[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Transmission Felkod 90 – KAN BCU 2 Meddelande (HCM)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Felkod för Eaton Hybrid Drive Systems modeller (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T och EH-6E606B-CD. Läs nedan för att lära hur man testar, rensa och fixa felet kodfel för Freightliner, Mack, Peterbilt, Kenworth, Volvo, Internationell, och tunga lastbilar och utrustning. Hybrid Control Module (HCM) kommunicera med omriktaren kommunicerar med Unit Batterikontroll (BCU) beläget i Power Electronics Carrier (PEC) och HCM på Controller Area Network (KAN) höghastighets proprietary datalänk. Datalänken är en tvåtråds partvinnad med två 120 ohm motstånd som finns i länken.

felkod 90 – KAN BCU 2 Meddelande (HCM) Upptäckt

Följande förutsättningar måste vara uppfyllda innan systemet upptäcker felet:

  • HCM tändspänningen är större än 7 volt och mindre än 16 volt.
  • HCM CAN datalänk fel är inaktiv.

Notera: När du felsöker en inaktiv kod hänvisar till Produkt Diagnostic läge (PDM)

Förhållanden som Set Fault Code Active

  • IMF 9 sätts när HCM inte har fått en BCU 2 meddelande till 30 meddelandecykler i följd.

Fallback När felkoder 90 är satt följande situationer uppstår:

  • Amber ”Check hybrid” tänds.
  • Fel lagras in Hybrid Control Module (HCM) minne.
  • Elmotor / generator Assist och Regeneration är inaktiverade; dock, högspänningsreläer förblir driven.
  • HCM fortsätter att styra hybridfordon i en diesel skyddat läge.
  • Transmission standard börjar redskap till

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Förhållanden som Set Fault Code inaktiv

Endast Inaktiva fel kan tas bort från enheten Transmission Electronic Control (TECU) eller HCM historia med användning ServiceRanger. Den TECU försvinner automatiskt fel från historien efter 200 timmar och HCM stänger automatiskt fel från historien efter det att felet har varit inaktiv under 200 timmar.

Denna felkod kan orsakas av något av följande:

  • FMI9
    • inverter
    • PEC
    • CAN datalänk från PEC till omriktaren

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

felkod 90 – KAN BCU 2 Meddelande (HCM) Testa

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

komponent~~POS=TRUNC:

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=yeshundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”10%” padding_bottom=”” padding_left=”10%”][fusion_builder_row][fusion_builder_column type=”1_3layout=”1_3spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14061|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM – Hybrid System Interface Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness Framifrån
(HCM – Hybrid System Interface Connector)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3layout=”1_3spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14474|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Delphi 56-Way Mating Connector View för Eaton Fuller överföring” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-56-Way-Mating-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Delphi 56-Way Mating Connector View

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3layout=”1_3spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”PEC – Low Voltage Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

PEC – Low Voltage Connector

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTERA: Referera till Eaton Hybrid Component och Connector Plats för Connector Platser i MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14502|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Fuller transmissions HCM inverter PEC Kontaktdon” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-Inverter-PEC-Connector.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”varningar & försiktighetsåtgärder” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Fara: Fara visar att du kommer att vara allvarligt skadas eller dödas om inte följer den angivna förfarandet.
Varning: Varning indikerar en omedelbar fara, vilket kan leda till allvarliga personskador om du inte följer den angivna förfarandet.
Varning: Försiktighet indikerar fordon eller egendomsskador kan uppstå om du inte följer den angivna förfarandet.

Notera: Anmärkning indikerar ytterligare detaljer som kommer att bistå vid diagnos eller reparation av en komponent / system.

Följ de angivna procedurerna i den angivna för att undvika personskador:

1. Om högspännings kottar är runt fordonet och lockout är installerad på PEC, den enda person som bör tillåtas att starta fordonet är den person som undertecknat lockout tag.
2. Innan du arbetar på ett fordon eller lämna hytten medan motorn är igång, ska du placera växelspaken i ”N” dra åt parkeringsbromsen, och blockera hjulen.
3. Av säkerhetsskäl, alltid engagera färdbromsarna innan du väljer växellägen från ”N.”
4. Innan du startar ett fordon alltid att sitta i förarsätet, välj ”N” på omställningsstyr, och dra åt parkeringsbromsar.
5. I bilar med ePTO, motorn och / eller
Motorn / generatorn kan börja i ePTO-läge. Utför aldrig något underhåll eller arbete på fordon, i det här läget.
6. 12-Volt Battery positiva (+) och negativ (-) måste kopplas bort innan någon svetsning på någon Hybrid utrustat fordon.

Varning: Följ de angivna procedurerna i den angivna för att undvika utrustning fel eller skador.
Varning: Släpp inte parkeringsbromsen och försök att välja en växel tills lufttrycket är på rätt nivå.
Varning: För att undvika skador på växellådan under bogsering plats växelspaken i ”N” och lyfta drivhjulen från marken eller koppla drivlinan.

Högspännings Varningar & försiktighetsåtgärder

  • Använd CO2 eller pulver Brandsläckare.
  • ledningar högspännings är täckt i orange isolering eller veckad slang och är markerade med varningsetiketter på kontaktdonen.
  • Alla Eaton® Hybrid diesel / Elfordon kommer att märkas ’Hybrid’ på utsidan av fordonet, tillsammans med skiftetiketten på instrumentbrädan.
  • Se OEM för specifik placering av chassimonterade hybridkomponenter.
  • Skär inte i det orangefärgade högspänningskablar.
  • Klipp inte in eller öppna PEC.
  • Klipp inte in eller öppna DC / DC-omvandlare.
  • Klipp inte in eller öppna omriktaren.

Ett buffertzonen måste inrättas och högspänningsisolerade gummihandskar (klass 0 med läderskydd) krävs innan arbetar på högspännings. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Gummiisolerade handskar som måste bäras under arbetet på högspänningssystemet är klass 0 med läderskydd. Gummihandskar bör testas före varje användning efter gummiisoleringshandskar testförfarande finns i ”Diagnostiska Verktyg / Service Publikationer” på sidan 6. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Innan inspektion eller arbetar på alla högspänningskablar eller komponenter ”High Voltage service avstängning och startordningen” på sidan 4 bör följas. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Lockouten och tagout enheter får endast tas bort av teknikern som placerade lockouten och tagout enheter på fordonet. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Högspänningsgummi isolerade handskar (klass 0 med läderskydd) måste användas vid arbete på någon
högspänningskablar. ”High-Voltage service avstängning och startordningen” på sidan 4 måste följas före avlägsnande av eventuella högspänningskablar. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Högspänningskablar och ledningar är orange och innehåller en varningsskylt vid kontakterna. Högspänningskomponenter är markerade med en etikett. Högspänningsgummi isolerade handskar (klass 0 med läderskydd) ska användas vid arbete på någon av dessa komponenter. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.

Högspännings service avstängningsprocedurer

Högspännings service avstängning och startordningen1. Följ ”High-Voltage Work Area” förfarande.
2. Leta reda på röda PEC Tjänst Slå på framsidan av PEC och skjut stänga.
3. Ta bort Service Switch Cover och installera Lockout Bracket (J48506).
4. Fäst tag till Lockout Bracket.
5. Se till att PEC Tjänst Switch kan inte flytta från avstängt läge.
6. Låt systemet för att ställa in minst 5 minuter för att ladda ur högspännings.
7. Anslut ServiceRanger och visa data monitor PID 116 kallad ”High-Voltage Battery potential.” Använd SPN 520323 för J1939 connection ”Battery Voltage RB” (reläbox).
8. Spänningen bör vara 30 volt eller mindre. Om spänningen ligger över 30 volt, fungerar inte på fordonet och kontakta Eaton® på 1-800-826-HELP (4357).
9. Vrid tändningslåset och fortsätt att reparera eller felsökningssteg.
Notera: Spänningen faller till noll när nyckeln är avstängd.

Högspännings service Startprocedur

1. Installera alla högspänningskontakter i sina låsta positioner.
2. Om du är den person som arbetar på fordonet, avlägsna Lockout Bracket och tagg.
3. Sätt tillbaka Lockout Bracket över service Switch.
4. Dra Service Switch och låt bilen set för 2 minuter.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Component och Connector Plats ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent- och kontakternas placering MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Component och Connector Plats MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent- och kontakternas placering MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STEP 1.Verify Aktiv och Inaktiv felkod status.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Hämta Aktiva felkoder och FMIS med ServiceRanger användning av 9-Way Diagnostic Connector eller manuellt.
  2. Utför Electrical förtest och Hybrid Electrical provkörning:
    • Om inga problem hittas under Hybrid Electrical provkörning, gå till steg 2.
    • Om problemet reparerades under Hybrid Electrical provkörning, gå till steg 4.

[/fusion_content_box][fusion_content_box title=STEG 2. Kontrollera CAN motstånd PEC 19-Way Connector.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
    Varning: Se Högspännings service avstängning och påslagning procedurer. Följ anvisningarna för att undvika chock, bränna eller död från hanteras felaktigt högspännings.
  2. Koppla PEC 19-Way Connector.
  3. Mäta motståndet mellan PEC 19-Way kontaktdon stift 1 och Pin 2:
    Notera: Se till att Volt / Ohm Meter är på rätt nivå (runt 200 ohm skala).

    • Om resistansen mellan Pin 1 och Pin 2 är mellan 50-70 ohm, ersätta Power Electronics Carrier (PEC), gå sedan till steg 4.
    • Om resistansen är utanför intervallet, gå till steg 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STEG 3. Kontrollera kontinuitet på PEC att Omriktaren kan Harness.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Bortkopplings Inverter 56-Way Connector.
  2. Mäta resistansen mellan:
    • Inverteraren 56-Way kontaktdon stift 28 och PEC 19- Way Connector Pin 2.
    • Inverteraren 56-Way kontaktdon stift 14 och PEC 19- Way Connector Pin 1.
      Notera: Se till att Volt / Ohm Meter är på rätt nivå (runt 200 ohm skala). Notera: flex försiktigt Inverter 56-Way Connector Harness nära kontakt under övervakning resistansvärdena.

      • Om resistansen mellan Pin 28 och Pin 2 är mellan 0-0,2 ohm, och motstånd mellan Pin 14 och Pin 1 är mellan 0-0,2 ohm, ersätta Inverter, gå sedan till steg 4.
      • Om resistansen är utanför intervallet, reparation kan Data Link Harness mellan Inverter och PEC, gå sedan till steg 4.

[/fusion_content_box][fusion_content_box title=STEG 4. verifiera reparation.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Key off.
  2. Anslut alla kontakter och den negativa batterikabeln.
  3. Key på.
  4. tydliga koder, se Tydliga Inaktiva fel.
  5. Kör fordonet och försöka återställa koden.
  6. Kontrollera om koder, se Visa aktiva och inaktiva fel.
    • Om inga koder, testet är klart.
    • Om felkoden 90 visas, hitta fel i test, gå till steg 1.
    • Om annan kod än 90 visas, se Felkod Index List.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]