[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller przekładnia hybrydowa Hybrydowa wstępny test elektryczny

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Ten test należy wykonać przed diagnozowania pewnych konkretnych usterek hybrydowe. Test sprawdza jego zasilanie przetwornicy i Carrier Elektryczny (PEC).
Uwaga: Musisz wykonać wstępny test elektryczny Przed wykonaniem badania wstępnego hybrydowy elektryczny.
Uwaga: Test ten nazywa się w procedurach, gdzie jest to wymagane

Wykrywanie wstępnego testu elektrycznego

Nie ma procesu wykrywania specjalnie dla podstawowego zasilania elektrycznego; jednak, awarie tego typu są zazwyczaj wykrywane przez układ hybrydowy lub kierowcę jako inny rodzaj kodu usterki lub objawu.

Hybrydowy elektryczny wstępny test awaryjna

Utrata zasilania zapłonu powoduje, że system hybrydowy będzie działać. W tej sytuacji, pojazd będzie działać wyłącznie w ramach diesel moc.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Możliwe przyczyny wskazane przez Eaton Fuller przekładni hybrydowej Hybrid Elektrycznego przed badaniem

(MY08) Niskie napięcie może być spowodowane połączeniami wiązki przewodów zasilania z falownika lub modułu BCU.

(MY09) Niskiego napięcia mogą być spowodowane przez połączenia wiązki zasilania z falownika lub PEC.

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

MY08 Identyfikacja elementów dla Eaton Fuller przekładni hybrydowej Hybrid Elektrycznego przed badaniem:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14474|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Przetwornica 56-Way Gody Connector View” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-56-Way-Mating-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Przetwornica 56-Way Gody Connector View
(falownik – Złącze niskonapięciowe)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Deutsch 19 – Droga Gody Connector View” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Deutsch 19 – Droga Gody Connector View
(PEC – Złącze niskonapięciowe)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”” background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allborder_radius_top_left=”” border_radius_top_right=”” border_radius_bottom_left=”” border_radius_bottom_right=”” box_shadow=nobox_shadow_vertical=”” box_shadow_horizontal=”” box_shadow_blur=”0″ box_shadow_spread=”0″ box_shadow_color=”” box_shadow_style=”” padding_top=”” padding_right=”” padding_bottom=”10″ padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14906|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Falownik do lokalizacji PEC Eaton Fuller hybrydowego transmisja badania wstępnego elektrycznego” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-locations-Eaton-Fuller-transmission-hybrid-electrical-pretest-800×363.jpg[/fusion_imageframe][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14907|400″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”skrzynia biegów Eaton Fiuller DC do masy” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/DC-converter-to-ground-400×410.jpg[/fusion_imageframe][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14279|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Deutsch 4 stykowe OEM” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Deutsch-4-way-OEM-connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Konwerter DC / DC
4-Złącze sposób OEM

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

UWAGA: Odnoszą się do Eaton Hybrid i lokalizacja złącza komponentowego dla złączy w MY08 Systems

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

MY09 Identyfikacja elementów dla Eaton Fuller przekładni hybrydowej Hybrid Elektrycznego przed badaniem:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14476|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Deutsch 40-Way Gody Connector View” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Deutsch 40-Way Gody Connector View
(falownik – Złącze niskonapięciowe)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Deutsch 19 – Droga Gody Connector View” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Deutsch 19 – Droga Gody Connector View
(PEC – Złącze niskonapięciowe)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”” background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allborder_radius_top_left=”” border_radius_top_right=”” border_radius_bottom_left=”” border_radius_bottom_right=”” box_shadow=nobox_shadow_vertical=”” box_shadow_horizontal=”” box_shadow_blur=”” box_shadow_spread=”” box_shadow_color=”” box_shadow_style=”” padding_top=”” padding_right=”” padding_bottom=”10″ padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14908|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Falownik do lokalizacji PEC Eaton Fuller MY009 do wstępnego testu elektrycznego przekładni hybrydowej Eaton Fuller” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-locations-Eaton-Fuller-MY009-transmission-hybrid-electrical-pretest-800×385.jpg[/fusion_imageframe][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14907|400″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”skrzynia biegów Eaton Fiuller DC do masy” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/DC-converter-to-ground-400×410.jpg[/fusion_imageframe][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14279|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Deutsch 4 stykowe OEM” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Deutsch-4-way-OEM-connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Konwerter DC / DC
4-Złącze sposób OEM

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

UWAGA: Odnoszą się do Eaton Hybrid i lokalizacja złącza komponentowego dla złączy w MY09 Systems.

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”ostrzeżenia & Przestrogi” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Zagrożenie: Niebezpieczeństwo wskazuje zostaniesz poważnie ranny lub zabity, jeśli nie postępować zgodnie z procedurą wskazaną.
Ostrzeżenie: Ostrzeżenie wskazuje na bezpośrednie zagrożenie, które mogłyby doprowadzić do poważnych obrażeń, jeśli nie postępować zgodnie z procedurą wskazaną.
Uwaga: Ostrzeżenie wskazuje pojazdu lub uszkodzenia mienia może nastąpić, jeśli nie postępować zgodnie z procedurą wskazaną.

Uwaga: Uwaga wskazuje dodatkowe szczegóły, które pomogą w diagnozie lub naprawy systemu komponentowego /.

Postępuj według określonych procedur w podanej kolejności, aby uniknąć zranienia:

1. Jeśli stożki wysokiego napięcia są wokół pojazdu, a blokada jest zainstalowany na PEC, jedyną osobą, która powinna mieć możliwość uruchomienia pojazdu jest osoba, która podpisała znacznik blokady.
2. Przed rozpoczęciem pracy w pojeździe lub opuszczania kabiny, gdy silnik jest uruchomiony, należy ustawić dźwignię zmiany biegów w „N” zaciągnąć hamulec postojowy, i zablokować koła.
3. Z powodów bezpieczeństwa, zawsze angażować hamulców przed wybraniu pozycji biegów od „N.”
4. Przed uruchomieniem pojazdu należy zawsze siedzącej w fotelu kierowcy, wybierz „N” w sprawie kontroli zmianowym, i ustawić hamulce postojowe.
5. W przypadku pojazdów z EPTO, silnik i / lub
Silnik / generator można uruchomić w trybie EPTO. Nigdy nie wykonywać żadnych prac konserwacyjnych lub na pojeździe, w tym trybie.
6. 12-Volt Battery pozytywny (+) i negatywne (-) musi być odłączony przed jakimkolwiek spawania na każdym Hybrid wyposażony pojazd.

Uwaga: Postępuj według określonych procedur w podanej kolejności, aby uniknąć uszkodzenia sprzętu lub obrażenia.
Uwaga: Nie zwolnić hamulec postojowy lub próbować wybrać bieg, aż ciśnienie powietrza jest na właściwym poziomie.
Uwaga: Aby uniknąć uszkodzenia przekładni podczas holowania ustawić dźwignię zmiany biegów w „n” i unieść koła napędowe z ziemi lub odłączyć układ napędowy.

Ostrzeżenia wysokiego napięcia & Przestrogi

  • Używać CO2 lub suche chemiczne Gaśnice.
  • Przewody wysokiego napięcia jest pokryta izolacją w kolorze pomarańczowym lub pokrętny rurek i oznaczone etykietami ostrzegawczymi na złączach.
  • Wszystkie Eaton® hybrydowy diesel / Pojazdy elektryczne będą oznaczone „Hybrid’ na zewnątrz pojazdu, wraz z etykietą zmianowym na desce rozdzielczej.
  • Patrz OEM dla określonego położenia podwozia zamontowane komponentów hybrydowych.
  • NIE pokroić pomarańczowych przewodów wysokiego napięcia.
  • NIE pokroić lub otworzyć PEC.
  • NIE pokroić lub otworzyć konwerter DC / DC.
  • NIE pokroić lub otworzyć falownik.

Strefa buforowa musi być ustawiony i wysokiego napięcia z izolacją rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) są wymagane przed pracuje na wysokim napięciu. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Rękawice gumowe-izolacyjne, które należy nosić podczas pracy przy instalacji wysokiego napięcia są klasą 0 ze skórzanymi ochraniaczami. Rękawice gumowe powinny być badane przed każdym użyciem, zgodnie z procedurą gumowe rękawice izolacyjne testowania znaleźć w „Narzędzia diagnostyczne / publikacje serwisowe” na stronie 6. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Przed sprawdzeniem lub pracujących na wszelkich przewodów lub elementów wysokiego napięcia z „High-Voltage Shutdown Obsługa i Power-Up procedury” na stronie 4 powinny być przestrzegane. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Urządzenia Lockout i Tagout powinna być usunięta tylko przez technika, który umieszczony urządzeń Lockout i Tagout na pojeździe. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Wysokiego napięcia izolowane rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) należy nosić podczas pracy na dowolny
Kable wysokiego napięcia. „High-Voltage Shutdown Obsługa i Power-Up Procedura” na stronie 4 Należy następnie przed usuwania kabli wysokiego napięcia. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.
Kable wysokiego napięcia i przewody są pomarańczowe i zawierają tabliczkę ostrzegawczą na złączach. elementy wysokonapięciowe są oznaczone etykietą. Wysokiego napięcia izolowane rękawice gumowe (klasa 0 ze skórzanymi ochraniaczami) muszą być stosowane podczas pracy na którykolwiek z tych składników. Niezastosowanie się do tych zaleceń może doprowadzić do poważnych obrażeń lub śmierci.

Wysokiego napięcia wyłączenia usługi Procedury

Wysokiego napięcia Shutdown Obsługa i Power-Up Procedura1. Postępuj zgodnie z „High-Voltage Obszar roboczy” procedura.
2. Zlokalizuj czerwony przełącznik PEC serwisowa w przedniej części PEC i wcisnąć wyłączyć.
3. Zdejmij pokrywę wyłącznik serwisowy i zainstalować wspornik Lockout (J48506).
4. Zapiąć tag Blokada Wspornik.
5. Upewnić się, że przełącznik PEC usługa nie może przejść z pozycji wyłączonej.
6. Aby system mógł ustawić na minimum 5 minuty do rozładowania wysokim napięciem.
7. Podłączyć ServiceRanger i wyświetlić dane monitorowania PID 116 zwane „High-Voltage Potencjał akumulatora.” Use SPN 520323 połączenie J1939 „Napięcie akumulatora RB” (przekaźnik Box).
8. Napięcie powinno być 30 V lub mniej. Jeśli napięcie jest powyżej 30 woltów, nie działają na pojeździe i skontaktować Eaton® na 1-800-826-HELP (4357).
9. Obrócić kluczyk wyłączyć i przystąpić do naprawy lub etap rozwiązywania problemów.
Uwaga: Napięcie spada do zera, gdy klucz jest wyłączony.

Procedura wysokiego napięcia obsługa Power-Up

1. Zainstalować wszystkie złącza wysokiego napięcia w ich położeniach zamkniętych.
2. Jeśli jesteś osobą pracującą na pojeździe, usunąć blokadę wspornika i tag.
3. Ponownie zainstaluj Blokada Wspornik nad wyłącznik serwisowy.
4. Pociągnąć Switch Service i pozwól zestaw dla pojazdów 2 minuty.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid i lokalizacja złącza komponentowego ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent i złączy MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Komponent i lokalizacja Złącze MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent i złączy MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_max_width=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 1. Sprawdzenie ciągłości uziemienia przetwornicybackgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Przeprowadzić elektryczne przed badaniem, następnie kontynuować # 2.
  2. Key off.
  3. Odłączyć falownik 40-stykowe złącze.
    Zagrożenie: Widzieć Wysokiego napięcia wyłączania zasilania-Serwis i procedur. Postępuj zgodnie z procedurami, aby uniknąć porażenia prądem, spalić lub śmierci z niewłaściwym wysokiego napięcia.
  4. (MY08) Zmierzyć rezystancję między stykiem 1 do ujemnego akumulatora, a następnie z Pin 2 do bieguna ujemnego akumulatora:
    • Jeśli opór jest 0-0,3 omów z Pin 1 do bieguna ujemnego akumulatora oraz z Pin 2 do bieguna ujemnego akumulatora, przejdź do kroku 2.
    • Jeśli rezystancja jest poza zasięgiem, naprawy przetwornicy Parter Uprzęże. Powtórz ten krok.
      (MY09) Zmierzyć rezystancję między stykiem 6 do ujemnego akumulatora, a następnie z Pin 7 do bieguna ujemnego akumulatora:
    • Jeśli opór jest 0-0,3 omów z Pin 6 do bieguna ujemnego akumulatora oraz z Pin 7 do bieguna ujemnego akumulatora, przejdź do kroku 2.
    • Jeśli rezystancja jest poza zasięgiem, naprawy przetwornicy Parter Uprzęże. Powtórz ten krok.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_max_width=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 2. erify napięcie na złącze falownika. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. (MY08) Podłączyć multimetr do przetwornicy 56-stykowe Way 15 a Pin 1.
    (MY09)Podłączyć volt / metr ohm do falownika 40-Way stykowe 1 a Pin 6.
  2. na klucz.
  3. Obserwować napięcia odczyt Volt / Ohm Meter:
    • Jeśli napięcie 11-13 V, przejdź do kroku 3.
    • Jeśli napięcie jest poza zakresem, naprawić uprząż z HCM. Powtórz ten krok.

[/fusion_content_box][fusion_content_box title=KROK 3. Sprawdzenie ciągłości Inverter do PEC przewodu uziemienia. .backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Podłącz falownik 56-Way stykowe 15 & Kołek 1 (MY08) Przetwornica 40-stykowe złącze (MY09).
  3. Odłącz nośnik zasilania elektrycznego (PEC) 19- droga Connector.
  4. Zmierzyć opór PEC Pin 7 do bieguna ujemnego akumulatora.
    • Jeżeli opór Pin 7 do akumulatora ujemny jest 0-0,3 omów, przejdź do kroku D.
    • Jeśli rezystancja jest poza zasięgiem, naprawy falownika do PEC przewodu uziemienia. Powtórz ten krok.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_max_width=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 4. Sprawdzenie napięcia na PEC 19-stykowe złączebackgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”Czytaj więcej” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Podłączyć volt / om do PEC 19-stykowe Way 6 a Pin 7.
  2. na klucz.
  3. Obserwować V / napięcie czytania ohm.
    • Jeśli napięcie 11-13 V i pojazd posiada funkcję EPTO na Push Button, przejdź do kroku 5.
    • Jeśli napięcie 11-13 V i pojazd nie posiada funkcji EPTO, test jest kompletny. Podłącz PEC 19-stykowe złącze. Przejdź do „Kod błędu Procedura izolacji Index”.
    • Jeśli napięcie jest poza zakresem, naprawy przewodów zasilających z falownika. Powtórz ten krok.

[/fusion_content_box][fusion_content_box title=KROK 5. Sprawdzenie ciągłości DC / DC przewód uziemienia.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Podłącz PEC 19-stykowe złącze.
  3. Odłączyć konwerter DC / DC 4-pinowe złącze.
  4. Zmierzyć opór przetwornica DC / DC 4-Way stykowe 4 do bieguna ujemnego akumulatora:
    • Jeżeli opór między stykiem 4 i ujemny akumulatora jest 0-0,3 omów, test jest kompletny. Podłącz 4-pinowe złącze. Widzieć "Kod błędu Procedura izolacji Index”.
    • Jeśli rezystancja jest poza zasięgiem, naprawy ziemi Uprząż z przetwornicy DC / DC do ujemnego akumulatora, następnie powtórzyć ten krok.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]