[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Гибрид Трансмиссия Код ошибки 90 – CAN BCU 2 Сообщение (HCM)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Код ошибки для Eaton гибридных моделей системы приводов (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-Т и EH-6E606B-CD. Читайте ниже, чтобы узнать, как проверить, очистить и исправить ошибки коды неисправности для Freightliner, Mack, Peterbilt, Kenworth, Volvo, Международный, и тяжелые грузовики и оборудование. Модуль Hybrid Control (HCM) связь с инвертором обменивается данными с блоком управления батареи (BCU) расположенный в силовой электронике Carrier (PEC) и HCM на сети контроллеров (МОЖНО) высокоскоростной ссылка собственности данные. Канал передачи данных представляет собой два провода витой пары с двумя 120 Ом резисторы, расположенные в ссылке.
код ошибки 90 – CAN BCU 2 Сообщение (HCM) обнаружение
Следующие предварительные условия должны быть выполнены до того, как система обнаружит ошибку:
- НСМ напряжения зажигания выше 7 вольт и меньше 16 вольт.
- Неисправность HCM линии передачи данных CAN Неактивный.
Заметка: При устранении неактивного кода обратитесь к Диагностический режим продукта (ДПМ)
Условия Установить Код ошибки Активный
- МВФ 9 устанавливается, когда HCM не получил BCU 2 сообщение для 30 последовательные циклы сообщений.
Запасной Когда код неисправности 90 установлено, что имеют место следующие условия:
- Amber «Проверить Гибридные» свет горит.
- Ошибка сохраняется в модуле управления гибридным (HCM) объем памяти.
- Электрический двигатель / генератор Assist и регенерации отключены; тем не мение, реле высокого напряжения остаются питание.
- НСМ продолжает контролировать гибридное транспортное средство в режиме дизель-только.
- по умолчанию начала передачи шестерни
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Условия указан код неисправности Inactive
Только Неактивные неисправности могут быть очищены от блока передачи электронного управления (TECU) или история HCM с использованием ServiceRanger. TECU автоматически удаляет информацию о неисправностях из истории после того, как 200 часы и HCM автоматически удаляет информацию о неисправностях из истории после сбоя были неактивными 200 часов.
Этот код неисправности может быть вызван любым из следующих:
- FMI9
- инвертор
- PEC
- CAN Канальный от ПЭК инверторные
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
код ошибки 90 – CAN BCU 2 Сообщение (HCM) Тестовое задание
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Идентификация компонентов:
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”10%” padding_bottom=”” padding_left=”10%”][fusion_builder_row][fusion_builder_column type=”1_3″ layout=”1_3″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Гибридный разъем интерфейса системы” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Жгут Вид спереди
(HCM – Гибридный разъем интерфейса системы)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_3″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14474|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Delphi 56-Way Ответный разъем Вид для передачи Eaton Fuller” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-56-Way-Mating-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Delphi 56-Way переходник Просмотр
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_3″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14213|medium” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”PEC – Низкий Разъем напряжения” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
PEC – Низкий Разъем напряжения
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
НОТА: Обратитесь к Eaton Гибридные компоненты и разъем Расположение местоположения коннекторов в MY08 системах
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14502|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Фуллер передачи НСМ инвертора PEC Соединители” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-Inverter-PEC-Connector.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”Предупреждения & Предостережения” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Опасность: Опасность означает, что вы будете серьезно ранены или убиты, если не следовать указанной процедуре.
Предупреждение: Предупреждение указывает на непосредственную опасность, что может привести к серьезным травмам, если не следовать указанной процедуре.
предосторожность: Внимание указывает на транспортное средство или повреждения имущества может произойти, если вы не следуете указанной процедуры.
Заметка: Примечание указывает дополнительную информацию, которая поможет в диагностике или ремонте компонентов системы /.
Выполните указанные процедуры в указанном порядке, чтобы избежать травм:
1. Если конусы высокого напряжения вокруг автомобиля и блокировка устанавливается на избирательном участке, единственный человек, который должен иметь возможность запуска автомобиля является лицом, подписавшим блокировочным тег.
2. Перед началом работы на транспортном средстве или выхода из кабины, когда двигатель работает, Вы должны поместить рычаг переключения передач в «N» установлен стояночный тормоз, и блокировать колеса.
3. По соображениям безопасности, всегда задействовать ножной тормоз до выбора позиции передач от «N.»
4. Перед тем как начать транспортное средство всегда сидит на сиденье водителя, выберите «N» на контроле сдвига, и установить стояночные тормоза.
5. В автомобилях с ePTO, двигатель и / или
Двигатель / генератор может начаться в режиме ePTO. Никогда не выполняйте техническое обслуживание или работать на транспортном средстве, в то время как в этом режиме.
6. 12-Volt батареи положительный (+) и отрицательные (-) должны быть отключены до любой сварки на любом Гибридная оборудованном автомобиле.
предосторожность: Выполните указанные процедуры в указанном порядке, чтобы избежать неисправностей или повреждения оборудования.
предосторожность: Не отпустить стояночный тормоз или пытаться выбрать передачу, пока давление воздуха не находится на должном уровне.
предосторожность: Для того, чтобы избежать повреждения трансмиссии во время буксировки переместите рычаг переключения передач в «N» и поднимите ведущие колеса от земли или отсоединять трансмиссию.
Предупреждения высокого напряжения & Предостережения
- Использование CO2 или сухих химических огнетушителей.
- Провода высокого напряжения покрываются в оранжевых изоляциях или свернутых насосно-компрессорных трубах и отмечены предупреждающими надписи на разъемах.
- Все Eaton® Гибридные Дизельные / Электрические автомобили будут помечены как «Hybrid’ на внешней стороне транспортного средства, наряду с ярлыком сдвига на приборной панели.
- Обратитесь к OEM для конкретного местоположения шасси установлена гибридных компонентов.
- Не режьте в оранжевые кабели высокого напряжения.
- НЕ нарезать или открыть PEC.
- НЕ нарезать или открыть преобразователь DC / DC.
- НЕ нарезать или открыть инвертор.
Буферная зона должна быть установлена и высокое напряжение изолированы резиновыми перчатки (учебный класс 0 кожаные протекторы) требуется до начала работы с высоким напряжением. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Резиновые теплозащитные перчатки, которые должны носить во время работы в системе высокого напряжения относятся к классу 0 кожаные протекторы. Резиновые перчатки должны быть проверены перед каждым использованием, следуя процедуре резиновой изоляции перчатки испытания нашли в «Средства диагностики / Сервис Публикации» на странице 6. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Перед осмотром или работать на любых кабелей или высоковольтных компонентов на «High-Voltage Shutdown Service и Power-Up Процедура» на странице 4 должны соблюдаться. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Устройства блокировки и Tagout должны быть удалены только с помощью техник, которые размещены устройства блокировки и Tagout на транспортном средстве. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Высоковольтные резиновой изоляцией перчатки (учебный класс 0 кожаные протекторы) следует носить при работе на любом
Кабели высокого напряжения. «Высоковольтный служба Shutdown и Power-Up Процедура» на странице 4 должен соблюдаться перед удалением любых кабелей высокого напряжения. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Кабели высокого напряжения и провод оранжевые цвета и содержат предупреждающий ярлык на разъемах. компоненты высокого напряжения помечены ярлыком. Высоковольтные резиновой изоляцией перчатки (учебный класс 0 кожаные протекторы) должны быть использованы при работе на любом из этих компонентов. Несоблюдение этих инструкций может привести к серьезным травмам или смерти.
Высоковольтные процедуры Service Shutdown
1. Следуйте «Высоковольтный Рабочая зона» Процедура.
2. Найдите красный PEC Service Switch на передней панели ПЭК и нажать выключить.
3. Снимите крышку Service Switch и установить кронштейн Lockout (J48506).
4. Закрепить тег локаута кронштейну.
5. Убедитесь, что переключатель PEC службы не может перейти от выключенного положения.
6. Дайте системе установить как минимум 5 минут разряда высокого напряжения.
7. Подключение ServiceRanger и просмотра монитора данных PID 116 под названием «High-Voltage потенциал батареи.» Использование SPN 520323 для подключения J1939 «Напряжение батареи RB» (коробка реле).
8. Напряжение должно быть 30 вольт или меньше. Если напряжение выше 30 вольт, не работают на транспортном средстве и связаться Eaton® на 1-800-826-HELP (4357).
9. Поверните ключ зажигания выключено и приступить к ремонту или устранение неполадок,.
Заметка: Напряжение падает до нуля, когда ключ выключен.
Высоковольтная служба включение питание Процедура
1. Установите все разъемы высокого напряжения в заблокированном состоянии.
2. Если вы человек, работающий на транспортном средстве, удалить Lockout кронштейн и тег.
3. Установите Lockout кронштейн через сервисный переключатель.
4. Вытащите Service Switch и дайте набор транспортных средств для 2 минут.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Гибридные компоненты и разъем Расположение ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Гибридные компоненты и разъем Расположение MY09 система” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 1.Verify статус активного и неактивного код неисправности.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Прочитайте больше” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Получить Активные коды неисправностей и ИФР с ServiceRanger помощью Диагностический разъем 9-Way или вручную.
- Выполните Электрическую Претест и гибридный электромобиль Претест:
- Если никаких проблем не обнаружено при гибридном электромобиле Претест, перейдите к шагу 2.
- Если проблема была восстановлена в течение гибридного электромобиля Претеста, перейдите к шагу 4.
[/fusion_content_box][fusion_content_box title=”ШАГ 2. Проверьте сопротивление CAN на избирательном участке 19-контактный разъем.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Прочитайте больше” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Ключ от.
Предупреждение: Увидеть Высоковольтная служба Shutdown и Энерговагоны процедуры. Выполните процедуры, чтобы избежать удара, ожог или смерть от неправильно обработанного высокого напряжения. - Отсоедините PEC 19-контактный разъем.
- Измерьте сопротивление между ПЭК 19-контактным разъемом Pin 1 и контактный 2:
Заметка: Убедитесь, что Вольт / Ом метр находится на соответствующем масштабе (вокруг 200 шкала Ом).- Если сопротивление между контактом 1 и контактный 2 находится между 50-70 Ом, заменить Power Electronics Carrier (PEC), затем перейдите к шагу 4.
- Если сопротивление находится вне диапазона, перейдите к шагу 3.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”ШАГ 3. Проверьте непрерывность на избирательном участке инверторного CAN Harness.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Инвертор Отсоедините 56-контактный разъем.
- Измерьте сопротивление между:
- Инвертор 56-контактный соединительный разъем 28 и PEC 19- Путь штекеры 2.
- Инвертор 56-контактный соединительный разъем 14 и PEC 19- Путь штекеры 1.
Заметка: Убедитесь, что Вольт / Ом метр находится на соответствующем масштабе (вокруг 200 шкала Ом). Заметка: Аккуратно согните инвертор 56-контактный разъем жгута проводов рядом с разъемом, контролируя значения сопротивления.- Если сопротивление между контактом 28 и контактный 2 между 0-0,2 Ом, и сопротивление между контактом 14 и контактный 1 между 0-0,2 Ом, заменить инвертор, затем перейдите к шагу 4.
- Если сопротивление находится вне диапазона, ремонт CAN Канальная Проводка между инвертором и ПЭКОМ, затем перейдите к шагу 4.
[/fusion_content_box][fusion_content_box title=”ШАГ 4. Проверка ремонта.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Прочитайте больше” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Ключ от.
- Подключите все разъемы и отрицательный кабель аккумулятора.
- Ключ на.
- Очистить коды, увидеть Очистить Неактивные Отказы.
- Водить автомобиль и попытаться сбросить код.
- Проверьте коды, увидеть Активные и неактивные разломы.
- Если нет кодов, Тест завершен.
- Если код неисправности 90 появляется, найти ошибку в тестировании, перейдите к шагу 1.
- Если код, отличный от 90 появляется, увидеть Неисправность Список индексов код.