[fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Patahan Kode 8 – Kehilangan Switched Ignition Daya (HCM)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kesalahan kode untuk Eaton Hybrid Drive Sistem model (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P dan EH-6E706B-UPG. Hybrid Control Module (HCM) dipasang untuk transmisi dan berisi semua perangkat lunak untuk mengontrol kedua elektronika daya hybrid serta operasi transmisi. Kekuatan HCM pengapian adalah menyatu, tunggal pakan 12-volt yang berjalan melalui HCM 38-Way Kendaraan Connector.
kesalahan Kode 8 – Kehilangan Switched Ignition Daya (HCM) Deteksi
Prasyarat berikut harus dipenuhi sebelum sistem mendeteksi kesalahan:
- Output kecepatan Shaft harus lebih besar dari 0 RPM.
Kondisi Set Patahan Kode Aktif
Kondisi Set Patahan Kode:
• IMF 4 mengatur kapan HCM kehilangan daya pengapian selama operasi untuk 2 detik atau lebih besar.
Fallback Ketika Patahan Kode 8 diatur kondisi berikut terjadi:
- Amber “Periksa Hybrid” menyala terang.
- Kesalahan disimpan di Control Hybrid Modul (HCM) ingatan.
- Red “Service” menyala terang dan “F” berkedip di layar gigi, jika kesalahan terjadi sebelum power up.
- Kesalahan disimpan di Unit Transmisi Electronic Control (TECU) memori karena kurangnya komunikasi dengan HCM.
- Jika kesalahan terjadi saat kendaraan bergerak, transmisi tetap di tempat dan kopling terbuka ketika kendaraan datang ke menganggur. kopling menutup dan kendaraan akan beroperasi pada 1 dan sebaliknya dari berhenti.
- Jika kesalahan ini terjadi pada power up, kendaraan tidak engkol.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kondisi Set Patahan Kode Aktif
Hanya kesalahan yang tidak aktif bisa dibersihkan dari Unit Transmission Control Electronic (TECU) atau sejarah HCM menggunakan ServiceRanger. The TECU otomatis membersihkan kesalahan dari sejarah setelah 200 jam dan HCM otomatis membersihkan kesalahan dari sejarah setelah kesalahan telah aktif untuk 200 jam.
Kode kesalahan ini dapat disebabkan oleh salah satu dari berikut:
- IMF 4
- Pengapian Power Supply ke HCM
- HCM
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
kesalahan Kode 8 – Kehilangan Switched Ignition Daya (HCM) Uji
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Identifikasi komponen:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”2_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Depan Harness View” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Depan Harness View
(HCM – Kendaraan Antarmuka Connector)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14063|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Sensor temperatur ” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Typical-Relay-Switch.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Khas Relay Beralih
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
CATATAN: Mengacu kepada Eaton Hybrid Komponen dan Connector Lokasi untuk Connector Lokasi di MY08 Sistem
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
CATATAN: Mengacu kepada Eaton Hybrid Komponen dan Connector Lokasi untuk Connector Lokasi di MY09 Sistem.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14062|600″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”relay pengapian Eaton Fuller” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-ignition-relays-600×526.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”peringatan & Perhatian” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Bahaya: Bahaya menunjukkan Anda akan terluka parah atau terbunuh jika tidak mengikuti prosedur yang ditunjukkan.
Peringatan: Peringatan menunjukkan bahaya langsung, yang dapat mengakibatkan cedera pribadi yang parah jika Anda tidak mengikuti prosedur yang ditunjukkan.
Peringatan: Perhatian menunjukkan kendaraan atau kerusakan properti bisa terjadi jika Anda tidak mengikuti prosedur yang ditunjukkan.
Catatan: Catatan menunjukkan rincian tambahan yang akan membantu dalam diagnosis atau perbaikan komponen / sistem.
Ikuti prosedur yang ditetapkan dalam urutan yang ditunjukkan untuk menghindari cedera:
1. Jika kerucut tegangan tinggi sekitar kendaraan dan lockout dipasang di PEC, satu-satunya orang yang harus diperbolehkan untuk memulai kendaraan adalah orang yang menandatangani tag lockout.
2. Sebelum bekerja pada kendaraan atau meninggalkan taksi sementara mesin sedang berjalan, Anda harus menempatkan tuas pergeseran “N” set rem parkir, dan memblokir roda.
3. Untuk alasan keselamatan, selalu terlibat rem layanan sebelum memilih posisi gigi dari “N.”
4. Sebelum memulai kendaraan selalu duduk di kursi pengemudi, pilih “N” pada kontrol pergeseran, dan mengatur rem tangan.
5. Dalam kendaraan dengan ePTO, mesin dan / atau
Motor / Generator dapat mulai di modus ePTO. Tidak pernah melakukan perawatan atau bekerja pada kendaraan, Dalam modus ini.
6. 12-Volt Baterai positif (+) dan negatif (-) harus diputuskan sebelum pengelasan pada setiap Hybrid dilengkapi kendaraan.
Peringatan: Ikuti prosedur yang ditetapkan dalam urutan yang ditunjukkan untuk menghindari kerusakan peralatan atau kerusakan.
Peringatan: Jangan melepaskan rem parkir atau mencoba untuk memilih gigi sampai tekanan udara pada tingkat yang benar.
Peringatan: Untuk menghindari kerusakan transmisi selama penarik tempat tuas shift di “N” dan mengangkat roda penggerak dari tanah atau memutuskan driveline.
Peringatan Tegangan Tinggi & Perhatian
- Gunakan CO2 atau Dry Chemical Fire Extinguishers.
- Tegangan tinggi kabel ditutupi isolasi oranye atau tubing berbelit-belit dan ditandai dengan label peringatan pada konektor.
- Semua Eaton® Hybrid Diesel / kendaraan listrik akan ditandai ‘Hybrid’ di luar kendaraan, bersama dengan label pergeseran di dasbor.
- Mengacu pada OEM untuk lokasi tertentu dari chassis mount komponen hybrid.
- JANGAN potong kabel tegangan tinggi orange.
- TIDAK potong atau membuka PEC.
- TIDAK potong atau membuka Converter DC / DC.
- TIDAK potong atau membuka Inverter.
Sebuah zona penyangga harus diatur dan tegangan tinggi terisolasi sarung tangan karet (kelas 0 dengan pelindung kulit) diperlukan sebelum bekerja di tegangan tinggi. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Sarung tangan karet-terisolasi yang harus dikenakan saat bekerja pada sistem tegangan tinggi adalah kelas 0 dengan pelindung kulit. Sarung tangan karet harus diuji sebelum SETIAP digunakan mengikuti prosedur sarung tangan karet isolasi pengujian ditemukan di “Diagnostik Alat / Jasa Publikasi” pada halaman 6. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Sebelum memeriksa atau bekerja pada setiap kabel tegangan tinggi atau komponen yang “Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur” pada halaman 4 harus diikuti. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
The Lockout dan tagout perangkat hanya harus dihapus oleh teknisi yang menempatkan perangkat Lockout dan tagout pada kendaraan. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Tegangan tinggi karet terisolasi sarung tangan (kelas 0 dengan pelindung kulit) harus dipakai saat bekerja pada setiap
kabel tegangan tinggi. The “High-Voltage Layanan Shutdown dan Power-Up Prosedur” pada halaman 4 harus diikuti sebelum menghapus setiap kabel tegangan tinggi. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Tegangan tinggi kabel dan kabel yang oranye dan mengandung label peringatan pada konektor. komponen tegangan tinggi ditandai dengan label. Tegangan tinggi karet terisolasi sarung tangan (kelas 0 dengan pelindung kulit) harus digunakan ketika bekerja pada salah satu komponen ini. Kegagalan untuk mengikuti instruksi ini dapat menyebabkan cedera pribadi yang parah atau kematian.
Prosedur Layanan Shutdown Tegangan Tinggi
1. Ikuti “Tegangan Tinggi Wilayah Kerja” Prosedur.
2. Menemukan merah PEC Service Switch di depan PEC dan mendorong mematikan.
3. Lepaskan Service Switch Tutup dan menginstal Bracket Lockout (J48506).
4. tag Kencangkan ke Lockout Bracket.
5. Pastikan PEC Service Switch tidak bisa bergerak dari posisi off.
6. Memungkinkan sistem untuk mengatur selama minimal 5 menit untuk melepaskan tegangan tinggi.
7. Hubungkan ServiceRanger dan melihat Data Monitor PID 116 disebut “Tegangan Tinggi Potensi Battery.” Gunakan SPN 520323 untuk koneksi J1939 “Battery Voltage RB” (Relay Box).
8. tegangan harus 30 volt atau kurang. Jika tegangan di atas 30 volt, tidak bekerja pada kendaraan dan menghubungi Eaton® di 1-800-826-HELP (4357).
9. Putar kunci kontak off dan melanjutkan untuk memperbaiki atau langkah pemecahan masalah.
Catatan: tegangan turun ke nol ketika kuncinya adalah off.
Tegangan Tinggi Jasa Power-Up Prosedur
1. Install semua konektor tegangan tinggi ke posisi mereka terkunci.
2. Jika Anda adalah orang yang bekerja pada kendaraan, menghapus Lockout Bracket dan tag.
3. Instal ulang Lockout Bracket atas Service Switch.
4. Tarik Jasa Beralih keluar dan membiarkan kendaraan ditetapkan untuk 2 menit.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Komponen dan Connector Lokasi ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Komponen dan Connector Lokasi MY09 Sistem” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 1. Periksa status kode kesalahan dan kontinuitas Motor / Generator Sensor Suhu sirkuit” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Tinjau dan ikuti peringatan & Perhatian.
- Ambil kode kesalahan aktif dan FMIS dengan ServiceRanger menggunakan 9-Way Diagnostik Connector.
- off kunci.
- Lepaskan Sensor Suhu Connector di Motor / Generator.
Bahaya: Lihat Tegangan Tinggi Jasa Shutdown dan Power-Up Prosedur. Ikuti prosedur untuk menghindari kejutan, membakar atau kematian dari tidak benar ditangani tegangan tinggi. - 5. Mengukur resistensi di Motor / Generator 2-Way Sensor Suhu Connector dari Pin A ke Pin B(MY08)/ Pin 1 Pin 2(MY09):
- Jika resistance adalah 0.8K ohm untuk 301.7K ohm, pergi ke Langkah 2.
- Jika resistance berada di luar jangkauan, mengganti motor / Generator, kemudian pergi ke Langkah 3.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 2. Verifikasi kelangsungan nverter dan motor / Generator Sensor Suhu sirkuit.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci
- Lepaskan Inverter 56-Way Connector.
- 3. Hubungkan kembali Motor / Generator 2-Way Sensor Suhu Connector.
- Mengukur resistensi di berikut:
-
- Inverter 56-Way Connector Pin 50 Pin 38(MY08) / 40-Cara Connector Pin 37 Pin 36, inverter(MY09.
- Inverter 56-Way Connector Pin 50 ke tanah (MY08) / 40-Cara Connector Pin 37 ke tanah (MY09).
Catatan: Lembut melenturkan Inverter 56-Way Harness dekat Connector sementara memantau nilai-nilai resistensi.
- Jika resistance adalah 0.8K-301.7K ohm antara Pin 50 dan Pin 38 (37 & 37) dan perlawanan antara Pin 50 (37) dan tanah adalah 10K ohm atau lebih besar, mengganti Inverter, kemudian pergi ke Langkah 3.
- Jika resistance berada di luar jangkauan, memperbaiki terbuka atau pendek ke tanah di harness antara Connector Inverter dan Motor / Generator 2-Way Connector, kemudian pergi ke Langkah 3.
-
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”LANGKAH 3. Verifikasi perbaikan.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Baca lebih lajut” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- off kunci.
- Sambungkan kembali semua konektor dan kabel baterai negatif.
- tombol pada.
- kode jelas, melihat “Kesalahan Kode Retrieval dan Kliring” pada halaman 13.
- Drive kendaraan dan berusaha untuk me-reset kode.
- Periksa kode, melihat “Lihat Aktif dan Tidak Aktif Kesalahan” pada halaman 13.
- Jika tidak ada kode, tes selesai.
- Jika Kode Kesalahan 2 muncul, menemukan kesalahan dalam pengujian, pergi ke Langkah 1.
- Jika kode selain 2 muncul, Lihat Kesalahan Daftar Kode Indeks.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]