Hybrid Eaton Fuller Gudbinta Babaca Code 116 – Babaca danab Relays Sare – (nidaamyada MY09)

Khalad code for Hybrid Eaton daydo Systems Drive (MY09) Cuneyso-8E406A-U / P, Cuneyso-8E406A-UP, Cuneyso-8E406A-UPG, Cuneyso-8E406A-CD, Cuneyso-8E406A-CDG, Cuneyso-8E406A-guud, Cuneyso-8E406A-T, Cuneyso-6E706B-CD, Cuneyso-6E706B-P iyo aad cuneyso-6E706B-UPG. Read hoose si aad u bartaan sida si ay u tijaabiso, nadiifiso iyo hagaajin qalad code qalad aad Freightliner, Mack, Peterbilt, Kenworth, Volvo, International, iyo gaari xamuul culus-waajib iyo qalabka. The Relays High-danab ku yaalaan gudaha Power ah
Electronics Carrier (PEC) ee unit Relay Box. There is one Pre-Charge Relay on the positive side, an additional relay on the positive, and on the negative for a total of three relays. Relays Kuwani caadi ahaan u furan yihiin marka nidaamka off waa. Relays waxaa gacanta ku dhex Inverter ah.

khalad Code 116 – Danab High Relays Babaca Ogaanshaha

The shuruud soo socda waa in la buuxiyaa ka hor inta nidaamka ogaadaa gardarrada:

  • danab suuroggalaan Inverter waa ka weyn yahay 7 volts iyo ka yar 16 volts.

Note: Marka dhib code ah Wax qabad la'aan tixraac ah Product Baarista Mode (PDM)

Xaaladaha in Calan Babaca Code Active

  • IMF 3 ayaa lagu wadaa markii gaaban ah si ay 12 volts la ogaado dhinaca gacanta ku Relay a high-voltage ah.
  • IMF 4 ayaa lagu wadaa markii gaaban ah in dhulka la ogaado dhinaca gacanta ku Relay a high-voltage ah.
  • IMF 5 iyo FMI 10 ayaa lagu wadaa markii circuit furan la ogaado dhinaca gacanta ku Relay a high-voltage ah.
  • IMF 7 iyo FMI 14 ayaa lagu wadaa markii Relay ugu weyn ee xun ku yahay iyo hoos u dhac inverter danab capacitor uu ka yar yahay 10-volts / 5 ilbiriqsi markii danab capacitor bilowga ahaa ka weyn tahay 200 volts.

Uugu Marka Babaca Code 116 ayaa lagu wadaa shuruudaha soo socda dhici:

  • Amber "Check Hybrid" illuminates light.
  • Gaf waxa lagu kaydiyaa Control Module Hybrid (Gudiga sare) xusuusta.
  • nidaamka hybrid wuxuu noqon doonaa offline.
  • Transmission defaults start gear to 1st in diesel-only mode.

Xaaladaha in Calan Babaca Code qabad la'aan

Kaliya unu firfircoonayn la nadiifiyay kartaa taariikhda TECU ama HCM isticmaalaya ServiceRanger. TECU ayaa si toos ah oo ansixiyay unu ka dib markii taariikhda 200 saacadood. Gudiga ayaa si toos ah oo ansixiyay Gaf taariikhda ka dib qalad in uu ahaa qabad la'aan 200 saacadood.

code qalad Tani waxaa keeni kara wax ka mid ah kuwan soo socda:

  • IMF 3, 4, 5, 7, 10, 14
    • Danab silig celinta ka DC / DC Converter in HCM
  • IMF 4
    • Relay Box
    • tiiro Switch
    • Inverter
    • Vehicle la habeeyo Fiilooyinka dhexeeya Inverter iyo PEC ah
    • Main High-danab Service Fiyuus Suurka ama ka maqan
    • DC High-danab Cable Interlock
    • PEC Switch Service Button Red

khalad Code 116 – Danab High Relays Babaca Test

Aqoonsiga Qeybta:

Duetsch 40-way mating connector view Inverter low-voltage connector

Duetsch 40-jidka isku xira view weheshiga
(Inverter isku xira low-danab)

Mating connector view Deutsch 19-way

Weheshiga view isku xira
(Deutsch 19-jidka isku xira)

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY09.

Inverter to PEC MY09 Systems

Qof kasta oo gudbinta qayb aad u baahan tahay aynu u leeyihiin! maalin isku mid ah maraakiibta la heli karo, dunida oo dhan.