[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller hybride transmissie Fault Code 116 – High Voltage Relais Fault – (MY09 systemen)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Storing code voor Eaton Hybrid Drive Systems modellen (MY09) EH-8E406A-E / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P en EH-6E706B-UPG. Lees hieronder om te leren hoe om te testen, wissen en bevestig foutcode fouten voor uw Freightliner, Mack, Peterbilt, Kenworth, Volvo, Internationale, en heavy-duty truck en apparatuur. De High-Voltage relais bevinden zich in de kracht
Electronics Carrier (PEC) in de relaiskast unit. There is one Pre-Charge Relay on the positive side, an additional relay on the positive, and on the negative for a total of three relays. Deze relais zijn normaal open wanneer het systeem is uitgeschakeld. De relais worden bestuurd door de inverter.

Fout code 116 – High Voltage Relais Storingsdetectie

De volgende randvoorwaarden moet worden voldaan voordat het systeem de fout detecteert:

  • Inverter ontsteekspanning groter is dan 7 volt en minder dan 16 volt.

Notitie: Bij het oplossen van een inactieve code wordt verwezen naar de Product Diagnostic Mode (PDM)

Voorwaarden voor Set Fault Code Active

  • IMF 3 wordt ingesteld wanneer een kort 12 volt wordt gedetecteerd aan de bedieningszijde van hoogspanningslijnen.
  • IMF 4 wordt ingesteld wanneer een kort naar massa wordt gedetecteerd aan de bedieningszijde van hoogspanningslijnen.
  • IMF 5 en FMI 10 worden ingesteld wanneer een onderbreking wordt gedetecteerd aan de bedieningszijde van hoogspanningslijnen.
  • IMF 7 en FMI 14 worden ingesteld als de belangrijkste negatieve relais ingeschakeld en de omvormer condensator spanningsdaling kleiner is dan 10 volt / 5 seconden wanneer initiële condensatorspanning groter dan 200 volt.

Terugval Als Fault Code 116 ingesteld gebeurt het volgende:

  • Amber “Controle Hybrid” gaat branden.
  • Storing wordt opgeslagen in Hybrid Control Module (HCM) geheugen.
  • Het hybride systeem zal offline zijn.
  • Transmission defaults start gear to 1st in diesel-only mode.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Voorwaarden voor Set Fault Code Inactieve

Alleen niet-actieve fouten kunnen worden gewist uit het TECU of HCM geschiedenis met behulp ServiceRanger. De TECU verdwijnt automatisch de fouten uit de geschiedenis na 200 uur. De HCM wist een fout uit de geschiedenis automatisch na die fout inactief is geweest 200 uur.

Deze fout code kan worden veroorzaakt door een van de volgende:

  • IMF 3, 4, 5, 7, 10, 14
    • Voltage feedback draad van DC / DC Converter om HCM
  • IMF 4
    • relaiskast
    • Inertia Switch
    • inverter
    • Kabelboom van het voertuig tussen de omvormer en de PEC
    • Main High-Voltage service zekering is doorgebrand of ontbreekt
    • DC High-Voltage Cable Interlock
    • PEC Red Button Dienst Switch

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fout code 116 – High Voltage Relais Fault Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Identificatie van de onderdelen:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14476|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40-contrasteker view omvormer laagspanningsconnector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Duetsch 40-contrasteker view
(Omvormer laagspanningsconnector)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Contrasteker view Deutsch 19-way ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Contrasteker view
(Deutsch 19-polige stekker)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTITIE: Verwijs naar de Eaton Hybrid Component en aansluiting Plaats voor Connector Locaties in MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14672|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Omvormer PEC MY09 Systems” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”waarschuwingen & waarschuwingen” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Gevaar: Gevaar betekent zult u ernstig gewond raken of gedood als niet de aangegeven procedure niet volgen.
Waarschuwing: Waarschuwing duidt op een onmiddellijk gevaar, die kan leiden tot ernstig persoonlijk letsel als je niet de aangegeven procedure te volgen.
Voorzichtigheid: Let op geeft voertuig of materiële schade zou kunnen ontstaan ​​als je niet de aangegeven procedure te volgen.

Notitie: Note geeft bijkomende details die helpen bij de diagnose of reparatie van een onderdeel / systeem.

Volg de voorgeschreven procedures in de aangegeven volgorde om persoonlijk letsel te voorkomen:

1. Als het hoogspanningsnet kegels zijn rond het voertuig en de lock-out is geïnstalleerd op de PEC, de enige persoon die moet worden toegestaan ​​om het voertuig te starten is de persoon die de lockout tag ondertekend.
2. Voor werkzaamheden aan een voertuig of de cabine te verlaten, terwijl de motor loopt, moet u de versnellingspook in “N” plaatsen trek de handrem, en blokkeren de wielen.
3. Voor veiligheidsredenen, altijd de bedrijfsremmen aangrijpen vóór selectie schakelstanden van “N.”
4. Voordat u begint met een voertuig altijd zitten in de bestuurdersstoel, Selecteer “N” op de schakelbesturingsinrichting, en stel de handrem.
5. In voertuigen met EPTO, de motor en / of
Motor / Generator kan starten in EPTO modus. Voer nooit onderhoud of werken aan het voertuig, In deze modus.
6. 12-Volt batterij positief (+) en negatieve (-) moet vooraf worden losgekoppeld laswerkzaamheden op een hybride voertuig uitgerust.

Voorzichtigheid: Volg de voorgeschreven procedures in de aangegeven volgorde om apparatuur storingen of schade te voorkomen.
Voorzichtigheid: Laat de parkeerrem niet vrijgeven of een poging om een ​​versnelling te selecteren totdat de luchtdruk op het juiste niveau.
Voorzichtigheid: Om beschadiging van de transmissie tijdens het slepen plaats de schakelhefboom in “N” te vermijden en til de aandrijfwielen van de grond en koppel de aandrijflijn.

High-Voltage Waarschuwingen & waarschuwingen

  • Gebruik CO2 of Dry Chemical Brandblussers.
  • De hoogspanning bedrading bedekt met oranje isolatie of gekronkelde slangen en aangegeven met waarschuwingen op de connectoren.
  • Alle Eaton® Hybride Diesel / Elektrische voertuigen zullen worden gemarkeerd als ‘Hybrid’ aan de buitenzijde van het voertuig, samen met de verschuiving label op het dashboard.
  • Raadpleeg OEM voor specifieke locatie van het chassis gemonteerde hybridecomponenten.
  • Knip niet in de oranje hoogspanningskabels.
  • Niet snijden in of open de PEC.
  • Knip niet in of de DC / DC-converter te openen.
  • Niet snijden in of open de Inverter.

Een bufferzone moet worden opgezet en hoogspanningsinstallaties geïsoleerde rubberhandschoenen (klasse 0 met lederen beschermers) zijn voorafgaand moeten aan hoogspanning. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
De rubber isolerende handschoenen die moeten worden gedragen tijdens het werken op de high-voltage systeem zijn klasse 0 met lederen beschermers. De rubberen handschoenen moeten worden getest voor elk gebruik na de rubberen isolatie handschoenen testprocedure vinden in “Diagnostic Tools / Dienst Publicaties” op pagina 6. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Voordat het inspecteren of werken op elk hoogspanningskabels of onderdelen van het “High-Voltage service Shutdown en Power-Up procedure” op pagina 4 moet worden gevolgd. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
De Lockout en Tagout apparaten mag alleen worden verwijderd door de technicus die de Lockout en Tagout op het voertuig geplaatst. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Hoogspanning rubber isolerende handschoenen (klasse 0 met lederen beschermers) moet gedragen worden bij het werken op een
hoogspanningskabels. De “High-Voltage service Shutdown en Power-Up procedure” op pagina 4 moet voor worden gevolgd om het verwijderen van hoogspanningskabels. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Hoogspanningskabels en bedrading zijn oranje en voorzien van een waarschuwingslabel op de connectoren. Hoogspanningsonderdelen worden gemarkeerd met een label. Hoogspanning rubber isolerende handschoenen (klasse 0 met lederen beschermers) moeten worden bij het werken op een van deze componenten. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.

High-Voltage Dienst Uitschakelprocedures

High-Voltage service Shutdown en Power-Up Procedure1. Volg de “High-Voltage Work Area” -procedure.
2. Zoek de rode PEC Dienst Switch aan de voorzijde van de PEC en druk uit te schakelen.
3. Verwijder de Dienst Switch Cover en installeer de Lockout Bracket (J48506).
4. Bevestig tag aan de Lockout Bracket.
5. Zorg ervoor dat de PEC Dienst Switch kan niet verplaatsen van de uit-stand.
6. Laat het systeem in te stellen voor een minimum van 5 minuten hoogspanningsontlading.
7. Sluit ServiceRanger en bekijk de Data Monitor PID 116 genaamd “High-Voltage Potential Battery.” Gebruik SPN 520323 voor J1939 aansluiting “Battery Voltage RB” (relaiskast).
8. De spanning moet 30 volt of minder. Indien de spanning boven 30 volt, werken niet op het voertuig en neem contact op Eaton® bij 1-800-826-HELP (4357).
9. Draai de contactsleutel uit en ga verder met repareren of stap het oplossen van problemen.
Notitie: De spanning daalt tot nul wanneer de sleutel uit.

High-Voltage dienst Power-Up Procedure

1. Installeer alle high-voltage connectoren in hun vergrendelde positie.
2. Als je de persoon die werkzaamheden aan het voertuig, verwijder de Lockout Bracket en tag.
3. Installeer de Lockout beugel over de Dienst Switch.
4. Trek de Dienst Schakel uit en laat het voertuig set voor 2 notulen.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Component en aansluiting Plaats ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Component en locaties van de aansluiting MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Component en aansluiting Plaats MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Component en locaties van de aansluiting MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 1.Verify onderhavige FMIS.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Herzien en volg de waarschuwingen & waarschuwingen.
  2. Ophalen Actieve foutcodes en FMIS met ServiceRanger met behulp van de 9-polige diagnose-aansluiting.
  3. Met behulp van ServiceRanger, opnemen lezingen in “Data Monitor” onder J1939 gegevens HV Battery: Parameter 520250 HV batterij1 potentiële spanning en parameter 520323 Battery Voltage RB. Kijk spanning op Accuspanning RB tijdens de toets op en opnemen spanning stappen indien die aanwezig zijn.
  4. Welke FMIS aanwezig zijn?
    • Als Fault Code 116 IMF 3 is genoteerd, ga dan naar stap 2.
    • Als Fault Code 116 IMF 4 is genoteerd, ga dan naar stap 4.
    • Als Fault Code 116 IMF 5 of 10 is genoteerd, ga dan naar stap 6.
    • Als Fault Code 116 IMF 7 is genoteerd, ga dan naar stap 13.

[/fusion_content_box][fusion_content_box title=STAP 2. Controleer of reparatie.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off, Wacht 1 minuut.
  2. Koppel de 40-Way Inverter Connector.
  3. sleutel op (dit zal een foutcode te stellen 88, duidelijke fout na het repareren).
  4. Op Vehicle Harness, controleren op eventuele spanning op de pinnen 21, 31, 22, 32, 23 en 33 aan de grond:
    • Indien spanning wordt gevonden, Verwijder 19-polige stekker van de PEC en controleer opnieuw voor spanning bij Inverter 40-Pin, ga dan naar stap 3.
    • Indien aangesloten blijft, reparatie van voertuigen tussen omvormer en de 40-Pin, ga dan naar stap 3.
    • Als de spanning weg, ga dan naar stap 3

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 3. Controleer de continuïteit van de PEC Connector circuits aan de grond.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. 1. Key off.
    2. Koppel de PEC 19-polige stekker (rode Dienst Switch moet nog steeds worden uitgetrokken).
    3. Meet de weerstand op de volgende 19-Way Connector terminals:

    • Pin 9 vastpinnen 6 en Pin 9 vastpinnen 12
    • Pin 13 vastpinnen 6 en Pin 13 vastpinnen 12
    • Pin 17 vastpinnen 6 en Pin 17 vastpinnen 12
      • Als open circuit, ga dan naar stap 2.
      • Als er weerstand wordt gevonden, vervang de Relay Box, ga dan naar stap 14.

[/fusion_content_box][fusion_content_box title=STAP 4. Controleer de continuïteit van de Inverter Connector circuits.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Koppel de omvormer 40-polige stekker (19-Way Connector bij PEC moet worden aangesloten met rode Dienst Switch uitgetrokken).
  3. Op Vehicle Harness, controleren op weerstand op de massa op pin 21 aan de grond, Pin 22 aan de grond en Pin 23 aan de grond:
    • Als enige weerstand van de frequentieregelaar aansluitingen naar aarde wordt gevonden, verbreken PEC 19-polige stekker en controleer de OEM 40-polige stekker.
    • Als de weerstand is nog steeds gevonden met de 19-Way losgekoppeld, het herstel van de Vehicle Harness, ga dan naar stap 14.
    • Als weerstand wordt gegaan met de 19-Way losgekoppeld, ga dan naar stap 5.
    • Als tellerstanden OL of Open Circuit, vervang de Inverter, ga dan naar stap 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 5. Controleer de continuïteit van de PEC Connector circuits aan de grond.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Koppel de PEC 19-polige stekker.
  3. Op de PEC 19-polige stekker, maatregel:
    • Pin 9, Pin 13 en Pin 17 aan de grond
    • Pin 9 vastpinnen 7, Pin 9 vastpinnen 10, Pin 9 naar PEC montagetapeind
    • Pin 13 vastpinnen 7, Pin 13 vastpinnen 14, Pin 13 naar PEC montagetapeind
    • Pin 17 vastpinnen 7, Pin 17 vastpinnen 14, Pin 17 naar PEC montagetapeind
      • Wanneer één weerstand gevonden van de PEC Pins met aarde, vervang de Relay Box. Zie de MY09 PEC High-Voltage Relay Box verwijderen en installeren procedure in TRSM2000, ga dan naar stap 14.
      • Als tellerstanden OL, hertesten nodig, ga dan naar stap 4.

[/fusion_content_box][fusion_content_box title=STAP 6. Controleer de continuïteit van de PEC Connector circuits.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Koppel de PEC 19-polige stekker. (Rode Dienst Button op PEC moet worden uitgetrokken.)(Do “Hybride Stopzetprocedure” nog niet uit te voeren.)
  3. Meet de weerstand op de PEC Connector:
    • Pin 9 vastpinnen 11
    • Pin 13 vastpinnen 15
    • Pin 17 vastpinnen 19
      • Als de weerstand tussen Pin 9 en Pin 11, en Pin 13 vastpinnen 15 zijn elk 33-37 ohm en de weerstand van Pin 17 vastpinnen 19 is 112-122 ohm, ga dan naar stap 7.
      • Wanneer één weerstand buiten bereik, reset de Inertia Switch zich in luchtfilter opening of in achterklep van de High-Voltage Fuse, ga dan naar stap 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 7. Controleer de hoogspanningskabel interlock op de OEM Cable.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Controleer of de Inertia Switch is OK.
  2. Meet de weerstand van de interlock Pins aan de OEM Cable.
    Gevaar: Zien High-Voltage service Shutdown en Power-Up Procedures. Volg de procedures om schokken te voorkomen, branden of overlijden als gevolg van onjuist gebruik high-voltage.

    • Als de weerstand 0-0,3 ohm, vervang de Relay Box, ga dan naar stap 9.
    • Als de weerstand OL, vervang de High-Voltage DC-kabel, ga dan naar stap 8.

[/fusion_content_box][fusion_content_box title=STAP 8. Controleer de continuïteit van de PEC Connector circuits aan de grond.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Meet de weerstand op de PEC Connector (rode Dienst Button Switch wordt uitgetrokken):
    • Pin 9 vastpinnen 11
    • Pin 17 vastpinnen 19
      • Als er weerstand is OL, vervang de Relay Box (inspecteer de bedrading in te gaan op relaiskast vóór het vervangen), ga dan naar stap 9.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 9. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Als het voertuig is uitgerust met Export Vermogen PEC, het uitvoeren van “High-Voltage service Shutdown en Power-Up procedure” op pagina 4, verwijder vervolgens High-Voltage DC / DC en / of APG High-Voltage Cable van de PEC. Installeer Interlock Caps indien beschikbaar:
    • Als het voertuig niet is uitgerust met Export Vermogen, ga dan naar stap 11.

[/fusion_content_box][fusion_content_box title=STAP 10. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Na DC / DC en APG hoogspanningskabels verwijderd, pull out red Service Switch and connect 19- Way Connector op de PEC.
  2. sleutel op:
    • Als Fault Code 116 / FMI 5 is nog steeds actief, ga dan naar stap 12.
    • Als Fault Code 116 / FMI 5 is weg, ga dan naar stap 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 11. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Plug DC / DC en / of APG kabels terug in PEC en controleer of Fault Code 116 / FMI 5 is nog steeds actief:
    • Als er nog steeds actief, ga dan naar stap 12.
    • Als inactieve, hulprelais in de PEC gelast. Vervang de PEC. Zie de MY09 Elektrisch Carrier (PEC) Uitbouwen en inbouwen, Alternatieve Elektrisch Carrier (PEC) Removal and Installation or 4- Battery Power Electric Carrier (PEC) verwijderingsprocedures en installatie in TRSM2000.
      Ook, inspect the Auxiliary Relay Circuit for loose Interlock Connections causing relay chatter under load see Fout code 118 – Extra High Voltage Relay Controle Circuit Fault voor schakelingsbeschrijving).
    • Nadat de reparaties zijn voltooid, ga dan naar stap 14.

[/fusion_content_box][fusion_content_box title=STAP 12. Controleer de continuïteit van de Inverter Connector circuits. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Sluit de PEC 19-polige stekker.
  2. Koppel de omvormer 40-polige stekker.
  3. Meet de weerstand bij de Inverter 40-Way OEM Connector Terminal op de volgende pinnen:
    • Pin 21 vastpinnen 31
    • Pin 22 vastpinnen 32
    • Pin 23 vastpinnen 33
      • Als de weerstand tussen Pin 21 en Pin 31 is 112-122 ohm en de weerstand van Pin 22 vastpinnen 32, en Pin 23 vastpinnen 33 elk 33-37 ohm, vervang de Inverter (zie MY09 Inverter uitbouwen en inbouwen), ga dan naar stap 14.
      • Als de weerstand buiten bereik, het herstel van de Vehicle Harness tussen de omvormer en de PEC, ga dan naar stap 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 13. Meet de accuspanning.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Sluit ServiceRanger naar de 9-Way diagnose-aansluiting in de cabine.
  2. Selecteer de optie “Data Monitor”.
  3. Bekijk de volgende parameters in de high-voltage accu lijst:
    • HV Battery J1939 gegevens HV Battery:
      Parameter 520250 HV batterij1 Potentiële Spanning en Parameter 520323 Battery Voltage RB
    • Druk de rode knop Service.
    • Als de spanning lezingen op batterij1 Potentiële Voltage en Battery Voltage RB zijn binnen 10 volts elkaar (Battery Voltage RB moet dalen tot 30 volt wanneer de rode Dienst Switch in werd geduwd), vervang de Relay Box. Zie de MY09 PEC High-Voltage Relay Box verwijderen en installeren procedure in TRSM2000, ga dan naar stap 14.
      Notitie: “High-Voltage Dienst Afsluiten en
      Zien High-Voltage service Shutdown en Power-Up Procedures moet worden vooraleer men hoogspanningskabel. (Als belangrijkste
      High-Voltage Relais zijn gelast, verwijderen high-voltage zekering in achterklep voordat eventuele reparaties).
    • Als de spanning lezingen op batterij1 Potentiële Voltage en Battery Voltage RB groter zijn dan 10 volts elkaar (Battery Voltage RB moet dalen tot 30 volt wanneer de rode Dienst Switch in werd geduwd), vervang de Inverter, ga dan naar stap 14.

[/fusion_content_box][fusion_content_box title=STAP 14. Controleer of reparatie.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Sluit alle connectors en de negatieve accukabel.
  3. sleutel op.
  4. Clear codes, zien Clear Inactieve Storingen.
  5. Het voertuig rijdt en probeer de code opnieuw in te stellen.
  6. Controleer op codes, zien Toon actieve en inactieve Storingen.
    • Als er geen codes, test is voltooid.
    • Als fout Code 116 komt naar voren, vind fout bij het testen, ga dan naar stap 1.
    • Als een code anders dan 116 komt naar voren, zien Storing Code Index List.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]