Eaton Fuller Hybrid Patahan Kode 6 – No HCM Operation

Kesalahan kode untuk Eaton Hybrid Drive Sistem model (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P dan EH-6E706B-UPG. Hybrid Control Module (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

kesalahan Kode 6 – No HCM Operation Detection

Prasyarat berikut harus dipenuhi sebelum sistem mendeteksi kesalahan:

  • HCM tegangan pengapian lebih besar dari 7 volt dan kurang dari 16 volt.

Kondisi Set Patahan Kode Aktif

Kondisi Set Sesar:

  • IMF 12 is set at key on if the HCM detects an internal failure.
  • IMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Ketika Patahan Kode 6 diatur kondisi berikut terjadi:
• Amber “Periksa Hybrid” menyala terang.
• If the fault occurs at power up the vehicle may not crank.

Kondisi Set Patahan Kode Aktif

Hanya kesalahan yang tidak aktif bisa dibersihkan dari Unit Transmission Control Electronic (TECU) atau sejarah HCM menggunakan ServiceRanger. The TECU otomatis membersihkan kesalahan dari sejarah setelah 200 jam. HCM otomatis membersihkan kesalahan dari sejarah setelah kesalahan telah aktif untuk 200 jam.

Kode kesalahan ini dapat disebabkan oleh salah satu dari berikut:

  • IMF 12, 14
    • HCM

kesalahan Kode 6 – No HCM Operation Test