Eaton Fuller Hybrid Feilkode 6 – No HCM Operation

Feilkode for Eaton Hybrid Drive Systems modeller (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P og EH-6E706B-UPG. Hybrid kontrollmodul (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

Feilkode 6 – No HCM Operation Detection

Følgende forutsetninger må være oppfylt før systemet oppdager feilen:

  • HCM tennspenning er større enn 7 volt og mindre enn 16 volt.

Forhold som ligger Feilkode Aktiv

Forhold som ligger feil:

  • IMF 12 is set at key on if the HCM detects an internal failure.
  • IMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Når Feilkode 6 er satt følgende betingelser inntreffer:
• Amber “Sjekk Hybrid” tennes.
• If the fault occurs at power up the vehicle may not crank.

Forhold som ligger Feilkode Inaktiv

Bare Inaktive feil kan fjernes fra Transmission Electronic Control Unit (TECU) eller HCM historie ved hjelp ServiceRanger. Den TECU sletter automatisk feil fra historien etter 200 timer. HCM fjerner feilene fra historien etter at feilen har vært inaktiv for automatisk 200 timer.

Denne feilkoden kan være forårsaket av en hvilken som helst av de følgende:

  • IMF 12, 14
    • HCM

Feilkode 6 – No HCM Operation Test

Noen senderdel du må vi ha det! Samme dag shipping tilgjengelig, verdensomspennende.

Trenger gratis støtte fra en av våre eksperter?

RING NÅ
SEND OSS EN E-POST