Eaton Fuller Hybrid Fault Code 6 – No HCM Operation

Storing code voor Eaton Hybrid Drive Systems modellen (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-E / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P en EH-6E706B-UPG. De Hybrid Control Module (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

Fout code 6 – No HCM Operation Detection

De volgende randvoorwaarden moet worden voldaan voordat het systeem de fout detecteert:

  • HCM ontsteekspanning groter is dan 7 volt en minder dan 16 volt.

Voorwaarden voor Set Fault Code Active

Voorwaarden voor Set Fault:

  • IMF 12 is set at key on if the HCM detects an internal failure.
  • IMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Terugval Als Fault Code 6 ingesteld gebeurt het volgende:
• Amber “Controleer Hybrid” gaat branden.
• If the fault occurs at power up the vehicle may not crank.

Voorwaarden voor Set Fault Code Inactieve

Alleen Inactieve fouten kunnen worden gewist uit de Unit Transmission Electronic Control (TECU) of HCM geschiedenis met behulp ServiceRanger. De TECU verdwijnt automatisch de fouten uit de geschiedenis na 200 uur. De HCM verdwijnt automatisch de fouten uit de geschiedenis na de storing actief is geweest voor 200 uur.

Deze fout code kan worden veroorzaakt door een van de volgende:

  • IMF 12, 14
    • HCM

Fout code 6 – No HCM Operation Test