[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller hybride transmissie Fault Code 35 – J1939 Communication Link (TECU)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Storing code voor Eaton Hybrid Drive Systems modellen (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-E / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P en EH-6E706B-UPG. 1939 een snelle twisted pair 250K datalink één 120 ohm weerstand aan elke kant van de verbinding. De Unit Transmission Electronic Control (TECU) is aangesloten op de J1939 data link aan de 38-polige stekker. Deze koppeling wordt gebruikt om informatie te verzenden naar de Hybrid Control Module (HCM) evenals communiceren met of gegevens ontvangen van de andere modules op het netwerk, zoals de Unit Electronic Control (eCU).

Fout code 35 – J1939 Communication Link (TECU) opsporing

De volgende randvoorwaarden moet worden voldaan voordat het systeem de fout detecteert:

  • TECU ontsteekspanning groter is dan 7 volt en minder dan 16 volt.
  • TECU Batterij bijna leeg fout is Inactief.

Voorwaarden voor Set Fault Code Active

  • IMF 2 wordt ingesteld wanneer de TECU verliest communicatie met alle modules op de J1939 data link voor 5 of meer seconden.

Terugval Als Fault Code 35 ingesteld gebeurt het volgende:

  • Red “Service” brandt en een “F” knippert in het versnellingsweergave.
  • Storing wordt opgeslagen in TECU geheugen.
  • De werkingsmodus verandert in autoshift terugvalmodus.
  • Als de storing wordt bij het opstarten, de motor draait niet.
  • Als de storing sets tijdens het rijden, blijft het voertuig in de huidige versnelling en de koppeling wordt geopend wanneer de snelheid van het voertuig benadert stationair.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Voorwaarden voor Set Fault Code Inactieve

Alleen Inactieve fouten kunnen worden gewist uit de Unit Transmission Electronic Control (TECU) of HCM geschiedenis met behulp ServiceRanger. De TECU verdwijnt automatisch de fouten uit de geschiedenis na 200 uur en de HCM verdwijnt automatisch de fouten uit de geschiedenis na de storing actief is geweest voor 200 uur.

Deze fout code kan worden veroorzaakt door een van de volgende:

  • IMF 2
    • J1939 Data Link
    • TECU

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fout code 35 – J1939 Communication Link (TECU) Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Identificatie van de onderdelen:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”2_3layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14135|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton transmission front Harness View TECU – Voertuig Interface Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Harness-Front-View-TECU-Vehicle-Interface-Connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Voorzijde Harness View
TECU – Voertuig Interface Connector

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14191|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Fuller 9-polige diagnose-aansluiting” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-9-way-Diagnostic-Connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

9-manier Diagnostic Connector

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTITIE: Verwijs naar de Eaton Hybrid Component en aansluiting Plaats voor Connector Locaties in MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTITIE: Verwijs naar de Eaton Hybrid Component en aansluiting Plaats voor Connector Locaties in MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14192|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”TECU naar 9 weg diagnostische connector Eaton Fuller transmissie” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/TECU-to-9-way-diagnostic-connector.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”waarschuwingen & waarschuwingen” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Gevaar: Gevaar betekent zult u ernstig gewond raken of gedood als niet de aangegeven procedure niet volgen.
Waarschuwing: Waarschuwing duidt op een onmiddellijk gevaar, die kan leiden tot ernstig persoonlijk letsel als je niet de aangegeven procedure te volgen.
Voorzichtigheid: Let op geeft voertuig of materiële schade zou kunnen ontstaan ​​als je niet de aangegeven procedure te volgen.

Notitie: Note geeft bijkomende details die helpen bij de diagnose of reparatie van een onderdeel / systeem.

Volg de voorgeschreven procedures in de aangegeven volgorde om persoonlijk letsel te voorkomen:

1. Als het hoogspanningsnet kegels zijn rond het voertuig en de lock-out is geïnstalleerd op de PEC, de enige persoon die moet worden toegestaan ​​om het voertuig te starten is de persoon die de lockout tag ondertekend.
2. Voor werkzaamheden aan een voertuig of de cabine te verlaten, terwijl de motor loopt, moet u de versnellingspook in “N” plaatsen trek de handrem, en blokkeren de wielen.
3. Voor veiligheidsredenen, altijd de bedrijfsremmen aangrijpen vóór selectie schakelstanden van “N.”
4. Voordat u begint met een voertuig altijd zitten in de bestuurdersstoel, Selecteer “N” op de schakelbesturingsinrichting, en stel de handrem.
5. In voertuigen met EPTO, de motor en / of
Motor / Generator kan starten in EPTO modus. Voer nooit onderhoud of werken aan het voertuig, In deze modus.
6. 12-Volt batterij positief (+) en negatieve (-) moet vooraf worden losgekoppeld laswerkzaamheden op een hybride voertuig uitgerust.

Voorzichtigheid: Volg de voorgeschreven procedures in de aangegeven volgorde om apparatuur storingen of schade te voorkomen.
Voorzichtigheid: Laat de parkeerrem niet vrijgeven of een poging om een ​​versnelling te selecteren totdat de luchtdruk op het juiste niveau.
Voorzichtigheid: Om beschadiging van de transmissie tijdens het slepen plaats de schakelhefboom in “N” te vermijden en til de aandrijfwielen van de grond en koppel de aandrijflijn.

High-Voltage Waarschuwingen & waarschuwingen

  • Gebruik CO2 of Dry Chemical Brandblussers.
  • De hoogspanning bedrading bedekt met oranje isolatie of gekronkelde slangen en aangegeven met waarschuwingen op de connectoren.
  • Alle Eaton® Hybride Diesel / Elektrische voertuigen zullen worden gemarkeerd als ‘Hybrid’ aan de buitenzijde van het voertuig, samen met de verschuiving label op het dashboard.
  • Raadpleeg OEM voor specifieke locatie van het chassis gemonteerde hybridecomponenten.
  • Knip niet in de oranje hoogspanningskabels.
  • Niet snijden in of open de PEC.
  • Knip niet in of de DC / DC-converter te openen.
  • Niet snijden in of open de Inverter.

Een bufferzone moet worden opgezet en hoogspanningsinstallaties geïsoleerde rubberhandschoenen (klasse 0 met lederen beschermers) zijn voorafgaand moeten aan hoogspanning. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
De rubber isolerende handschoenen die moeten worden gedragen tijdens het werken op de high-voltage systeem zijn klasse 0 met lederen beschermers. De rubberen handschoenen moeten worden getest voor elk gebruik na de rubberen isolatie handschoenen testprocedure vinden in “Diagnostic Tools / Dienst Publicaties” op pagina 6. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Voordat het inspecteren of werken op elk hoogspanningskabels of onderdelen van het “High-Voltage service Shutdown en Power-Up procedure” op pagina 4 moet worden gevolgd. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
De Lockout en Tagout apparaten mag alleen worden verwijderd door de technicus die de Lockout en Tagout op het voertuig geplaatst. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Hoogspanning rubber isolerende handschoenen (klasse 0 met lederen beschermers) moet gedragen worden bij het werken op een
hoogspanningskabels. De “High-Voltage service Shutdown en Power-Up procedure” op pagina 4 moet voor worden gevolgd om het verwijderen van hoogspanningskabels. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.
Hoogspanningskabels en bedrading zijn oranje en voorzien van een waarschuwingslabel op de connectoren. Hoogspanningsonderdelen worden gemarkeerd met een label. Hoogspanning rubber isolerende handschoenen (klasse 0 met lederen beschermers) moeten worden bij het werken op een van deze componenten. Het negeren van deze instructies kan leiden tot ernstig persoonlijk letsel of de dood.

High-Voltage Dienst Uitschakelprocedures

High-Voltage service Shutdown en Power-Up Procedure1. Volg de “High-Voltage Work Area” -procedure.
2. Zoek de rode PEC Dienst Switch aan de voorzijde van de PEC en druk uit te schakelen.
3. Verwijder de Dienst Switch Cover en installeer de Lockout Bracket (J48506).
4. Bevestig tag aan de Lockout Bracket.
5. Zorg ervoor dat de PEC Dienst Switch kan niet verplaatsen van de uit-stand.
6. Laat het systeem in te stellen voor een minimum van 5 minuten hoogspanningsontlading.
7. Sluit ServiceRanger en bekijk de Data Monitor PID 116 genaamd “High-Voltage Potential Battery.” Gebruik SPN 520323 voor J1939 aansluiting “Battery Voltage RB” (relaiskast).
8. De spanning moet 30 volt of minder. Indien de spanning boven 30 volt, werken niet op het voertuig en neem contact op Eaton® bij 1-800-826-HELP (4357).
9. Draai de contactsleutel uit en ga verder met repareren of stap het oplossen van problemen.
Notitie: De spanning daalt tot nul wanneer de sleutel uit.

High-Voltage dienst Power-Up Procedure

1. Installeer alle high-voltage connectoren in hun vergrendelde positie.
2. Als je de persoon die werkzaamheden aan het voertuig, verwijder de Lockout Bracket en tag.
3. Installeer de Lockout beugel over de Dienst Switch.
4. Trek de Dienst Schakel uit en laat het voertuig set voor 2 notulen.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Component en aansluiting Plaats ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Component en locaties van de aansluiting MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Component en aansluiting Plaats MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Component en locaties van de aansluiting MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 1. Controleer op actief of inactief foutcode de status.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Ophalen Actieve foutcodes en FMIS met ServiceRanger met behulp van de 9-polige diagnose-aansluiting.
  2. sleutel op.
  3. Selecteer het scherm “Vehicle Components” en bekijk de verschillende modules rapportage over de J1939 koppeling:
    • Als de TECU niet rapporteert J1939, maar de HCM wordt vermeld, ga dan naar stap 2.
    • Indien noch de HCM noch de TECU zijn rapportage op J1939, ga dan naar stap 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 2. Controleer de continuïteit van de Vehicle Interface circuits.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Koppel de negatieve kabel van de accu.
  3. Disconnect TECU Vehicle Harness 38- verbindingselement.
  4. Measure resistance between TECU Vehicle Harness 38- Way Connector Pin 2 en Pin 3:Notitie: Zorg ervoor dat de Volt / Ohm Meter is op de
    Notitie: Zorg ervoor dat de Volt / Ohm Meter is op de juiste schaal (rond 200ohm schaal).

    • Als weerstand tussen Pin 2 en Pin 3 tussen 50-70 ohm, vervang Transmission Electronic Control Unit (TECU), ga dan naar stap 5.
    • Als de weerstand buiten bereik, het herstel van de J1939 Datalink Harness, ga dan naar stap 5.

[/fusion_content_box][fusion_content_box title=STAP 3. Controleer de continuïteit van de transmissie Harness diagnoseconnector.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Meet weerstand tussen de diagnoseconnector 9-Way Pin C en pin D.If weerstand tussen pin pin C en D tussen 50-70 ohm, ga dan naar stap 4.
    • Als de weerstand 70 ohm of meer, één of meer van de afsluitweerstanden op de J1939 Data Link Harness ontbreekt of buiten bereik, of er is een open in de verbinding. Ga naar stap 5.
    • Als de weerstand 50 ohm of minder, Er is een extra afsluitweerstand aanwezig. Repareer de OEM J1939 Data Link Harness, ga dan naar stap 5.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 4. Controleer de continuïteit van de transmissie Harness diagnoseconnector circuits met aarde.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Meet de weerstand tussen de volgende 9- Way Diagnostic Connector Pins:
    • Pin C aan de grond
    • Pins D aan de grond
      • Als weerstand tussen pin C met aarde en pin D aan massa beide 10K ohm of meer, trachten te communiceren met een ander voertuig om ervoor te zorgen ServiceRanger werkt. Als ServiceRanger niet in slaagt om te communiceren met een ander voertuig, call 1-800-826-HELP (4357).
      • Als de weerstand buiten bereik, repareren J1939 Data Link Harness voor een korte aan de grond, ga dan naar stap 5.

[/fusion_content_box][fusion_content_box title=STAP 3. Controleer of reparatie.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees verder” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Sluit alle stekkers en negatieve accukabel.
  3. sleutel op.
  4. Clear codes, zien Clear Inactieve Storingen.
  5. Het voertuig rijdt en probeer de code opnieuw in te stellen.
  6. Controleer op codes, zien Toon actieve en inactieve Storingen.
    • Als er geen codes, test is voltooid.
    • Als fout Code 35 komt naar voren, vind fout bij het testen, ga dan naar stap 1.
    • Als een code anders dan 35 komt naar voren, zien Storing Code Index List.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]