Eaton Fuller Hybrid Kod pogreške 6 – No HCM Operation

Kod pogreške za Eaton Hybrid Drive Systems modeli (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P i EH-6E706B-UPG. Hibridni kontrolni modul (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

Kod pogreške 6 – No HCM Operation Detection

Sljedeće pretpostavke moraju biti ispunjeni prije nego što sistem detektuje greške:

  • HCM Napon paljenja je veći od 7 volta i manje od 16 volti.

Uslovi za Set Fault Kod Active

Uslovi za Set Fault:

  • MMF 12 is set at key on if the HCM detects an internal failure.
  • MMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Kada Kod pogreške 6 je postavljen dođe do sledećeg:
• Amber "hibrida" lampica.
• If the fault occurs at power up the vehicle may not crank.

Uslovi za Set Fault Kod Neaktivni

Samo Neaktivni greške mogu biti izbrisani iz Jedinice za Transmission Electronic Control (TECU) ili HCM povijest koristeći ServiceRanger. U TECU automatski briše greške iz istorije nakon 200 sati. HCM automatski briše greške iz istorije nakon kvara nije aktivan 200 sati.

Ovaj kod kvara može biti uzrokovan bilo koji od sljedećeg:

  • MMF 12, 14
    • HCM

Kod pogreške 6 – No HCM Operation Test