[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Převodovka chybový kód 114 – Inverter Power Supply
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Porucha kód pro Eaton hybridních modelů Systém pohonů (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P a EH-6E706B-UPG. Přečtěte si níže se dozvíte, jak testovat, vyčistit a opravit chyby chybový kód pro Freightliner, gumák, Peterbilt, Kenworth, Volvo, Mezinárodní, a těžká nákladní automobil a vybavení. The Inverter assembly uses a 12V or 24V supply provided from the Hybrid Control Module (HCM) to power the Internal Control Board. The HCM provides ignition power to the Internal Control Board after it completes the power-up self-check.
chybový kód 114 – Detekce Inverter Power Supply
Tyto předpoklady musí být splněny dříve, než systém detekuje poruchu:
- Hybrid Control Module (HCM) Zapalovací napětí je větší než 7 voltů a méně než 16 voltů.
Poznámka: Při odstraňování neaktivní kód odkazovat na Režim produkt Diagnostic (PDM)
Podmínky Set Code Fault Active
- IMF 3 je nastaven, když napětí střídače zapalování je větší než 16 voltů pro 0.5 sekundy.
- IMF 4 je nastaven, když napětí střídače zapalování je menší než 7 voltů pro 0.1 sekundy.
Fallback-li chybový kód 114 je nastaven jsou splněny tyto podmínky:
- Jantaru „Check Hybrid“ se rozsvítí.
- Porucha je uložen v Hybrid Control Module (HCM) Paměť.
- Elektromotor / generátor Assist a regenerace jsou zakázány; nicméně, vysokonapěťové relé zůstává napájený.
- HCM nadále řídit hybridním pohonem v režimu vznětového pouze.
- Přenosové výchozí začít výbavu do 1..
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Podmínky, kterým je nastavený jako chybový kód deaktivovat
Pouze Neaktivní závady mohou být vymazány z oddělení Transmission Control Electronic (TECU) nebo HCM historie pomocí ServiceRanger. TECU automaticky vymaže chyby z historie po 200 hodiny a HCM automaticky vymaže chyby z historie po poruše je neaktivní 200 hodiny.
Tento chybový kód může být způsoben některou z následujících:
- IMF 1
- měnič
- IMF 3
- měnič
- IMF 4
- HCM
- měnič
- dodávka svazek napájení z měniče k HCM
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
chybový kód 114 – Inverter Power Supply test
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Komponentní Identifikační MY08 Systems:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Hybrid System Connector Interface” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Harness Pohled zepředu
(HCM – Hybrid System Connector Interface)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14474|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Měnič 56-Way páření konektor View” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-56-Way-Mating-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Měnič 56-Way páření konektor View
(měnič – Low Voltage Connector)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY08 Systems
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14650|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM měniče k konektor pro přenos Eaton Fuller” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-to-Inverter-MY08.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”20″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Komponentní Identifikační MY09 Systems:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Hybrid System Connector Interface” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Harness Pohled zepředu
(HCM – Hybrid System Connector Interface)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14476|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40 cestný pohled připojovacího konektoru” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Deutsch 40-Way páření konektor View
(měnič – Low Voltage Connector)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
POZNÁMKA: Odkazovat na Eaton Hybrid komponent a konektorů Umístění pro konektory místech v MY09 Systems.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14651|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM měniče k umístění konektoru pro Fuller přenosové MY09″ link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-to-Inverter-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”varování & Upozornění” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Nebezpečí: Nebezpečí znamená, budete vážně zraněn nebo zabit, pokud nenásledují uvedený postup.
Varování: Varování znamená bezprostřední ohrožení, což by mohlo vést k vážnému zranění, pokud nechcete sledovat označenou postup.
Pozor: Pozor označuje poškození vozidla nebo vlastnost by mohla nastat, pokud nechcete sledovat označenou postup.
Poznámka: Poznámka ukazuje další podrobnosti, které se při diagnostice nebo opravu konstrukční části / systému.
Postupujte podle uvedených pokynů v uvedeném pořadí, aby nedošlo k poranění:
1. V případě, že kužely vysokého napětí se pohybují kolem vozu a blokování je nainstalován na PEC, jediný člověk, který by měl být povolen start vozidla je osoba, která podepsala uzamčení značku.
2. Před zahájením prací na vozidle nebo opuštění kabiny, když je motor v chodu, měli byste umístit řadicí páku na „N“ zatáhnout parkovací brzdu, a zablokování kola.
3. Z bezpečnostních důvodů, vždy v záběru s provozní brzdy před výběrem převodových poloh od „N.“
4. Před zahájením vozidlo bude vždy sedět na sedadle řidiče, zvolte „N“ na ovládací prvek směny, a nastavení parkovací brzdy.
5. Ve vozidlech s ePTO, motor a / nebo
Motor / generátor může spustit v režimu ePTO. Nikdy neprovádějte údržbu nebo práce na vozidle, V tomto režimu.
6. 12-Volt Battery pozitivní (+) a negativní (-) musí být odpojen před každým svařováním na libovolné hybridního vozidla vybavená.
Pozor: Postupujte podle uvedených postupů v uvedeném pořadí, aby se zabránilo poruše nebo poškození zařízení.
Pozor: Neuvolňují parkovací brzdu nebo se pokusit zvolit rychlostní stupeň, dokud je tlak vzduchu na správné úrovni.
Pozor: Aby se zabránilo poškození převodovky při jízdě Umístěte řadicí páku do „N“ a zvedněte hnací kola nad zem, nebo odpojit hnací ústrojí.
High-napětí Varování & Upozornění
- Používat CO2 nebo suchý chemický hasící zařízení.
- vedení vysokého napětí se vztahuje na oranžovou izolací nebo svinutých potrubních a označených výstražnými štítky na konektorech.
- Všechny Eaton® Hybridní diesel / Elektromobily budou označeny jako ‚Hybrid’ Na vnější straně vozidla, spolu s označením posunu na palubní desce.
- Viz OEM pro specifické umístění podvozku namontována hybridních součástek.
- Neřežte do oranžových vysokonapěťových kabelů.
- Neřežte do nebo otevřít PEC.
- Neřežte do nebo otevřete DC / DC konvertor.
- NOT nakrájíme nebo otevření střídače.
Vyrovnávací zóna musí být nastaven a vysokého napětí izolované gumové rukavice (třída 0 s koženými chrániči) jsou povinni před zahájením práce na vysokého napětí. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Gumové rukavice izolací, které musí být nošeny při práci na systému vysokého napětí jsou class 0 s koženými chrániči. Gumové rukavice by měly být testovány před každým použitím následujícího postupu gumové rukavice izolace testování nalezené v „Diagnostické nástroje / Servisní publikace“ na straně 6. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Před kontrolou nebo prací na jakýchkoliv vysokonapěťových kabelů nebo komponentů na „High-Voltage Service vypnutí a Power-up procedura“ na straně 4 by měly být dodržovány. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Zařízení Lockout a Tagout by měly být odstraněny pouze technik, který umístil zařízení uzamčení a přívěsným štítkem na vozidle. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí nosit při práci na jakýkoli
vysokonapěťové kabely. „Služba Shutdown High-Voltage a Power-Up procedura“ na straně 4 musí být před a následně k odstranění jakýchkoliv vysokonapěťové kabely. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
kabely vysokého napětí a rozvody jsou oranžové a obsahují varovný štítek na konektory. Komponenty s vysokým napětím jsou označeny štítkem. Vysokonapěťové v gumové rukavice (třída 0 s koženými chrániči) musí být použit při práci s některou z těchto složek. Nedodržení těchto pokynů může vést k vážnému zranění nebo smrti.
High-napětí Service vypnutí Postupy
1. Sledujte „Voltage High-Work Area“ procedura.
2. Vyhledejte červenou PEC servisní vypínač na přední straně PEC a tlačit vypnout.
3. Odstraňte Service Kryt vypínače a nainstalovat uzamčení držák (J48506).
4. Připevněte tag k uzamčení závorka.
5. Ujistěte se, že přepínač PEC služby nelze přesunout z polohy vypnuto.
6. Nechte systém nastaven na minimum 5 minut k vybití vysokého napětí.
7. Připojte ServiceRanger a zobrazení dat monitoru PID 116 s názvem „High-Voltage potenciál baterie.“ Use SPN 520323 pro připojení J1939 „Battery Voltage RB“ (Relay Box).
8. Napětí by mělo být 30 voltů nebo méně. Je-li napětí vyšší než 30 voltů, nefungují na vozidle a kontaktní Eaton® na 1-800-826-HELP (4357).
9. Otočte klíčkem zapalování vypnout a pokračovat opravit nebo krok řešení potíží.
Poznámka: Napětí klesne na nulu, když je klíč off.
High-Voltage Service Power-Up Postup
1. Nainstalovat všechny konektory s vysokým napětím do jejich uzamčených poloh.
2. Jste-li osoba, která pracuje na vozidle, odebrat uzamčení držáku a značku.
3. Přeinstalovat uzamčení konzoly přes hlavní vypínač.
4. Vytáhněte hlavní vypínač a dejte set vozidel pro 2 minut.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid komponent a konektorů Umístění ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid komponent a konektorů Umístění MY09 Systems” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”KROK 1. Zkontrolujte, zda je stav aktivní nebo neaktivní chybových kódů a provést elektrické pretestu” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Přezkoumat a postupujte varování & Upozornění.
- Načíst aktivní chybové kódy a FMI pomocí ServiceRanger pomocí 9cestného diagnostického konektoru nebo ručně.
- Proveďte elektrické pretestu:
- -Li zjištěny žádné problémy během elektrotechnické předtestové, přejděte ke kroku 2.
- Pokud problém byl opraven v elektrotechnice předtestové, dokončení testu. Přejděte na krok 5.
[/fusion_content_box][fusion_content_box title=”KROK 2. Ověřit FMI dárek.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Načíst aktivní chybové kódy a FMI pomocí ServiceRanger pomocí 9cestného diagnostického konektoru nebo ručně.
- Key off.
Nebezpečí: Vidět High-Voltage Service vypnutí a zapnutí napájení Postupy. Postupujte podle pokynů, aby se zabránilo šoku, hořet nebo smrt neoprávněně manipulováno vysokého napětí. - Které FMIS jsou přítomny?
- pokud FMI 1 je uvedena, vyměnit střídače.
- Pokud se kód poruchy 114 IMF 3 nebo 4 je uvedena, přejděte ke kroku 3.
- Pokud se kód poruchy 114 není přítomen, dokončení testu. Přejděte na krok 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”KROK 3. Ověřit přítomnost napětí na střídači.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Odpojení střídače 56-Way Connector (MY08) 40-Way Connector (MY09).
- Připojte multimetr k Inverter 56 kolíkovðm 15 a Pin 1 (MY08) 40-Way Connector Pin 1 a Pin 6. (MY09).
- Místo multimetr, kde to může být viděn, když stál vedle kamionu.
- klíčem k.
- Pozorovat čtení multimetru napětí:
Poznámka: Gently flex the Inverter 56-Way Connector Harness near the connector while monitoring the voltage reading.- Pokud je napětí 11-13 voltů (na 12V systému) nebo 23- 25 voltů (na napětí 24 V systému), vyměnit střídače, přejděte ke kroku 5.
- Pokud napětí je větší než 16 voltů (na 12V systému) nebo 32 voltů (na napětí 24 V systému), opravovat systém dobíjení 12V vozidla. Podívejte se do OEM pro postup opravy.
- Pokud je napětí mimo rozsah, přejděte ke kroku 4.
[/fusion_content_box][fusion_content_box title=”KROK 4. Ověřovat návaznost spojů mezi HCM svazku a obraceče.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Odpojte záporný kabel baterie.
- Disconnect the HCM System Harness 38- way connector.
- Změřte odpor z následujících možností:
- Měnič 56-Way Connector Pin 15 to HCM 38- Way Connector Pin 2 (MY08). Inverter 40-Way Connector Pin 1 to HCM 38-Way Connector Pin 2 (MY09).
- Měnič 56-Way Connector Pin 1 do země (MY08) Inverter 40-Way Connector Pin 6 do země (MY09).
- Pokud odpor Pin 15 Pin 2 (MY08) nebo Pin 1 Pin 2 (MY09) je 0 na 0.3 ohmů a odpor Pin 1 do země je 0 na 0.3 ohmů, vyměnit hybridní řídicí modul (HCM). Přejděte na krok 5.
- Pokud je odpor mimo rozsah, Opravit přerušení napájení nebo Ground Harness, přejděte ke kroku 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”KROK 5. ověřte opravu.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Přečtěte si více” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Zapojte všechny konektory a záporný kabel baterie.
- klíčem k.
- jasné kódy, vidět Jasné Neaktivní Závady.
- Projeďte vozidlo a pokusit se obnovit kód.
- Zkontrolujte, zda kódy, vidět Zobrazit aktivní a neaktivní Chyby.
- Pokud žádné kódy, dokončení testu.
- Pokud chybový kód 114 objeví se, najít chybu v testování, přejděte ke kroku 1.
- Je-li kód jiný než 114 objeví se, vidět Porucha číselníku Rejstřík.