetwornicy kondensatora jest mniejsza niż 10-V / 5 sekund, gdy napięcie początkowe kondensatora jest większa niż 200 woltów.

Awaryjna, gdy kod usterki 116 jest ustawiony wystąpić następujące warunki:

  • Amber „Check Hybrid” światło świeci.
  • Blad jest przechowywany w module sterowania hybrydowego (HCM) pamięć.
  • Układ hybrydowy będzie nieaktywny.
  • Skrzynia biegów domyślnie ustawia bieg początkowy na 1. w trybie tylko oleju napędowego.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Ustaw warunki do błędu kod nieaktywny

Tylko nieaktywnych błędy mogą zostać usunięte z historii Tecu lub HCM przy użyciu ServiceRanger. TECU automatycznie usuwa usterki z historii po 200 godziny. HCM automatycznie usuwa usterki z historii po tym winy jest nieaktywna 200 godziny.

Ten kod błędu może być spowodowane przez jedną z następujących czynności::

  • MFW 3, 4, 5, 7, 10, 14
    • Napięcie drutu Odpowiedź z przetwornicy DC / DC do HCM
  • MFW 4
    • przekaźnik Box
    • Przełącznik inercja
    • falownik
    • Wiązka przewodów pojazdu między falownikiem a PEC
    • Głównym wysokiego napięcia obsługa Bezpiecznik jest przepalony lub brakujące
    • DC wysokiego napięcia Kabel blokady
    • PEC Red Button Przełącznik serwisowy

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Kod błędu 116 – Przekaźniki wysokiego napięcia test Fault

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Identyfikacja elementów:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14476|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40 stykowe złącze krycia widok falownika niskiego napięcia” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Duetsch 40 sposób widok łącznika dopełniającego
(Przetwornica złącze niskiego napięcia)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Kojarzenie widoku złącze Deutsch 19 sposobem ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Kojarzenie widok złącza
(Deutsch złącze 19 sposobem)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

UWAGA: Odnoszą się do Eaton Hybrid i lokalizacja złącza komponentowego dla złączy w MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14672|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Falownik do PEC MY09 Systems” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”ostrzeżenia & Przestrogi” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Zagrożenie: Niebezpieczeństwo wskazuje zostaniesz poważnie ranny lub zabity, jeśli nie postępować zgodnie z procedurą wskazaną.
Ostrzeżenie: Ostrzeżenie wskazuje na bezpośrednie zagrożenie, które mogłyby doprowadzić do poważnych obrażeń, jeśli nie postępować zgodnie z procedurą wskazaną.
Uwaga: Ostrzeżenie wskazuje pojazdu lub uszkodzenia mienia może nastąpić, jeśli nie postępować zgodnie z procedurą wskazaną.

Uwaga: Uwaga wskazuje dodatkowe szczegóły, które pomogą w diagnozie lub naprawy systemu komponentowego /.

Postępuj według określonych procedur w podanej kolejności, aby uniknąć zranienia:

1. Jeśli stożki wysokiego napięcia są wokół pojazdu, a blokada jest zainstalowany na PEC, jedyną osobą, która powinna mieć możliwość uruchomienia pojazdu jest osoba, która podpisała znacznik blokady.
2. Przed rozpoczęciem pracy w pojeździe lub opuszczania kabiny, gdy silnik jest uruchomiony, należy ustawić dźwignię zmiany biegów w „N” zaciągnąć hamulec postojowy, i zablokować koła.
3. Z powodów bezpieczeństwa, zawsze angażować hamulców przed wybraniu pozycji biegów od „N.”
4. Przed uruchomieniem pojazdu należy zawsze siedzącej w fotelu kierowcy, wybierz „N” w sprawie kontroli zmianowym, i ustawić hamulce postojowe.
5. W przypadku pojazdów z EPTO, silnik i / lub
Silnik / generator można uruchomić w trybie EPTO. Nigdy nie wykonywać żadnych prac konserwacyjnych lub na pojeździe, w tym trybie.
6. 12-Volt Battery pozytywny (+) i negatywne (-) musi być odłączony przed jakimkolwiek spawania na każdym Hybrid wyposażony pojazd.

Uwaga: Postępuj według określonych procedur w podanej kolejności, aby uniknąć uszkodzenia sprzętu lub obrażenia.
Uwaga: Nie zwolnić hamulec postojowy lub próbować wybrać bieg, aż ciśnienie powietrza jest na właściwym poziomie.
Uwaga: Aby uniknąć uszkodzenia przekładni podczas holowania ustawić dźwignię zmiany biegów w „n” i unieść koła napędowe z ziemi lub odłączyć układ napędowy.

Ostrzeżenia wysokiego napięcia & Przestrogi

  • Używać CO2 lub suche chemiczne Gaśnice.
  • Przewody wysokiego napięcia jest pokryta izolacją w kolorze pomarańczowym lub pokrętny rurek i oznaczone etykietami ostrzegawczymi na złączach.
  • Wszystkie Eaton® hybrydowy diesel / Pojazdy elektryczne będą oznaczone „Hybrid’ na zewnątrz pojazdu, wraz z etykietą zmianowym na desce rozdzielczej.
  • Patrz OEM dla określonego położenia podwozia zamontowane komponentów hybrydowych.
  • NIE pokroić pomarańczowych przewodów wysokiego napięcia.
  • NIE pokroić lub otworzyć PEC.
  • NIE pokroić lub otworzyć konwerter DC / DC.
  • NIE pokroić lub otworzyć falownik.

Strefa buforowa musi być ustawiony i wysokiego napięcia z izolacją rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) są wymagane przed pracuje na wysokim napięciu. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Rękawice gumowe-izolacyjne, które należy nosić podczas pracy przy instalacji wysokiego napięcia są klasą 0 ze skórzanymi ochraniaczami. Rękawice gumowe powinny być badane przed każdym użyciem, zgodnie z procedurą gumowe rękawice izolacyjne testowania znaleźć w „Narzędzia diagnostyczne / publikacje serwisowe” na stronie 6. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Przed sprawdzeniem lub pracujących na wszelkich przewodów lub elementów wysokiego napięcia z „High-Voltage Shutdown Obsługa i Power-Up procedury” na stronie 4 powinny być przestrzegane. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Urządzenia Lockout i Tagout powinna być usunięta tylko przez technika, który umieszczony urządzeń Lockout i Tagout na pojeździe. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Wysokiego napięcia izolowane rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) należy nosić podczas pracy na dowolny
Kable wysokiego napięcia. „High-Voltage Shutdown Obsługa i Power-Up Procedura” na stronie 4 Należy następnie przed usuwania kabli wysokiego napięcia. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Kable wysokiego napięcia i przewody są pomarańczowe i zawierają tabliczkę ostrzegawczą na złączach. elementy wysokonapięciowe są oznaczone etykietą. Wysokiego napięcia izolowane rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) muszą być stosowane podczas pracy na którykolwiek z tych składników. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.

Wysokiego napięcia wyłączenia usługi Procedury

Wysokiego napięcia Shutdown Obsługa i Power-Up Procedura1. Postępuj zgodnie z „High-Voltage Obszar roboczy” procedura.
2. Zlokalizuj czerwony przełącznik PEC serwisowa w przedniej części PEC i wcisnąć wyłączyć.
3. Zdejmij pokrywę wyłącznik serwisowy i zainstalować wspornik Lockout (J48506).
4. Zapiąć tag Blokada Wspornik.
5. Upewnić się, że przełącznik PEC usługa nie może przejść z pozycji wyłączonej.
6. Aby system mógł ustawić na minimum 5 minuty do rozładowania wysokim napięciem.
7. Podłączyć ServiceRanger i wyświetlić dane monitorowania PID 116 zwane „High-Voltage Potencjał akumulatora.” Use SPN 520323 połączenie J1939 „Napięcie akumulatora RB” (przekaźnik Box).
8. Napięcie powinno być 30 V lub mniej. Jeśli napięcie jest powyżej 30 woltów, nie działają na pojeździe i skontaktować Eaton® na 1-800-826-HELP (4357).
9. Obrócić kluczyk wyłączyć i przystąpić do naprawy lub etap rozwiązywania problemów.
Uwaga: Napięcie spada do zera, gdy klucz jest wyłączony.

Procedura wysokiego napięcia obsługa Power-Up

1. Zainstalować wszystkie złącza wysokiego napięcia w ich położeniach zamkniętych.
2. Jeśli jesteś osobą pracującą na pojeździe, usunąć blokadę wspornika i tag.
3. Ponownie zainstaluj Blokada Wspornik nad wyłącznik serwisowy.
4. Pociągnąć Switch Service i pozwól zestaw dla pojazdów 2 minuty.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid i lokalizacja złącza komponentowego ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent i złączy MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Komponent i lokalizacja Złącze MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent i złączy MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 1.Verify FMIs obecny.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Oceń i wykonaj ostrzeżenia & Przestrogi.
  2. Odzyskaj Aktywne kody błędów i FMIs z ServiceRanger użyciu złącze diagnostyczne 9-Way.
  3. Korzystanie ServiceRanger, Odczyty rekord w „Monitor Danych” pod J1939 Dane akumulatora HV: Parametr 520250 HV Battery1 potencjał napięcia i parametr 520323 Napięcie akumulatora RB. Obserwować napięcie na baterii Napięcie RB podczas kluczem na schodach i napięcia rekord jeśli istnieją.
  4. Które są obecne FMIs?
    • Jeśli kod błędu 116 MFW 3 znajduje się na liście, przejdź do kroku 2.
    • Jeśli kod błędu 116 MFW 4 znajduje się na liście, przejdź do kroku 4.
    • Jeśli kod błędu 116 MFW 5 lub 10 znajduje się na liście, przejdź do kroku 6.
    • Jeśli kod błędu 116 MFW 7 znajduje się na liście, przejdź do kroku 13.

[/fusion_content_box][fusion_content_box title=KROK 2. zweryfikować naprawy.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off, czekać 1 minuta.
  2. Odłączyć 40-Way Prostownik Connector.
  3. na klucz (zostanie ustawiony kod błędu 88, jasne usterki po naprawie).
  4. Uprząż na Pojazdów, sprawdzić za wszelkie napięcia na kołkach 21, 31, 22, 32, 23 i 33 do ziemi:
    • W przypadku stwierdzenia napięcia, usunąć 19-stykowe złącze na PEC i sprawdź napięcia na przetworniku 40-Pin, Następnie przejdź do kroku 3.
    • Jeśli napięcie jest wciąż obecny, naprawa pojazdu między falownikiem a 40-Pin, Następnie przejdź do kroku 3.
    • Jeśli napięcie jest zniknął, przejdź do kroku 3

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 3. Sprawdzenie ciągłości obwodów Connector PEC do masy.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. 1. Key off.
    2. Odłączyć PEC 19-stykowe złącze (Przełącznik czerwony usługi powinny być nadal wyciągnięta).
    3. Zmierzyć oporność na następujących zacisków 19-pinowe złącze:

    • Kołek 9 przypiąć 6 a Pin 9 przypiąć 12
    • Kołek 13 przypiąć 6 a Pin 13 przypiąć 12
    • Kołek 17 przypiąć 6 a Pin 17 przypiąć 12
      • Jeśli obwód otwarty, przejdź do kroku 2.
      • Jeżeli opór znajduje, wymienić skrzynkę przekaźnikową, Następnie przejdź do kroku 14.

[/fusion_content_box][fusion_content_box title=KROK 4. Sprawdzenie ciągłości obwodów falownika Connector.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Odłączyć falownik 40-stykowe złącze (19-Złącze sposób na PEC powinien być połączony z wyłącznikiem czerwony Służby wyciągnięta).
  3. Uprząż na Pojazdów, sprawdzić pod względem odporności na ziemi na pin 21 do ziemi, Kołek 22 do ziemi i PIN 23 do ziemi:
    • Jeśli jakikolwiek opór ze złączy przetwornicy ziemi znajduje, odłączyć PEC 19-stykowe złącze i ponownie sprawdzić OEM 40-stykowe złącze.
    • Jeśli rezystancja jest jeszcze znaleźć z 19-Way odłączony, naprawy wiązki przewodów pojazdu, Następnie przejdź do kroku 14.
    • Jeśli opór jest już z 19-Way odłączony, przejdź do kroku 5.
    • Jeśli odczyty liczników OL lub obwód otwarty, wymień falownik, Następnie przejdź do kroku 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 5. Sprawdzenie ciągłości obwodów Connector PEC do masy.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Odłączyć PEC 19-stykowe złącze.
  3. Na PEC 19-stykowe złącze, zmierzyć:
    • Kołek 9, Kołek 13 a Pin 17 do ziemi
    • Kołek 9 przypiąć 7, Kołek 9 przypiąć 10, Kołek 9 Montaż do PEC Stud
    • Kołek 13 przypiąć 7, Kołek 13 przypiąć 14, Kołek 13 Montaż do PEC Stud
    • Kołek 17 przypiąć 7, Kołek 17 przypiąć 14, Kołek 17 Montaż do PEC Stud
      • Jeżeli opór znajduje się od PEC Pins do masy, wymienić skrzynkę przekaźnikową. Zobacz usunięciu MY09 PEC wysokiego napięcia Skrzynka przekaźników i procedurę instalacji w TRSM2000, Następnie przejdź do kroku 14.
      • Jeśli odczyty liczników OL, wymagane jest przeprowadzenie ponownych badań, przejdź do kroku 4.

[/fusion_content_box][fusion_content_box title=KROK 6. Sprawdzenie ciągłości obwodów Connector PEC.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Odłączyć PEC 19-stykowe złącze. (Przycisk czerwony obsługa na PEC powinien być wyciągnięty.)(Nie należy wykonywać jeszcze „Hybrid Shutdown procedury”.)
  3. Zmierzyć oporność na PEC Connector:
    • Kołek 9 przypiąć 11
    • Kołek 13 przypiąć 15
    • Kołek 17 przypiąć 19
      • Jeżeli opór między stykiem 9 a Pin 11, a Pin 13 przypiąć 15 mają po 33-37 om i opór Pin 17 przypiąć 19 jest 112-122 omów, przejdź do kroku 7.
      • Jeśli opór jest poza zasięgiem, zresetować przełącznik znajdujący się wewnątrz otworu Inertia filtra powietrza lub w tylnym panelu dostępu przez Wysokiego napięcia Bezpiecznik, Następnie przejdź do kroku 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 7. Sprawdź kabel wysokiego napięcia na kablu Interlock OEM.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Sprawdzić, czy przełącznik bezwładnościowy jest OK.
  2. Zmierzyć rezystancję blokada styki kabla OEM.
    Zagrożenie: Widzieć Wysokiego napięcia wyłączania zasilania-Serwis i procedur. Postępuj zgodnie z procedurami, aby uniknąć porażenia prądem, spalić lub śmierci z niewłaściwym wysokiego napięcia.

    • Jeśli opór jest 0-0,3 omów, wymienić skrzynkę przekaźnikową, Następnie przejdź do kroku 9.
    • Jeśli opór jest OL, Wymień kabel wysokiego napięcia DC, Następnie przejdź do kroku 8.

[/fusion_content_box][fusion_content_box title=KROK 8. Sprawdzenie ciągłości obwodów Connector PEC do masy.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Zmierzyć oporność na PEC Connector (czerwony Service Button Switch jest wyciągnięta):
    • Kołek 9 przypiąć 11
    • Kołek 17 przypiąć 19
      • Jeśli opór jest OL, wymienić skrzynkę przekaźnikową (Skontrolować okablowanie wchodząc Skrzynka przekaźników przed wymianą), Następnie przejdź do kroku 9.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 9. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Jeśli pojazd jest wyposażony w Elektrowni PEC Export, wykonać „High-Voltage Shutdown usług i Power-Up procedury” na stronie 4, następnie usunąć wysokonapięciowych DC / DC i / lub APG wysokonapięciowych kabel z PEC. Zainstalować interlock Caps razie dostępny:
    • Jeżeli pojazd nie jest wyposażony w moc Export, przejdź do kroku 11.

[/fusion_content_box][fusion_content_box title=KROK 10. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Po DC / DC i APG przewody wysokiego napięcia są usuwane, wyciągnij czerwony przełącznik serwisowy i podłącz 19- Złącze sposób na PEC.
  2. na klucz:
    • Jeśli kod błędu 116 / FMI 5 jest nadal aktywny, przejdź do kroku 12.
    • Jeśli kod błędu 116 / FMI 5 przepadło, przejdź do kroku 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 11. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Wtyk DC / DC i / lub kabli APG powrotem do PEC i upewnij się, że kod błędu 116 / FMI 5 jest nadal aktywny:
    • Jeśli nadal aktywny, przejdź do kroku 12.
    • jeśli jest nieaktywny, Przekaźniki pomocniczego wewnątrz PEC przyspawane. Wymień PEC. Zobacz Przewoźnika MY09 energii elektrycznej (PEC) Demontaż i montaż, Alternatywą Carrier Elektryczny (PEC) Demontaż i instalacja lub 4- Battery Electric Power Carrier (PEC) Procedury demontażu i instalacji w TRSM2000.
      Również, sprawdzić obwód przekaźnika pomocniczego pod kątem luźnych połączeń blokujących powodujących drgania przekaźnika pod obciążeniem, patrz Kod błędu 118 – Przekaźnik pomocniczy High Voltage Usterka obwodu sterującego dla opisu obwodów).
    • Po zakończeniu naprawy, przejdź do kroku 14.

[/fusion_content_box][fusion_content_box title=KROK 12. Sprawdzenie ciągłości obwodów falownika Connector. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Połącz PEC 19-stykowe złącze.
  2. Odłączyć falownik 40-stykowe złącze.
  3. Zmierzyć oporność na przetworniku 40-Way Terminal OEM Connector w następujących pinów:
    • Kołek 21 przypiąć 31
    • Kołek 22 przypiąć 32
    • Kołek 23 przypiąć 33
      • Jeżeli opór między stykiem 21 a Pin 31 wynosi 112-122 omów i opór Pin 22 przypiąć 32, a Pin 23 przypiąć 33 mają po 33-37 omów, wymień falownik (zobacz MY09 Prostownik Demontaż i montaż), Następnie przejdź do kroku 14.
      • Jeśli rezystancja jest poza zakresem, naprawy wiązki przewodów pojazdu między falownikiem a PEC, Następnie przejdź do kroku 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 13. Zmierzyć napięcie akumulatora.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Podłączyć ServiceRanger do diagnostyki złącze 9-Way w kabinie.
  2. Wybierz opcję „Monitor danych”.
  3. Zobacz następujące parametry na liście akumulatorów wysokiego napięcia:
    • HV baterii akumulatorów HV danych J1939:
      Parametr 520250 HV Battery1 Potencjalne napięcia i parametrów 520323 Napięcie akumulatora RB
    • Wciśnij czerwony przycisk serwisowy.
    • Jeśli odczyty napięcia na Battery1 Potencjalne napięcia i napięcie akumulatora RB są w 10 V siebie (Napięcie akumulatora RB powinna spaść 30 volt, gdy czerwony Przełącznik serwisowy został wciśnięty), wymienić skrzynkę przekaźnikową. Zobacz usunięciu MY09 PEC wysokiego napięcia Skrzynka przekaźników i procedurę instalacji w TRSM2000, Następnie przejdź do kroku 14.
      Uwaga: „High-Voltage Shutdown i usługi
      Widzieć Wysokiego napięcia wyłączania zasilania-Serwis i procedur musi być wykonane przed wyjęciem kabla wysokiego napięcia. (Jeśli głównym
      Przekaźniki wysokiego napięcia są przyspawane, wyjąć bezpiecznik wysokiego napięcia znajdujący się w tylnym panelu dostępu przed przystąpieniem do jakichkolwiek napraw).
    • Jeśli odczyty napięcia na Battery1 Potencjalne napięcia i napięcie akumulatora RB są większe niż 10 V siebie (Napięcie akumulatora RB powinna spaść 30 volt, gdy czerwony Przełącznik serwisowy został wciśnięty), wymień falownik, Następnie przejdź do kroku 14.

[/fusion_content_box][fusion_content_box title=KROK 14. zweryfikować naprawy.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Podłącz wszystkie złącza i ujemny przewód akumulatora.
  3. na klucz.
  4. kasowanie kodów, widzieć Pogodne Nieaktywne Usterki.
  5. Kierowania pojazdem i próba zresetowania kodu.
  6. Sprawdzić kody, widzieć Zobacz Usterki aktywnych i nieaktywnych.
    • Jeśli nie ma kodów, test jest kompletny.
    • Jeśli kod błędu 116 pojawia się, znaleźć błąd w testowaniu, przejdź do kroku 1.
    • Jeśli kod inny niż 116 pojawia się, widzieć Lista błędów Kod Index.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]