[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Převodovka chybový kód 50 – J1939 Tělo Controller Message (HCM)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Porucha kód pro Eaton hybridních modelů Systém pohonů (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P a EH-6E706B-UPG. Přečtěte si níže se dozvíte, jak testovat, vyčistit a opravit chyby chybový kód pro Freightliner, gumák, Peterbilt, Kenworth, Volvo a Mezinárodní kamionová. J1939 je vysokorychlostní kroucený pár 250K datového spojení s jedním 120 ohm odpor na každém konci linky. Hybrid Control Module (HCM) connects to the J1939 data link at the 38-Way Connector. This link transmits information to the HCM and communicates with the other modules on the network such as the Body Controller.

chybový kód 50 – J1939 Tělo Controller Message (HCM) odhalení

Tyto předpoklady musí být splněny dříve, než systém detekuje poruchu:

  • HCM Napětí zapalování je vyšší než 7 voltů a méně než 16 voltů.

Poznámka: Při odstraňování neaktivní kód odkazovat na Režim produkt Diagnostic (PDM)

Podmínky Set Code Fault Active

  • IMF 9 is set when the HCM fails to receive Body Controller data for 5 s nebo větší, while it is still communicating with other modules on J1939.

Fallback-li chybový kód 50 je nastaven jsou splněny tyto podmínky:

  • Amber and red lights do not illuminate since the Body Controller activates the lights.
  • Porucha je uložen v paměti HCM.
  • HCM disables ePTO operation, since parameters like hydraulic demand are unavailable.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Podmínky, kterým je nastavený jako chybový kód deaktivovat

Pouze Neaktivní závady mohou být vymazány z oddělení Transmission Control Electronic (TECU) nebo HCM historie pomocí ServiceRanger. TECU automaticky vymaže chyby z historie po 200 hodiny a HCM automaticky vymaže chyby z historie po poruše je neaktivní 200 hodiny.

Tento chybový kód může být způsoben některou z následujících:

  • IMF 2, 9
    • J9139 Data Link
    • tělo Controller

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

chybový kód 50 – J1939 Tělo Controller Message (HCM) Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

komponenta Identifikace:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14061|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Interface Vehicle Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness Pohled zepředu
(HCM – Interface Vehicle Connector)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14251|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=Eaton Fuller transmission body controller HCM conncectorlink=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-transmission-body-controller-HCM-conncector.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”varování & Upozornění” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Nebezpečí: Nebezpečí znamená, budete vážně zraněn nebo zabit, pokud nenásledují uvedený postup.
Varování: Varování znamená bezprostřední ohrožení, což by mohlo vést k vážnému zranění, pokud nechcete sledovat označenou postup.
Pozor: Pozor označuje poškození vozidla nebo vlastnost by mohla nastat, pokud nechcete sledovat označenou postup.

Poznámka: Poznámka ukazuje další podrobnosti, které se při diagnostice nebo opravu konstrukční části / systému.

Postupujte podle uvedených pokynů v uvedeném pořadí, aby nedošlo k poranění:

1. V případě, že kužely vysokého napětí se pohybují kolem vozu a blokování je nainstalován na PEC, jediný člověk, který by měl být povolen start vozidla je osoba, která podepsala uzamčení značku.
2. Před zahájením prací na vozidle nebo opuštění kabiny, když je motor v chodu, měli byste umístit řadicí páku na „N“ zatáhnout parkovací brzdu, a zablokování kola.
3. Z bezpečnostních důvodů, vždy v záběru s provozní brzdy před výběrem převodových poloh od „N.“
4. Před zahájením vozidlo bude vždy sedět na sedadle řidiče, zvolte „N“ na ovládací prvek směny, a nastavení parkovací brzdy.
5. Ve vozidlech s ePTO, motor a / nebo
Motor / generátor může spustit v režimu ePTO. Nikdy neprovádějte údržbu nebo práce na vozidle, V tomto režimu.
6. 12-Volt Battery pozitivní (+) a negativní (-) musí být odpojen před každým svařováním na libovolné hybridního vozidla vybavená.

Pozor: Postupujte podle uvedených postupů v uvedeném pořadí, aby se zabránilo poruše nebo poškození zařízení.
Pozor: Neuvolňují parkovací brzdu nebo se pokusit zvolit rychlostní stupeň, dokud je tlak vzduchu na správné úrovni.
Pozor: Aby se zabránilo poškození převodovky při jízdě Umístěte řadicí páku do „N“ a zvedněte hnací kola nad zem, nebo odpojit hnací ústrojí.

High-napětí Varování & Upozornění

  • Používat CO2 nebo suchý chemický hasící zařízení.
  • vedení vysokého napětí se vztahuje na oranžovou izolací nebo svinutých potrubních a označených výstražnými štítky na konektorech.
  • Všechny Eaton® Hybridní diesel / Elektromobily budou označeny jako ‚Hybrid’ Na vnější straně vozidla, spolu s označením posunu na palubní desce.
  • Viz OEM pro specifické umístění podvozku namontována hybridních součástek.
  • Neřežte do oranžových vysokonapěťových kabelů.
  • Neřežte do nebo otevřít PEC.
  • Neřežte do nebo otevřete DC / DC konvertor.
  • NOT nakrájíme nebo otevření střídače.

Vyrovnávací zóna musí být nastaven a vysokého napětí izolované gumové rukavice (třída 0 s koženými chrániči) jsou povinni před zahájením práce na vysokého napětí. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Gumové rukavice izolací, které musí být nošeny při práci na systému vysokého napětí jsou class 0 s koženými chrániči. Gumové rukavice by měly být testovány před každým použitím následujícího postupu gumové rukavice izolace testování nalezené v „Diagnostické nástroje / Servisní publikace“ na straně 6. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Před kontrolou nebo prací na jakýchkoliv vysokonapěťových kabelů nebo komponentů na „High-Voltage Service vypnutí a Power-up procedura“ na straně 4 by měly být dodržovány. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Zařízení Lockout a Tagout by měly být odstraněny pouze technik, který umístil zařízení uzamčení a přívěsným štítkem na vozidle. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí nosit při práci na jakýkoli
vysokonapěťové kabely. „Služba Shutdown High-Voltage a Power-Up procedura“ na straně 4 musí být před a následně k odstranění jakýchkoliv vysokonapěťové kabely. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
kabely vysokého napětí a rozvody jsou oranžové a obsahují varovný štítek na konektory. Komponenty s vysokým napětím jsou označeny štítkem. Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí být použit při práci s některou z těchto složek. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.

High-napětí Service vypnutí Postupy

High-Voltage Service Shutdown a postup Power-Up1. Sledujte „Voltage High-Work Area“ procedura.
2. Vyhledejte červenou PEC servisní vypínač na přední straně PEC a tlačit vypnout.
3. Odstraňte Service Kryt vypínače a nainstalovat uzamčení držák (J48506).
4. Připevněte tag k uzamčení závorka.
5. Ujistěte se, že přepínač PEC služby nelze přesunout z polohy vypnuto.
6. Nechte systém nastaven na minimum 5 minut k vybití vysokého napětí.
7. Připojte ServiceRanger a zobrazení dat monitoru PID 116 s názvem „High-Voltage potenciál baterie.“ Use SPN 520323 pro připojení J1939 „Battery Voltage RB“ (Relay Box).
8. Napětí by mělo být 30 voltů nebo méně. Je-li napětí vyšší než 30 voltů, nefungují na vozidle a kontaktní Eaton® na 1-800-826-HELP (4357).
9. Otočte klíčkem zapalování vypnout a pokračovat opravit nebo krok řešení potíží.
Poznámka: Napětí klesne na nulu, když je klíč off.

High-Voltage Service Power-Up Postup

1. Nainstalovat všechny konektory s vysokým napětím do jejich uzamčených poloh.
2. Jste-li osoba, která pracuje na vozidle, odebrat uzamčení držáku a značku.
3. Přeinstalovat uzamčení konzoly přes hlavní vypínač.
4. Vytáhněte hlavní vypínač a dejte set vozidel pro 2 minut.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid komponent a konektorů Umístění ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent a konektorů Umístění MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid komponent a konektorů Umístění MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent a konektorů Umístění MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 1. Verify Active or Inactive fault code status.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Načíst aktivní chybové kódy a FMIS s ServiceRanger pomocí 9-Way diagnostického konektoru.
    • Pokud se kód poruchy 50 je aktivní, concern is either with the Body Controller or the Data Link from Body Controller to J1939 Data Link Backbone. Viz OEM k postupu opravy.
    • Pokud se kód poruchy 50 Neaktivní, dokončení testu.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]