[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Transmisi Patahan Kode 116 – Tegangan Tinggi Relay Patahan – (sistem MY09)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kesalahan kode untuk Eaton Hybrid Drive Sistem model (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P dan EH-6E706B-UPG. Baca di bawah untuk belajar bagaimana untuk menguji, membersihkan dan memperbaiki kesalahan kode kesalahan untuk Freightliner Anda, mack, Peterbilt, Kenworth, volvo, Internasional, dan tugas berat truk dan peralatan. The Relay Tegangan Tinggi terletak di dalam Power
Electronics pembawa (PEC) di unit Relay Box. There is one Pre-Charge Relay on the positive side, relay tambahan pada hal positif, and on the negative for a total of three relays. relay ini biasanya terbuka ketika sistem dimatikan. Relay dikendalikan melalui Inverter.
kesalahan Kode 116 – Tegangan Tinggi Relay kesalahan Deteksi
Prasyarat berikut harus dipenuhi sebelum sistem mendeteksi kesalahan:
- tegangan inverter pengapian lebih besar dari 7 volt dan kurang dari 16 volt.
Catatan: Ketika masalah kode aktif mengacu pada Produk Diagnostik Mode (PDM)
Kondisi Set Patahan Kode Aktif
- IMF 3 diatur ketika pendek untuk 12 volt terdeteksi di sisi kontrol relay tegangan tinggi.
- IMF 4 diatur ketika pendek ke tanah terdeteksi di sisi kontrol relay tegangan tinggi.
- IMF 5 dan FMI 10 ditetapkan ketika rangkaian terbuka terdeteksi di sisi kontrol relay tegangan tinggi.
- IMF 7 dan FMI 14 ditetapkan ketika relay negatif utama adalah pada dan inverter penurunan tegangan kapasitor adalah kurang dari 10-volt / 5 detik ketika tegangan kapasitor awal adalah lebih besar dari 200 volt.
Fallback Ketika Patahan Kode 116 diatur kondisi berikut terjadi:
- Amber “Periksa Hybrid” menyala terang.
- Kesalahan disimpan di Control Hybrid Modul (HCM) ingatan.
- Sistem hybrid akan offline.
- Transmission defaults start gear to 1st in diesel-only mode.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kondisi Set Patahan Kode Aktif
Hanya kesalahan yang tidak aktif bisa dibersihkan dari TECU atau HCM sejarah menggunakan ServiceRanger. The TECU otomatis membersihkan kesalahan dari sejarah setelah 200 jam. HCM otomatis membersihkan kesalahan dari sejarah setelah kesalahan yang telah tidak aktif 200 jam.
Kode kesalahan ini dapat disebabkan oleh salah satu dari berikut:
- IMF 3, 4, 5, 7, 10, 14
- Tegangan Umpan balik kawat dari DC / DC Converter untuk HCM
- IMF 4
- Relay Box
- inersia Beralih
- inverter
- Kendaraan Wiring Harness antara Inverter dan PEC
- Main Tegangan Tinggi Jasa Fuse ditiup atau hilang
- DC Tegangan Tinggi Kabel interlock
- PEC Red Tombol Service Switch
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
kesalahan Kode 116 – Tegangan Tinggi Relay Patahan Uji
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identifikasi komponen:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14476|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40-way konektor kawin pandangan Inverter konektor tegangan rendah” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Duetsch 40-cara tampilan konektor kawin
(Inverter konektor tegangan rendah)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14213|medium” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Kawin tampilan konektor Deutsch 19-way ” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kawin tampilan konektor
(Deutsch konektor 19-way)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
CATATAN: Mengacu kepada Eaton Hybrid Komponen dan Connector Lokasi untuk Connector Lokasi di MY09 Sistem.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14672|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Inverter untuk PEC MY09 Sistem” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”peringatan & Perhatian” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Bahaya: Bahaya menunjukkan Anda akan terluka parah atau terbunuh jika tidak mengikuti prosedur yang ditunjukkan.
Peringatan: Peringatan menunjukkan bahaya langsung, yang dapat mengakibatkan cedera pribadi yang parah jika Anda tidak mengikuti prosedur yang ditunjukkan.
Peringatan: Perhatian menunjukkan kendaraan atau kerusakan properti bisa terjadi jika Anda tidak mengikuti prosedur yang ditunjukkan.
Catatan: Catatan menunjukkan rincian tambahan yang akan membantu dalam diagnosis atau perbaikan komponen / sistem.
Ikuti prosedur yang ditetapkan dalam urutan yang ditunjukkan untuk menghindari cedera:
1. Jika kerucut tegangan tinggi sekitar kendaraan dan lockout dipasang di PEC, satu-satunya orang yang harus diperbolehkan untuk memulai kendaraan adalah orang yang menandatangani tag lockout.
2. Sebelum bekerja pada kendaraan atau meninggalkan taksi sementara mesin sedang berjalan, Anda harus menempatkan tuas pergeseran “N” set rem parkir, dan memblokir roda.
3. Untuk alasan keselamatan, selalu terlibat rem layanan sebelum memilih posisi gigi dari “N.”
4. Sebelum memulai kendaraan selalu duduk di kursi pengemudi, pilih “N” pada kontrol pergeseran, dan mengatur rem tangan.
5. Dalam kendaraan dengan ePTO, mesin dan / atau
Motor / Generator dapat mulai di modus ePTO. Tidak pernah melakukan perawatan atau bekerja pada kendaraan, Dalam modus ini.
6. 12-Volt Baterai positif (+) dan negatif (-) harus diputuskan sebelum pengelasan pada setiap Hybrid dilengkapi kendaraan.
Peringatan: Ikuti prosedur yang ditetapkan dalam urutan yang ditunjukkan untuk menghindari kerusakan peralatan atau kerusakan.
Peringatan: Jangan melepaskan rem parkir atau mencoba untuk memilih gigi sampai tekanan udara pada tingkat yang benar.
Peringatan: Untuk menghindari kerusakan transmisi selama penarik tempat tuas shift di “N” dan mengangkat roda penggerak dari tanah atau memutuskan driveline.
Peringatan Tegangan Tinggi & Perhatian
- Gunakan CO2 atau Dry Chemical Fire Extinguishers.
- Tegangan tinggi kabel ditutupi isolasi oranye atau tubing berbelit-belit dan ditandai dengan label peringatan pada konektor.
- Semua Eaton® Hybrid Diesel / kendaraan listrik akan ditandai ‘Hybrid’ di luar kendaraan, bersama dengan label pergeseran di dasbor.
- Mengacu pada OEM untuk lokasi tertentu dari chassis mount komponen hybrid.
- JANGAN potong kabel tegangan tinggi orange.
- TIDAK potong atau membuka PEC.
- TIDAK potong atau membuka Converter DC / DC.
- TIDAK potong atau membuka Inverter.
Sebuah zona penyangga harus diatur dan tegangan tinggi terisolasi sarung tangan karet (kelas 0 dengan pelindung kulit) diperlukan sebelum bekerja di tegangan tinggi. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Sarung tangan karet-terisolasi yang harus dikenakan saat bekerja pada sistem tegangan tinggi adalah kelas 0 dengan pelindung kulit. Sarung tangan karet harus diuji sebelum SETIAP digunakan mengikuti prosedur sarung tangan karet isolasi pengujian ditemukan di “Diagnostik Alat / Jasa Publikasi” pada halaman 6. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Sebelum memeriksa atau bekerja pada setiap kabel tegangan tinggi atau komponen yang “Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur” pada halaman 4 harus diikuti. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
The Lockout dan tagout perangkat hanya harus dihapus oleh teknisi yang menempatkan perangkat Lockout dan tagout pada kendaraan. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Tegangan tinggi karet terisolasi sarung tangan (kelas 0 dengan pelindung kulit) harus dipakai saat bekerja pada setiap
kabel tegangan tinggi. The “High-Voltage Layanan Shutdown dan Power-Up Prosedur” pada halaman 4 harus diikuti sebelum menghapus setiap kabel tegangan tinggi. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Tegangan tinggi kabel dan kabel yang oranye dan mengandung label peringatan pada konektor. komponen tegangan tinggi ditandai dengan label. Tegangan tinggi karet terisolasi sarung tangan (kelas 0 dengan pelindung kulit) harus digunakan ketika bekerja pada salah satu komponen ini. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Prosedur Layanan Shutdown Tegangan Tinggi
1. Ikuti “Tegangan Tinggi Wilayah Kerja” Prosedur.
2. Menemukan merah PEC Service Switch di depan PEC dan mendorong mematikan.
3. Lepaskan Service Switch Tutup dan menginstal Bracket Lockout (J48506).
4. tag Kencangkan ke Lockout Bracket.
5. Pastikan PEC Service Switch tidak bisa bergerak dari posisi off.
6. Memungkinkan sistem untuk mengatur selama minimal 5 menit untuk melepaskan tegangan tinggi.
7. Hubungkan ServiceRanger dan melihat Data Monitor PID 116 disebut “Tegangan Tinggi Potensi Battery.” Gunakan SPN 520323 untuk koneksi J1939 “Battery Voltage RB” (Relay Box).
8. tegangan harus 30 volt atau kurang. Jika tegangan di atas 30 volt, tidak bekerja pada kendaraan dan menghubungi Eaton® di 1-800-826-HELP (4357).
9. Putar kunci kontak off dan melanjutkan untuk memperbaiki atau langkah pemecahan masalah.
Catatan: tegangan turun ke nol ketika kuncinya adalah off.
Tegangan Tinggi Jasa Power-Up Prosedur
1. Install semua konektor tegangan tinggi ke posisi mereka terkunci.
2. Jika Anda adalah orang yang bekerja pada kendaraan, menghapus Lockout Bracket dan tag.
3. Instal ulang Lockout Bracket atas Service Switch.
4. Tarik Jasa Beralih keluar dan membiarkan kendaraan ditetapkan untuk 2 menit.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Komponen dan Connector Lokasi ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Komponen dan Connector Lokasi MY09 Sistem” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 1.Verify FMIS hadir.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Tinjau dan ikuti peringatan & Perhatian.
- Ambil kode kesalahan aktif dan FMIS dengan ServiceRanger menggunakan 9-Way Diagnostik Connector.
- menggunakan ServiceRanger, rekor pembacaan di “Data Monitor” di bawah Baterai J1939 data HV: Parameter 520250 HV Battery1 potensial tegangan dan parameter 520323 Baterai Tegangan RB. Perhatikan tegangan pada baterai Tegangan RB selama kunci dan langkah-langkah tegangan catatan jika ada yang hadir.
- Yang FMIS hadir?
- Jika Kode Kesalahan 116 IMF 3 terdaftar, pergi ke Langkah 2.
- Jika Kode Kesalahan 116 IMF 4 terdaftar, pergi ke Langkah 4.
- Jika Kode Kesalahan 116 IMF 5 atau 10 terdaftar, pergi ke Langkah 6.
- Jika Kode Kesalahan 116 IMF 7 terdaftar, pergi ke Langkah 13.
[/fusion_content_box][fusion_content_box title=”LANGKAH 2. Verifikasi perbaikan.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci, Tunggu 1 menit.
- Lepaskan 40-Way Inverter Connector.
- tombol pada (ini akan menetapkan Kode Kesalahan 88, kesalahan jelas setelah perbaikan).
- Pada Kendaraan Harness, memeriksa setiap tegangan pada pin 21, 31, 22, 32, 23 dan 33 ke tanah:
- Jika tegangan apapun yang ditemukan, menghapus 19-Way Connector pada PEC dan recheck untuk tegangan pada Inverter 40-Pin, kemudian pergi ke Langkah 3.
- Jika tegangan masih ada, perbaikan kendaraan antara Inverter dan 40-Pin, kemudian pergi ke Langkah 3.
- Jika tegangan hilang, pergi ke Langkah 3
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 3. Verifikasi kelangsungan sirkuit Connector PEC ke tanah.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- 1. off kunci.
2. Lepaskan PEC 19-Way Connector (Layanan merah Beralih tetap harus ditarik keluar).
3. Mengukur resistansi pada terminal 19-Way Connector berikut:- Pin 9 Pin 6 dan Pin 9 Pin 12
- Pin 13 Pin 6 dan Pin 13 Pin 12
- Pin 17 Pin 6 dan Pin 17 Pin 12
- Jika sirkuit terbuka, pergi ke Langkah 2.
- Jika perlawanan ditemukan, menggantikan Relay Box, kemudian pergi ke Langkah 14.
[/fusion_content_box][fusion_content_box title=”LANGKAH 4. Verifikasi kelangsungan sirkuit Inverter Connector.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Lepaskan Inverter 40-Way Connector (19-Cara Connector di PEC harus dihubungkan dengan Layanan merah Beralih ditarik keluar).
- Pada Kendaraan Harness, memeriksa perlawanan terhadap tanah di Pin 21 ke tanah, Pin 22 ke tanah dan Pin 23 ke tanah:
- Jika ada perlawanan dari Konektor Inverter ke tanah ditemukan, lepaskan PEC 19-Way Connector dan recheck OEM 40-Way Connector.
- Jika resistance masih ditemukan dengan 19-Way terputus, memperbaiki Kendaraan Harness, kemudian pergi ke Langkah 14.
- Jika resistance hilang dengan 19-Way terputus, pergi ke Langkah 5.
- Jika meter membaca OL atau Open Circuit, mengganti Inverter, kemudian pergi ke Langkah 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 5. Verifikasi kelangsungan sirkuit Connector PEC ke tanah.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Lepaskan PEC 19-Way Connector.
- Di PEC 19-Way Connector, mengukur:
- Pin 9, Pin 13 dan Pin 17 ke tanah
- Pin 9 Pin 7, Pin 9 Pin 10, Pin 9 untuk PEC Mounting Stud
- Pin 13 Pin 7, Pin 13 Pin 14, Pin 13 untuk PEC Mounting Stud
- Pin 17 Pin 7, Pin 17 Pin 14, Pin 17 untuk PEC Mounting Stud
- Jika perlawanan ditemukan dari Pins PEC ke tanah, menggantikan Relay Box. Lihat MY09 PEC Tegangan Tinggi Relay Box Removal dan prosedur Instalasi di TRSM2000, kemudian pergi ke Langkah 14.
- Jika meter membaca OL, pengujian ulang diperlukan, pergi ke Langkah 4.
[/fusion_content_box][fusion_content_box title=”LANGKAH 6. Verifikasi kelangsungan sirkuit Connector PEC.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Lepaskan PEC 19-Way Connector. (Red Jasa Tombol pada PEC harus ditarik keluar.)(Jangan melakukan “Hybrid Prosedur Shutdown” belum.)
- Mengukur resistensi pada PEC Connector:
- Pin 9 Pin 11
- Pin 13 Pin 15
- Pin 17 Pin 19
- Jika perlawanan antara Pin 9 dan Pin 11, dan Pin 13 Pin 15 masing-masing 33-37 ohm dan perlawanan dari Pin 17 Pin 19 adalah 112-122 ohm, pergi ke Langkah 7.
- Jika perlawanan berada di luar jangkauan, reset Beralih Inertia terletak di dalam pembukaan filter udara atau di Belakang Access Panel oleh Tegangan Tinggi Fuse, kemudian pergi ke Langkah 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 7. Periksa kabel tegangan tinggi interlock pada kabel OEM.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Verifikasi bahwa Inertia Switch OK.
- Mengukur resistensi dari Pins interlock pada kabel OEM.
Bahaya: Lihat Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur. Ikuti prosedur untuk menghindari kejutan, membakar atau kematian dari tidak benar ditangani tegangan tinggi.- Jika resistance adalah 0-0,3 ohm, menggantikan Relay Box, kemudian pergi ke Langkah 9.
- Jika resistance ini OL, menggantikan kabel Tegangan Tinggi DC, kemudian pergi ke Langkah 8.
[/fusion_content_box][fusion_content_box title=”LANGKAH 8. Verifikasi kelangsungan sirkuit Connector PEC ke tanah.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Mengukur resistensi pada PEC Connector (merah Jasa Tombol Switch ditarik keluar):
- Pin 9 Pin 11
- Pin 17 Pin 19
- Jika perlawanan adalah OL, menggantikan Relay Box (Periksa kabel pergi ke Relay Box sebelum mengganti), kemudian pergi ke Langkah 9.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 9. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Jika kendaraan dilengkapi dengan Ekspor Listrik PEC, melakukan “Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur” pada halaman 4, kemudian menghapus Tegangan Tinggi DC / DC dan / atau APG Tegangan Tinggi Kabel dari PEC. Instal interlock Caps jika tersedia:
- Jika kendaraan tidak dilengkapi dengan Ekspor Listrik, pergi ke Langkah 11.
[/fusion_content_box][fusion_content_box title=”LANGKAH 10. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Setelah DC / DC dan APG kabel tegangan tinggi dihapus, pull out red Service Switch and connect 19- Cara Connector di PEC.
- tombol pada:
- Jika kesalahan Kode 116 / FMI 5 masih aktif, pergi ke Langkah 12.
- Jika kesalahan Kode 116 / FMI 5 hilang, pergi ke Langkah 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 11. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Plug DC / DC dan / atau kabel APG kembali ke PEC dan memverifikasi bahwa Sesar Kode 116 / FMI 5 masih aktif:
- Jika masih aktif, pergi ke Langkah 12.
- Jika tidak aktif, Relay Auxiliary dalam PEC yang dilas. Menggantikan PEC. Lihat Carrier MY09 Tenaga Listrik (PEC) Penghapusan dan Instalasi, Alternatif Pembawa Tenaga Listrik (PEC) Removal and Installation or 4- Baterai Tenaga Listrik Pembawa (PEC) Penghapusan dan Instalasi prosedur di TRSM2000.
Juga, inspect the Auxiliary Relay Circuit for loose Interlock Connections causing relay chatter under load see kesalahan Kode 118 – Auxiliary High Voltage Relay Kontrol Circuit Patahan untuk deskripsi sirkuit). - Setelah perbaikan selesai, pergi ke Langkah 14.
[/fusion_content_box][fusion_content_box title=”LANGKAH 12. Verifikasi kelangsungan sirkuit Inverter Connector. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Hubungkan PEC 19-Way Connector.
- Lepaskan Inverter 40-Way Connector.
- Mengukur resistensi di Inverter 40-Way OEM Connector Terminal di pin berikut:
- Pin 21 Pin 31
- Pin 22 Pin 32
- Pin 23 Pin 33
- Jika perlawanan antara Pin 21 dan Pin 31 adalah 112-122 ohm dan perlawanan dari Pin 22 Pin 32, dan Pin 23 Pin 33 masing-masing 33-37 ohm, mengganti Inverter (melihat MY09 Inverter Penghapusan dan Instalasi), kemudian pergi ke Langkah 14.
- Jika resistance di luar jangkauan, memperbaiki Kendaraan Harness antara Inverter dan PEC, kemudian pergi ke Langkah 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 13. tegangan baterai ukuran.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Hubungkan ServiceRanger ke 9-Way Diagnostik Konektor di dalam taksi.
- Pilih “Data Monitor” pilihan.
- Lihat parameter berikut dalam daftar baterai tegangan tinggi:
- Baterai HV Baterai J1939 data HV:
Parameter 520250 HV Battery1 Potensi Voltage dan Parameter 520323 Baterai Tegangan RB - Dorong di Tombol Jasa merah.
- Jika pembacaan tegangan pada Battery1 Tegangan Potensi dan Baterai Tegangan RB berada dalam 10 volt satu sama lain (Baterai Tegangan RB harus drop ke 30 volt ketika Service Switch merah didorong di), menggantikan Relay Box. Lihat MY09 PEC Tegangan Tinggi Relay Box Removal dan prosedur Instalasi di TRSM2000, kemudian pergi ke Langkah 14.
Catatan: “Tegangan Tinggi Jasa Shutdown dan
Lihat Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur harus dilakukan sebelum melepas kabel tegangan tinggi. (Jika utama
Relay Tegangan Tinggi dilas, menghapus tegangan tinggi sekering terletak di Belakang Access Panel sebelum mencoba perbaikan apapun). - Jika pembacaan tegangan pada Battery1 Tegangan Potensi dan Baterai Tegangan RB lebih besar dari 10 volt satu sama lain (Baterai Tegangan RB harus drop ke 30 volt ketika Service Switch merah didorong di), mengganti Inverter, kemudian pergi ke Langkah 14.
- Baterai HV Baterai J1939 data HV:
[/fusion_content_box][fusion_content_box title=”LANGKAH 14. Verifikasi perbaikan.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Sambungkan kembali semua konektor dan kabel baterai negatif.
- tombol pada.
- kode jelas, Lihat Kesalahan aktif jelas.
- Menggerakkan kendaraan dan berusaha untuk me-reset kode.
- Periksa kode, Lihat Lihat Kesalahan Aktif dan Tidak Aktif.
- Jika tidak ada kode, tes selesai.
- Jika Kode kesalahan 116 muncul, menemukan kesalahan dalam pengujian, pergi ke Langkah 1.
- Jika kode selain 116 muncul, Lihat Kesalahan Daftar Kode Indeks.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]