[fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Feilkode 22 – J1939 ABS Message Fault (HCM)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Feilkode for Eaton Hybrid Drive Systems modeller (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P og EH-6E706B-UPG. J1939 er en high-speed tvunnet par 250K datalink med ett 120 ohm motstand i hver ende av koblingen. HCM er koblet til J1939 Data Link på 38-Way Connector. Denne koblingen brukes til å overføre informasjon til HCM, så vel som å kommunisere eller motta data fra de andre modulene i nettverket som ABS-modulen.
Feilkode 22 – J1939 ABS Message Fault (HCM) Gjenkjenning
Følgende forutsetninger må være oppfylt før systemet oppdager feilen:
- HCM tennspenning er større enn 7 volt og mindre enn 16 volt.
- J1939 Data Link kommunikasjonsfeil er ikke aktiv.
Forhold som ligger Feilkode Aktiv
- IMF 9 settes når HCM ikke mottar ABS meldinger, og det er ingen aktive J1939 feil. I PDM-modus (IMF 2) denne feilen er satt hvis 3 påfølgende meldinger (EBC1) er ikke mottatt.
- IMF 14 settes når HCM mottar en aktiv ABS signal (SPN563) out of range or the ABS “Fully Operational Signal” (SPN1243) er ikke til stede for 1 sekund.
Fallback Når Feilkode 22 er satt følgende betingelser inntreffer:
- Amber “Sjekk Hybrid” lysinstallasjoner.
- Feilen lagres i HCM minne.
- Dersom det oppstår feil under flytting, operasjonsmodus går inn automatgir bare.
- Elektrisk motor / generator Assist og Regeneration er deaktivert; derimot, høy spenning releer forbli drevet.
- Overføringsstandarder begynne utstyr til første.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Denne feilkoden kan være forårsaket av en hvilken som helst av de følgende:
- IMF 2, 9
- J1939 Data Link
- ABS-modul
- IMF 14
- ABS-modul konfigurert for å kommunisere med J1708 eller analog i stedet for J1939.
- ABS-modulen rapporterer om en aktiv feil.
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Feilkode 22 – J1939 ABS Message Fault (HCM) Test
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identifikasjon av komponenter:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton overføring komponent identifisering” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Front Sele Vis
(HCM – Vehicle grensesnittkontakt)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
MERK: Referere til Eaton Hybrid Component og Connector Location for Kontakter.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14159|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton overføring ABS HCM kontakten” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-transmission-ABS-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”advarsler & Forsiktighetsregler” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Fare: Fare indikerer at du vil bli alvorlig skadet eller drept hvis ikke følger den angitte prosedyren.
Advarsel: Advarsel indikerer en umiddelbar fare, noe som kan føre til alvorlig personskade hvis du ikke følger den angitte prosedyren.
Forsiktighet: Forsiktig indikerer kjøretøy eller materielle skader kan oppstå hvis du ikke følger den angitte prosedyren.
Merk: Merk indikerer ytterligere detalj som vil understøtte diagnostisering eller reparasjon av en komponent / system.
Følg de angitte prosedyrene i angitt for å unngå personskader:
1. Ved høy spenning membranene er omkring kjøretøyet og sperren er montert på den anvendte PEF, den eneste personen som skal få lov til å starte bilen er den personen som signerte lockout tag.
2. Før du arbeider på et kjøretøy eller forlate førerhuset mens motoren er i gang, du bør plassere girspaken i “N” sett på parkeringsbremsen, og blokkere hjulene.
3. Av sikkerhetsmessige grunner, alltid i inngrep med bremser før velge girstillingene fra “N.”
4. Før du starter et kjøretøy alltid sitte i førersetet, velg “N” på girspaken, og sett på parkeringsbrems.
5. I biler med ePTO, motoren og / eller
Motor / Generator kan starte i ePTO modus. Utfør aldri vedlikehold eller arbeid på kjøretøy, mens i denne modusen.
6. 12-Volt Battery positiv (+) og negative (-) må koples fra før enhver sveising på en hvilken som helst hybrid utstyrt kjøretøy.
Forsiktighet: Følg de angitte prosedyrene i angitt for å unngå feil på utstyr eller skade.
Forsiktighet: Ikke slipp parkeringsbremsen eller forsøke å velge et gir til lufttrykket er på riktig nivå.
Forsiktighet: For å unngå skade på transmisjonen under slep sted girspaken i “N” og løfte drivhjulene av bakken eller frakoble drivlinjen.
Høyspent advarsler & Forsiktighetsregler
- Bruk CO2 eller kjemisk brannslukkere.
- Den høyspente ledninger er dekket i oransje isolasjon eller korrugert slange og merket med advarsler på kontaktene.
- Alle Eaton® Hybrid Diesel / elektriske biler vil bli merket med ‘Hybrid’ på utsiden av kjøretøyet, sammen med skift etiketten på dashbordet.
- Referer til OEM for en bestemt plassering av chassismontert hybrid komponenter.
- IKKE kutt i de oransje høyspenningskabler.
- IKKE kutt i eller åpne PEC.
- IKKE kutt i eller åpne DC / DC Converter.
- IKKE kutt i eller åpne Inverter.
En buffersone må settes opp og høy spenning isoleres gummihansker (klasse 0 med skinn beskyttere) Det kreves før arbeider på høy spenning. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Gummiisolerte hansker som må brukes ved arbeid med høy spenning system er klasse 0 med skinn beskyttere. Gummihansker bør testes før hver bruk etter gummi isolasjonshansker testprosedyren finnes i “Diagnostic Tools / tjeneste Publikasjoner” på side 6. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Før inspeksjon eller arbeider på noen høyspentkabler eller komponenter “High-Voltage service Shutdown og Power-Up Prosedyre” på side 4 bør følges. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Låsingen og Tagout enheter skal bare fjernes av teknikeren som plasseres på låse og Tagout anordninger på kjøretøyet. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Høyspente gummiisolerte hansker (klasse 0 med skinn beskyttere) må brukes når du arbeider på noen
høyspenningskabler. “High-Voltage service Shutdown og Power-Up Prosedyre” på side 4 må følges før fjerning av eventuelle høyspenningskabler. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Høyspentkabler og ledninger er oransje og inneholder en advarsel etikett på kontaktene. Høyspente komponenter er markert med en etikett. Høyspente gummiisolerte hansker (klasse 0 med skinn beskyttere) må brukes når du arbeider på noen av disse komponentene. Hvis du ikke følger disse instruksjonene kan føre til alvorlig personskade eller død.
Høyspent service avslåingsprosedyrer
1. Følg “High-Voltage Work Area” prosedyre.
2. Finn den røde PEC servicebryter på forsiden av PEC og presse slå av.
3. Fjern Tjenesten Switch Cover og installere Lockout Bracket (J48506).
4. Fest tag til Lockout Bracket.
5. Sørg for at PEC servicebryter kan ikke flytte fra seg stillingen.
6. La systemet for å sette i minst 5 minutter for å løsne høyspennings.
7. Koble ServiceRanger og vise data Monitor PID 116 kalt “High-Voltage Batteri Potential”. Bruk SPN 520323 for J1939-tilkobling “Battery Voltage RB” (Relay Box).
8. Spenningen skal være 30 volt eller mindre. Hvis spenningen er over 30 volt, fungerer ikke på kjøretøyet og ta kontakt Eaton® på 1-800-826-HELP (4357).
9. Vri tenningsnøkkelen av og fortsette å reparere eller trinn i feilsøkingen.
Merk: Spenningen faller til null når nøkkelen er off.
Høyspent service Strøm-Up Prosedyre
1. Installer alle høyspente kontakter inn i deres låste posisjoner.
2. Hvis du er den personen som arbeider på kjøretøyet, fjerne låsingen brakett og tag.
3. Sett på Lockout Bracket over servicebryter.
4. Trekk Tjenesten Bytt ut og la bilen satt for 2 minutter.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Component og Connector Location ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Component og Connector Location MY09 Systems” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”SKRITT 1. Se etter feilkode status Aktiv eller Inaktiv.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Les mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Retrieve the Active fault codes and FMIs with ServiceRanger using the 9-Way Diagnostic Connector.
- Hvilke FMIs er til stede?
- Hvis feilkode 22 IMF 9 er notert, Problemet er med Data Link Backbone ABS modul eller med J1939 Data Link fra ABS-modul til J1939. Refererer til OEM for reparasjon prosedyrer.
- Hvis feilkode 22 IMF 14 er notert, problem is with the Data Link ABS Module being configured for J1708 instead of J1939 communication, og / eller med ABS-modulen selv. Refererer til OEM for reparasjon prosedyrer.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]