[fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Κωδικός σφάλματος 24 – J1939 HCM μηνύματος (TECU)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Κωδικός σφάλματος για Eaton υβριδικά μοντέλα Συστήματα κίνησης (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-Ρ και EH-6E706B-UPG. Η μονάδα ηλεκτρονικού ελέγχου της μετάδοσης (TECU) επικοινωνεί με την υβριδική μονάδα ελέγχου (HCM) κατά τη διάρκεια της ζεύξης δεδομένων J1939 κατά τη λειτουργία του οχήματος για την ανταλλαγή ζήτησε εργαλεία και τις τρέχουσες πληροφορίες εργαλεία.
Κωδικός σφάλματος 24 – J1939 HCM μηνύματος (TECU) Ανίχνευση
Οι ακόλουθες προϋποθέσεις πρέπει να πληρούνται πριν από το σύστημα ανιχνεύει το σφάλμα:
- TECU τάση ανάφλεξης είναι μεγαλύτερη από 7 volts και λιγότερο από 16 βολτ.
- No J1939 data link fault currently Active in the TECU.
Προϋποθέσεις ορισμού σφάλμα κώδικα Active
- ΔΝΤ 9 ορίζεται όταν η TECU δεν λαμβάνει δεδομένα εκπομπής (όπως μια ζητήθηκε ταχυτήτων) Για 2 δευτερόλεπτα ή περισσότερο από το HCM, και εξακολουθεί να επικοινωνεί με άλλες μονάδες στη J1939.
Εναλλακτικό Όταν σφάλμα κώδικα 24 έχει οριστεί στις εξής περιπτώσεις:
- Κόκκινο «Υπηρεσία» φως ανάβει, και ένα «F» αναβοσβήνει στην οθόνη ταχυτήτων.
- Βλάβη αποθηκεύεται στη μνήμη TECU.
- Τρόπος λειτουργίας αλλαγές στη λειτουργία autoshift υποβάθμισης.
- Αν η βλάβη θέτει σε ισχύ μέχρι, the engine does not crank.
- Αν τα σύνολα σφάλμα κατά την οδήγηση, το όχημα παραμένει σε τρέχουσα ταχύτητα. Όταν το όχημα σταματά ο συμπλέκτης ανοίγει και παραμένει σε αυτή τη θέση.
- Amber “Check Hybrid” light may display on the dash due to an Active Κωδικός σφάλματος 48.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Προϋποθέσεις ορισμού σφάλμα κώδικα Ανενεργό
Μόνο Ανενεργό σφάλματα μπορεί να διαγραφεί από την ιστορία TECU ή HCM χρησιμοποιώντας ServiceRanger. Η TECU καθαρίζει αυτόματα τα σφάλματα από την ιστορία μετά 200 ώρες. Η HCM καθαρίζει αυτόματα ένα σφάλμα από την ιστορία, αφού έχει μείνει ανενεργός για 200 ώρες.
Αυτός ο κωδικός βλάβης μπορεί να προκληθεί από οποιοδήποτε από τα ακόλουθα:
- ΔΝΤ 9
- J1939 Data Link
- HCM
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Κωδικός σφάλματος 24 – J1939 HCM μηνύματος (TECU) Δοκιμή
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Σύστημα Component αναγνώρισης MY08:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14126|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Ιμάντες Πρόσοψη TECU – Όχημα Interface σύνδεσης” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Harness-Front-View-TECU.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Ιμάντες Πρόσοψη
TECU – Όχημα Interface σύνδεσης
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Harness Πρόσοψη (HCM – Όχημα Interface σύνδεσης)” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Ιμάντες Πρόσοψη
(HCM – Όχημα Interface σύνδεσης)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ΣΗΜΕΙΩΣΗ: Αναφέρομαι στο Eaton υβριδικά Component και σύνδεσης Τοποθεσία για Connector Τοποθεσίες σε MY08 Συστήματα
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ΣΗΜΕΙΩΣΗ: Αναφέρομαι στο Eaton υβριδικά Component και σύνδεσης Τοποθεσία για Connector Τοποθεσίες σε MY09 Συστήματα.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14163|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”υποδοχή Eaton Fuller TECU HCM” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-TECU-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”προειδοποιήσεις & Προφυλάξεις” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Κίνδυνος: Κίνδυνος σημαίνει πως θα τραυματιστεί σοβαρά ή σκοτώνονται, αν δεν ακολουθήσει την ενδεδειγμένη διαδικασία.
Προειδοποίηση: Προειδοποίηση υποδεικνύει άμεσο κίνδυνο, η οποία θα μπορούσε να οδηγήσει σε σοβαρό τραυματισμό, αν δεν ακολουθήσετε τη διαδικασία που αναφέρεται.
Προσοχή: Προσοχή υποδεικνύει όχημα ή υλικές ζημιές θα μπορούσε να συμβεί, αν δεν ακολουθήσετε τη διαδικασία που αναφέρεται.
Σημείωση: Σημείωση υποδεικνύει επιπλέον λεπτομέρεια που θα βοηθήσει στη διάγνωση ή την επισκευή ενός συστατικού / σύστημα.
Ακολουθήστε τις διαδικασίες που ορίζονται με την αναφερόμενη σειρά για να αποφύγετε τραυματισμούς:
1. Αν οι κώνοι υψηλής τάσης είναι γύρω από το όχημα και το lockout είναι εγκατεστημένο στον PEC, το μόνο πρόσωπο που θα πρέπει να έχουν τη δυνατότητα να ξεκινήσει το όχημα είναι το πρόσωπο που υπέγραψε την ετικέτα κλειδώματος.
2. Πριν από κάθε εργασία σε ένα όχημα ή εξέρχονται από την καμπίνα, ενώ ο κινητήρας είναι σε λειτουργία, θα πρέπει να τοποθετήσετε τον μοχλό αλλαγής ταχυτήτων στη «Ν» που το χειρόφρενο, και να μπλοκάρει τους τροχούς.
3. Για λόγους ασφαλείας, πάντα εμπλέκονται τα φρένα υπηρεσίας πριν από την επιλογή θέσεις ταχυτήτων από το «Ν»
4. Πριν ξεκινήσετε ένα όχημα πάντα να κάθονται στο κάθισμα του οδηγού, επιλέξτε «Ν», για τον έλεγχο μετατόπισης, και ρυθμίστε τα φρένα στάθμευσης.
5. Σε οχήματα με EPTO, ο κινητήρας / ή και
Motor / γεννήτρια μπορεί να ξεκινήσει σε λειτουργία EPTO. Ποτέ μην εκτελέσει οποιαδήποτε συντήρηση ή εργάζονται σε όχημα, ενώ σε αυτή την κατάσταση.
6. 12-Volt μπαταρίας θετική (+) και αρνητικά (-) πρέπει να αποσυνδεθεί πριν από οποιαδήποτε συγκόλληση σε οποιοδήποτε Hybrid εξοπλισμένο όχημα.
Προσοχή: Ακολουθήστε τις διαδικασίες που ορίζονται με την αναφερόμενη σειρά για να αποφευχθεί η δυσλειτουργία του εξοπλισμού ή τη ζημία.
Προσοχή: Μην αφήστε το χειρόφρενο ή να προσπαθήσει να επιλέξετε ταχύτητα έως ότου η πίεση του αέρα είναι στο σωστό επίπεδο.
Προσοχή: Για να αποφύγετε ζημιά στο κιβώτιο ταχυτήτων κατά τη διάρκεια της ρυμούλκησης θέση του μοχλού αλλαγής ταχυτήτων στο «Ν» και να άρει τους κινητήριους τροχούς από το έδαφος ή αποσυνδέστε το σύστημα μετάδοσης κίνησης.
Προειδοποιήσεις Υψηλής Τάσης & Προφυλάξεις
- Χρησιμοποιήστε CO2 ή ξηρές χημικές ουσίες πυροσβεστήρες.
- Η καλωδίωση υψηλής τάσης καλύπτεται με πορτοκαλί χρώμα μόνωση ή μπερδεμένη σωλήνωση και επισημαίνονται με προειδοποιητικές ετικέτες στα συνδετήρες.
- Όλα τα Eaton® Υβριδικό Diesel Ηλεκτρικά οχήματα / θα φέρει την ένδειξη «Hybrid’ στο εξωτερικό του οχήματος, μαζί με τη σήμανση στροφή στο ταμπλό.
- Ανατρέξτε στην ΚΑΕ για την συγκεκριμένη θέση του πλαισίου τοποθετούνται υβριδικών εξαρτημάτων.
- Μην κόβετε στα πορτοκαλί καλώδια υψηλής τάσης.
- Μην κόβετε σε ή να ανοίξετε την PEC.
- Μην κόβετε σε ή να ανοίξετε το μετατροπέα DC / DC.
- Μην κόβετε σε ή να ανοίξετε το μετατροπέα.
Μια ρυθμιστική ζώνη πρέπει να συσταθεί και υψηλής τάσης με μόνωση από καουτσούκ γάντια (τάξη 0 με δερμάτινα προστατευτικά) απαιτούνται προτού εργαστούν με υψηλής τάσης. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
Τα λαστιχένια μόνωση γάντια που πρέπει να φορεθεί, ενώ εργάζονται για το σύστημα υψηλής τάσης είναι κατηγορίας 0 με δερμάτινα προστατευτικά. Τα λαστιχένια γάντια θα πρέπει να ελέγχονται πριν από κάθε χρήση σύμφωνα με τη διαδικασία λαστιχένια μόνωση γάντια δοκιμές που βρέθηκαν στο «διαγνωστικά εργαλεία / Υπηρεσία Εκδόσεων» στη σελίδα 6. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
Πριν από την επιθεώρηση ή εργάζονται σε οποιοδήποτε καλώδια υψηλής τάσης ή συνιστώσες της «υψηλής τάσης Υπηρεσία Shutdown και Power-Up Διαδικασία» στη σελίδα 4 θα πρέπει να ακολουθηθεί. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
Οι συσκευές κλειδώματος και Tagout πρέπει να αφαιρεθεί μόνο από τον τεχνικό που τοποθετείται τις συσκευές κλειδώματος και Tagout στο όχημα. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
Υψηλής τάσεως λαστιχένια μονωτικά γάντια (τάξη 0 με δερμάτινα προστατευτικά) πρέπει να φοριούνται κατά την εργασία σε οποιαδήποτε
καλώδια υψηλής τάσης. Η «Shutdown Υψηλής Τάσης Υπηρεσία και Power-Up Διαδικασία» στη σελίδα 4 πρέπει να ακολουθούνται πριν από την αφαίρεση των τυχόν καλώδια υψηλής τάσης. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
καλώδια υψηλής τάσης και την καλωδίωση είναι πορτοκαλί και περιέχουν μια ετικέτα προειδοποίησης στις υποδοχές. Τα εξαρτήματα υψηλής τάσης σημειώνονται με ετικέτα. Υψηλής τάσεως λαστιχένια μονωτικά γάντια (τάξη 0 με δερμάτινα προστατευτικά) πρέπει να χρησιμοποιείται κατά την εργασία σε οποιοδήποτε από αυτά τα συστατικά. Εάν δεν ακολουθήσετε αυτές τις οδηγίες μπορεί να οδηγήσει σε σοβαρό τραυματισμό ή θάνατο.
Υψηλής Τάσης διαδικασίες τερματισμού των υπηρεσιών
1. Ακολουθήστε «υψηλής τάσης του χώρου εργασίας» διαδικασία.
2. Εντοπίστε το κόκκινο διακόπτη PEC Υπηρεσία στο μπροστινό μέρος της PEC και σπρώξτε απενεργοποιήσετε.
3. Αφαιρέστε το κάλυμμα του διακόπτη υπηρεσία και να εγκαταστήσετε το βραχίονα κλειδώματος (J48506).
4. Στερεώστε ετικέτα με το Lockout Στήριγμα.
5. Βεβαιωθείτε ότι ο διακόπτης PEC Υπηρεσία δεν μπορεί να μετακινηθεί από τη θέση off.
6. Αφήστε το σύστημα να θέσει ένα ελάχιστο 5 λεπτά να εκπληρώσει υψηλής τάσης.
7. Συνδέστε ServiceRanger και δείτε την οθόνη PID Δεδομένων 116 που ονομάζεται «Υψηλής Τάσης Δυναμικό μπαταρίας.» Χρήση SPN 520323 για τη σύνδεση J1939 «Τάση μπαταρίας RB» (ρελέ ασφαλείας).
8. Η τάση πρέπει να είναι 30 volts ή λιγότερο. Αν η τάση είναι πάνω από 30 βολτ, δεν λειτουργούν στο όχημα και να επικοινωνήσετε Eaton® σε 1-800-826-HELP (4357).
9. Γυρίστε το κλειδί ανάφλεξης μακριά και να προχωρήσει στην επισκευή ή βήμα αντιμετώπισης προβλημάτων.
Σημείωση: Η τάση πέφτει στο μηδέν όταν το κλειδί είναι εκτός λειτουργίας.
Υψηλής Τάσης Υπηρεσία Power-Up Διαδικασία
1. Εγκαταστήστε όλα τα βύσματα σύνδεσης υψηλής τάσης στην κλειδωμένη θέση τους.
2. Εάν είστε το πρόσωπο που εργάζεται επί του οχήματος, αφαιρέστε το Lockout βραχίονα και ετικέτα.
3. Τοποθετήστε ξανά το Lockout βραχίονα πάνω από το διακόπτη Υπηρεσία.
4. Τραβήξτε την Υπηρεσία Αλλαγή έξω και αφήστε το σύνολο του οχήματος για 2 λεπτά.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton υβριδικά Component και σύνδεσης Τοποθεσία ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton υβριδικά Component και σύνδεσης Τοποθεσία MY09 Συστήματα” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”ΒΗΜΑ 1. Ελέγξτε για Ενεργό ή Ανενεργό κατάσταση βλαβών και να εκτελέσει Ηλεκτρικές προμέτρησης.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Διαβάστε περισσότερα” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Ανάκτηση Active κωδικών βλάβης και FMIS με ServiceRanger χρησιμοποιώντας το 9-Way διαγνωστικός συνδετήρας.
- Εκτελέστε το Ηλεκτρική προμέτρησης.
- Αν δεν τα θέματα που βρέθηκαν κατά τη διάρκεια της Ηλεκτρική προμέτρησης, μεταβείτε στο Βήμα 2.
- Εάν το πρόβλημα επισκευάστηκε κατά τη διάρκεια της Ηλεκτρική προμέτρησης, μεταβείτε στο Βήμα 3.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”ΒΗΜΑ 2. Επιβεβαιώστε τη συνέχεια του οχήματος Harness.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Διαβάστε περισσότερα” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Βασικά off.
- Αποσυνδέστε το αρνητικό καλώδιο της μπαταρίας.
- Disconnect HCM Vehicle Harness 38- τρόπος σύνδεσης.
- Measure resistance between HCM Vehicle Harness 38- Τρόπος σύνδεσης Pin 2 και Pin 3:
Σημείωση: Βεβαιωθείτε ότι το Volt / Ohm μετρητής είναι στην κατάλληλη κλίμακα (γύρω 200 κλίμακα ohm).- Αν η αντίσταση μεταξύ των ακίδων 2 και Pin 3 είναι μεταξύ 50-70 Ω, αντικαταστήστε την υβριδική μονάδα ελέγχου (HCM), Στη συνέχεια μεταβείτε στο Βήμα 3.
- Εάν η αντίσταση είναι εκτός του εύρους, επισκευή J1939 δεδομένων καλωδίωσης σύνδεσης, Στη συνέχεια μεταβείτε στο Βήμα 3.
[/fusion_content_box][fusion_content_box title=”ΒΗΜΑ 3. Επιβεβαίωση επισκευής” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Βασικά off.
- Επανασυνδέστε όλες τις συνδέσεις και αρνητικό καλώδιο της μπαταρίας.
- Κλειδί για την.
- Σαφείς κώδικες, βλέπω Clear Ανενεργό Βλάβες.
- Οδηγήστε το όχημα και να προσπαθήσετε να επαναφέρετε τον κωδικό.
- Έλεγχος για κωδικούς, βλέπω Δείτε Ενεργό και Ανενεργό Βλάβες.
- Αν δεν κωδικοί, δοκιμή είναι πλήρης.
- Εάν το σφάλμα 24 εμφανίζεται, βρείτε λάθος στις δοκιμές, μεταβείτε στο Βήμα 1.
- Εάν ένας κωδικός, εκτός από 24 εμφανίζεται, βλέπω Σφάλμα Λίστα Κώδικα Δείκτης.