Hybrid Eaton Fuller Gudbinta Babaca Code 118 – Darran High danab Relay Control Circuit Babaca

Khalad code for Hybrid Eaton daydo Systems Drive (MY09) Cuneyso-8E406A-U / P, Cuneyso-8E406A-UP, Cuneyso-8E406A-UPG, Cuneyso-8E406A-CD, Cuneyso-8E406A-CDG, Cuneyso-8E406A-guud, Cuneyso-8E406A-T, Cuneyso-6E706B-CD, Cuneyso-6E706B-P iyo aad cuneyso-6E706B-UPG. Read hoose si aad u bartaan sida si ay u tijaabiso, nadiifiso iyo hagaajin qalad code qalad aad Freightliner, Mack, Peterbilt, Kenworth, Volvo, International, iyo gaari xamuul culus-waajib iyo qalabka. The Relays a high-voltage kaabayaal, oo ku yaalla Electric Power ka Carrier (PEC), waxaa gacanta ku Control Module ku Hybrid (Gudiga sare). At muhiim ah oo ku saabsan, baalo korontada waxaa bixisey ka Box Relay u Relays a high-voltage kaabayaal. Marka xulashada ePTO la xushay on Control ku Riix badhanka Shift, Gudiga sare ee energizes wareeggeedii gacanta ee Relays xun ugu weyn ee togan iyo ugu weyn. Awoodda markaas socodka iyada oo Relays a high-voltage kaabayaal u Converter DC / DC.

khalad Code 118 – Darran High danab Control Relay Circuit Babaca Ogaanshaha

The shuruud soo socda waa in la buuxiyaa ka hor inta nidaamka ogaadaa gardarrada:

  • Control Module Hybrid (Gudiga sare) danab suuroggalaan waa ka weyn yahay 7 volts iyo ka yar 16 volts.

Note: Marka dhib code ah Wax qabad la'aan tixraac ah Product Baarista Mode (PDM)

Xaaladaha in Calan Babaca Code Active

  • IMF 3 is set when the HCM detects a short to battery in the coil circuit of the auxiliary high-voltage relay.
  • IMF 4 ayaa lagu wadaa markii Gudiga sare ee ogaadaa gaaban dhulka wareegi gariiradda ee Relay-danab sare ee kaabayaal ah.
  • IMF 5 ayaa lagu wadaa markii Gudiga sare ee ogaadaa furan wareegi gariiradda ee Relay-danab sare ee kaabayaal ah.

Uugu Marka Babaca Code 118 ayaa lagu wadaa shuruudaha soo socda dhici:

  • Amber "Check Hybrid" illuminates light.
  • Gaf waxa lagu kaydiyaa Control Module Hybrid (Gudiga sare) xusuusta.
  • The DC / DC Converter ma shaqeeyaan, sababtoo ah HCM de-energizes circuit Relay-danab sare ee kaabayaal ah.

Xaaladaha in Calan Babaca Code qabad la'aan

Kaliya unu qabad la'aan la nadiifiyay karaa Unit Gudbinta Electronic Control ah (TECU) ama taariikhda HCM isticmaalaya ServiceRanger. TECU ayaa si toos ah oo ansixiyay unu ka dib markii taariikhda 200 saacadood iyo HCM si toos ah oo ansixiyay unu ka soo taariikhda ka dib qalad uu Wax qabad la'aan, waayo, 200 saacadood.

code qalad Tani waxaa keeni kara wax ka mid ah kuwan soo socda:

  • IMF 3, 4, 5
    • OEM taararka ka HCM si PEC
    • cable DC / DC loop a high-voltage
    • DC / DC Converter
    • Darran Power Generator (APG) cable a high-voltage loop (haddii aan qalabaysnayn)
    • APG Converter (haddii aan qalabaysnayn)
    • Relay a high-voltage darran (gudaha PEC)

khalad Code 118 – Darran High danab Relay Control Circuit Babaca Test

Aqoonsiga Qeybta:

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY09.

HCM PEC DC DC APG Connectors Eaton Fuller transmission

Haddii aan gaari ku qalabeysan yahay APG, cap interlock HV leh loop waa in lagu rakibo haddii aan baabuurka ku qalabeysan yahay a DC / DC, A cap HV Interlock la loop waa in la rakibo.