[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Převodovka chybový kód 35 – J1939 Komunikace Link (TECU)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Porucha kód pro Eaton hybridních modelů Systém pohonů (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P a EH-6E706B-UPG. 1939 je vysokorychlostní kroucený pár 250K datového spojení s jedním 120 ohm odpor na každém konci linky. Jednotka Transmission Control Electronic (TECU) je připojen k odkazu J1939 dat na 38-Way Connector. Tento odkaz se používá k přenosu informací k Hybrid Control Module (HCM) stejně jako komunikovat s nebo přijímat data z ostatních modulů v síti, jako je například jednotka elektronické kontroly (ECU).

chybový kód 35 – J1939 Komunikace Link (TECU) odhalení

Tyto předpoklady musí být splněny dříve, než systém detekuje poruchu:

  • TECU Napětí zapalování je vyšší než 7 voltů a méně než 16 voltů.
  • TECU Battery Voltage Low porucha Neaktivní.

Podmínky Set Code Fault Active

  • IMF 2 je nastaven, když je TECU ztratí komunikaci se všemi moduly na odkaz J1939 dat pro 5 nebo více sekund.

Fallback-li chybový kód 35 je nastaven jsou splněny tyto podmínky:

  • Červené „Servis“ se rozsvítí a bliká „F“ na displeji převodovky.
  • Porucha je uložen v paměti TECU.
  • Provozní režim se změní na režim Autoshift fallback.
  • Pokud porucha nastaví při zapnutí, Motor nebude klikat.
  • Pokud dojde k závadě sad při jízdě, zůstane vozidlo v aktuální převodový stupeň a spojka se vypne, když je rychlost vozidla přiblíží volnoběhu.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Podmínky, kterým je nastavený jako chybový kód deaktivovat

Pouze Neaktivní závady mohou být vymazány z oddělení Transmission Control Electronic (TECU) nebo HCM historie pomocí ServiceRanger. TECU automaticky vymaže chyby z historie po 200 hodiny a HCM automaticky vymaže chyby z historie po poruše je neaktivní 200 hodiny.

Tento chybový kód může být způsoben některou z následujících:

  • IMF 2
    • J1939 Data Link
    • TECU

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

chybový kód 35 – J1939 Komunikace Link (TECU) Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

komponenta Identifikace:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”2_3layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14135|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”převodovka Eaton Front Harness View TECU – Interface Vehicle Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Harness-Front-View-TECU-Vehicle-Interface-Connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Přední Harness View
TECU – Interface Vehicle Connector

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14191|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Fuller 9-způsob diagnostického konektoru” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-9-way-Diagnostic-Connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

9-způsob diagnostického konektoru

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14192|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”TECU na 9 způsob diagnostický konektor pro přenos Eaton Fuller” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/TECU-to-9-way-diagnostic-connector.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”varování & Upozornění” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Nebezpečí: Nebezpečí znamená, budete vážně zraněn nebo zabit, pokud nenásledují uvedený postup.
Varování: Varování znamená bezprostřední ohrožení, což by mohlo vést k vážnému zranění, pokud nechcete sledovat označenou postup.
Pozor: Pozor označuje poškození vozidla nebo vlastnost by mohla nastat, pokud nechcete sledovat označenou postup.

Poznámka: Poznámka ukazuje další podrobnosti, které se při diagnostice nebo opravu konstrukční části / systému.

Postupujte podle uvedených pokynů v uvedeném pořadí, aby nedošlo k poranění:

1. V případě, že kužely vysokého napětí se pohybují kolem vozu a blokování je nainstalován na PEC, jediný člověk, který by měl být povolen start vozidla je osoba, která podepsala uzamčení značku.
2. Před zahájením prací na vozidle nebo opuštění kabiny, když je motor v chodu, měli byste umístit řadicí páku na „N“ zatáhnout parkovací brzdu, a zablokování kola.
3. Z bezpečnostních důvodů, vždy v záběru s provozní brzdy před výběrem převodových poloh od „N.“
4. Před zahájením vozidlo bude vždy sedět na sedadle řidiče, zvolte „N“ na ovládací prvek směny, a nastavení parkovací brzdy.
5. Ve vozidlech s ePTO, motor a / nebo
Motor / generátor může spustit v režimu ePTO. Nikdy neprovádějte údržbu nebo práce na vozidle, V tomto režimu.
6. 12-Volt Battery pozitivní (+) a negativní (-) musí být odpojen před každým svařováním na libovolné hybridního vozidla vybavená.

Pozor: Postupujte podle uvedených postupů v uvedeném pořadí, aby se zabránilo poruše nebo poškození zařízení.
Pozor: Neuvolňují parkovací brzdu nebo se pokusit zvolit rychlostní stupeň, dokud je tlak vzduchu na správné úrovni.
Pozor: Aby se zabránilo poškození převodovky při jízdě Umístěte řadicí páku do „N“ a zvedněte hnací kola nad zem, nebo odpojit hnací ústrojí.

High-napětí Varování & Upozornění

  • Používat CO2 nebo suchý chemický hasící zařízení.
  • vedení vysokého napětí se vztahuje na oranžovou izolací nebo svinutých potrubních a označených výstražnými štítky na konektorech.
  • Všechny Eaton® Hybridní diesel / Elektromobily budou označeny jako ‚Hybrid’ Na vnější straně vozidla, spolu s označením posunu na palubní desce.
  • Viz OEM pro specifické umístění podvozku namontována hybridních součástek.
  • Neřežte do oranžových vysokonapěťových kabelů.
  • Neřežte do nebo otevřít PEC.
  • Neřežte do nebo otevřete DC / DC konvertor.
  • NOT nakrájíme nebo otevření střídače.

Vyrovnávací zóna musí být nastaven a vysokého napětí izolované gumové rukavice (třída 0 s koženými chrániči) jsou povinni před zahájením práce na vysokého napětí. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Gumové rukavice izolací, které musí být nošeny při práci na systému vysokého napětí jsou class 0 s koženými chrániči. Gumové rukavice by měly být testovány před každým použitím následujícího postupu gumové rukavice izolace testování nalezené v „Diagnostické nástroje / Servisní publikace“ na straně 6. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Před kontrolou nebo prací na jakýchkoliv vysokonapěťových kabelů nebo komponentů na „High-Voltage Service vypnutí a Power-up procedura“ na straně 4 by měly být dodržovány. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Zařízení Lockout a Tagout by měly být odstraněny pouze technik, který umístil zařízení uzamčení a přívěsným štítkem na vozidle. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí nosit při práci na jakýkoli
vysokonapěťové kabely. „Služba Shutdown High-Voltage a Power-Up procedura“ na straně 4 musí být před a následně k odstranění jakýchkoliv vysokonapěťové kabely. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
kabely vysokého napětí a rozvody jsou oranžové a obsahují varovný štítek na konektory. Komponenty s vysokým napětím jsou označeny štítkem. Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí být použit při práci s některou z těchto složek. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.

High-napětí Service vypnutí Postupy

High-Voltage Service Shutdown a postup Power-Up1. Sledujte „Voltage High-Work Area“ procedura.
2. Vyhledejte červenou PEC servisní vypínač na přední straně PEC a tlačit vypnout.
3. Odstraňte Service Kryt vypínače a nainstalovat uzamčení držák (J48506).
4. Připevněte tag k uzamčení závorka.
5. Ujistěte se, že přepínač PEC služby nelze přesunout z polohy vypnuto.
6. Nechte systém nastaven na minimum 5 minut k vybití vysokého napětí.
7. Připojte ServiceRanger a zobrazení dat monitoru PID 116 s názvem „High-Voltage potenciál baterie.“ Use SPN 520323 pro připojení J1939 „Battery Voltage RB“ (Relay Box).
8. Napětí by mělo být 30 voltů nebo méně. Je-li napětí vyšší než 30 voltů, nefungují na vozidle a kontaktní Eaton® na 1-800-826-HELP (4357).
9. Otočte klíčkem zapalování vypnout a pokračovat opravit nebo krok řešení potíží.
Poznámka: Napětí klesne na nulu, když je klíč off.

High-Voltage Service Power-Up Postup

1. Nainstalovat všechny konektory s vysokým napětím do jejich uzamčených poloh.
2. Jste-li osoba, která pracuje na vozidle, odebrat uzamčení držáku a značku.
3. Přeinstalovat uzamčení konzoly přes hlavní vypínač.
4. Vytáhněte hlavní vypínač a dejte set vozidel pro 2 minut.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid komponent a konektorů Umístění ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent a konektorů Umístění MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid komponent a konektorů Umístění MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent a konektorů Umístění MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 1. Zkontrolujte, zda je stav aktivní nebo neaktivní chybových kódů.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Načíst aktivní chybové kódy a FMIS s ServiceRanger pomocí 9-Way diagnostického konektoru.
  2. klíčem k.
  3. Vyberte obrazovku „Vehicle Components“ a zobrazit různé moduly hlášení na linku J1939:
    • V případě, že TECU nic nehlásí na J1939, ale HCM je uvedena, přejděte ke kroku 2.
    • Nemají-li HCM ani TECU hlásí na J1939, přejděte ke kroku 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 2. Ověřit kontinuitu rozhraní vozidla obvodů.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Odpojte záporný kabel baterie.
  3. Disconnect TECU Vehicle Harness 38- way connector.
  4. Measure resistance between TECU Vehicle Harness 38- Way Connector Pin 2 a Pin 3:Poznámka: Ujistěte se, že Volt / Ohm metr je na
    Poznámka: Ujistěte se, že Volt / Ohm metr je na správném měřítku (asi 200ohm měřítku).

    • Pokud odpor mezi Pin 2 a Pin 3 se pohybuje v rozmezí 50-70 ohmů, vyměnit Transmission Elektronická řídicí jednotka (TECU), přejděte ke kroku 5.
    • Pokud je odpor mimo rozsah, Oprava propojení postroje J1939 dat, přejděte ke kroku 5.

[/fusion_content_box][fusion_content_box title=KROK 3. Ověřit kontinuitu diagnostického konektoru Převodovka postroj.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Změřte odpor mezi diagnostického konektoru 9-Way Pin C a odolnost proti Pin D.If mezi Pin C a Pin D se pohybuje v rozmezí 50-70 ohmů, přejděte ke kroku 4.
    • Pokud je odpor 70 ohmů nebo vyšší, jeden nebo více zakončovací odpory na J1939 Data Link svazku chybí nebo je mimo rozsah, nebo je tam otevřený v odkaze. Přejděte na krok 5.
    • Pokud je odpor 50 ohmů nebo méně, existuje další zakončovací odpor přítomen. Opravte OEM J1939 Data Link postroj, přejděte ke kroku 5.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=KROK 4. Ověřit kontinuitu Transmission postroj Diagnostický konektor obvodů na zem.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Změřte odpor mezi tímto 9- Way Diagnostický konektor Pins:
    • Pin C k zemi
    • Pin D na zem
      • Pokud je odpor mezi kontakt C k zemi a Pin D k zemi jsou oba 10K ohmů nebo větší, pokusí komunikovat s jiným vozidlem, aby zajistily ServiceRanger funguje. Pokud ServiceRanger nedokáže komunikovat s jiným vozidlem, volejte 1-800-826-HELP (4357).
      • Pokud je odpor mimo rozsah, opravovat J1939 Data Link postroj na zkrat na kostru, přejděte ke kroku 5.

[/fusion_content_box][fusion_content_box title=KROK 3. ověřte opravu.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Zapojte všechny konektory a záporný kabel akumulátoru.
  3. klíčem k.
  4. jasné kódy, vidět Jasné Neaktivní Závady.
  5. Projeďte vozidlo a pokusit se obnovit kód.
  6. Zkontrolujte, zda kódy, vidět Zobrazit aktivní a neaktivní Chyby.
    • Pokud žádné kódy, dokončení testu.
    • Pokud chybový kód 35 objeví se, najít chybu v testování, přejděte ke kroku 1.
    • Je-li kód jiný než 35 objeví se, vidět Porucha číselníku Rejstřík.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]