[fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller хибриден Грешка законик 22 – J1939 ABS Грешка порака (HCM)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Дефект код за Eaton хибридни модели диск системи (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-РДО, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P и EH-6E706B-UPG. J1939 е со голема брзина извртени пар 250K врската со податоци со еден 120 оми отпорник на секој крај на врската. На HCM е поврзан со J1939 линк податоци за во 38-Way конектори. Оваа врска се користи за пренос на информации до HCM како и комуникација или да примите податоци од други модули на мрежата како модул ABS.
Дефект законик 22 – J1939 ABS Грешка порака (HCM) детекција
Следните предуслови треба да се исполнат пред системот детектира грешка:
- HCM напонот за палењето е поголема од 7 волти и помалку од 16 волти.
- J1939 линк податоци комуникациска грешка не е активен.
Услови за поставување Грешка Код Active
- ММФ 9 е поставено кога HCM не ја добие ABS пораки и нема активни грешки J1939. Во режим на PDM (ММФ 2) оваа грешка е поставена ако 3 последователни пораки (EBC1) не се примени.
- ММФ 14 е поставено кога HCM добива Активни ABS сигнал (SPN563) out of range or the ABS “Fully Operational Signal” (SPN1243) не е присутна 1 вториот.
Резервен план Кога Дефект законик 22 е поставена да се јават следните услови:
- Килибарните "Провери Hybrid" светлина дисплеи.
- Грешка се чуваат во HCM меморија.
- Ако се појави грешка додека се движат, режим на работа оди во AutoShift само.
- Електричен мотор / генератор за помош и обнова се исклучени; сепак, релеи висок напон остане погон.
- Пренос стандардно почне брзина до 1.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Оваа грешка кодот може да биде предизвикана од било кое од следниве:
- ММФ 2, 9
- J1939 линк на податоци
- ABS Модул
- ММФ 14
- ABS Модул конфигуриран да комуницираат на J1708 или аналоген наместо J1939.
- ABS модул за известување активен грешка.
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Дефект законик 22 – J1939 ABS Грешка порака (HCM) тест
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
компонента за идентификација:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14061|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”никој” bordersize=”” bordercolor=”” borderradius=”” align=”центар” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”идентификација пренос компонента Eaton” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Предна Впрегнете Види
(HCM – Возило Интерфејс конектор)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ЗАБЕЛЕШКА: Се однесуваат на Eaton хибриден компоненти и конектори Локација Конектор за локации.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14159|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”никој” bordersize=”” bordercolor=”” borderradius=”” align=”центар” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”пренос Eaton ABS HCM конектор” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-transmission-ABS-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”Предупредувања & Предупредувања” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]опасност: Опасност покажува дека вие ќе биде сериозно повредени или убиени, ако не ги следат наведено постапка.
Предупредување: Предупредување укажува на непосредна опасност, што може да предизвика сериозни повреди ако не ги следат наведено постапка.
Внимание: ВНИМАНИЕ укажува на возилото или оштетување на имот може да се случи ако не ги следат наведено постапка.
Забелешка: Забелешка покажува дополнителни детали кои ќе помогнат во дијагнозата или поправка на компонента / систем.
Следат посебните постапки во означената цел да се избегнат повреди:
1. Ако шишарки на висок напон околу возилото и болест е инсталиран на ПЕК, единствената личност што треба да биде дозволено да се запали возилото е лицето кое го потпишаа болест таг.
2. Пред работат на возило или напуштање на кабината додека работи моторот, треба да се одржи на рачката на менувачот во "N" постави рачната сопирачка, и да го блокира тркалата.
3. Од безбедносни причини, секогаш се вклучат кочници пред изборот брзини од "Н"
4. Пред отпочнување на возилото секогаш се седи во седиштето на возачот, изберете "N" за контрола на промена, и го постави сопирачките на паркинг.
5. Во возилата со ePTO, на моторот и / или
Мотор / генератор може да почне во режим ePTO. Никогаш не се вршат какви било одржување или работат на возилото, додека во овој режим.
6. 12-Волт батерија позитивни (+) и негативни (-) мора да биде исклучен пред било заварување на било хибриден опремено возило.
Внимание: Следат посебните постапки во означената цел да се избегне опрема дефект или оштетување.
Внимание: Не ја отпуштите рачната сопирачка или да се обидете да изберете брзина додека воздушниот притисок е на правилно ниво.
Внимание: За да се избегне оштетување на пренос при влечење место рачката на менувачот во "N" и укинување на погонските тркала надвор од земјата и не исклучувајте го погонска група.
Висок напон Предупредувања & Предупредувања
- Користете CO2 или сув хемиски противпожарни апарати.
- жици на висок напон е покриена со портокал изолација или згрчена цевки и означени со предупредување етикети на конектори.
- Сите Eaton® хибриден дизел / Електрични возила ќе бидат означени со "Hybrid’ на надворешната страна на возилото, заедно со етикетата на промена на цртичка.
- Се однесуваат на OEM за одредена локација на шасијата монтирани хибридни компоненти.
- Не се намали во портокалова високонапонски кабли за.
- Не се намали или да се отвори во ПЕК.
- НЕ се сече или да се отвори на DC / DC конвертор.
- Не се намали или да се отвори во инверторски.
Заштитен појас мора да се постави и висок напон изолација гумени ракавици (класа 0 со кожа штитници) се потребни пред да работат на висок напон. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
гумени изолирани ракавици кои мора да се носат додека се работи на системот на висок напон се класа 0 со кожа штитници. гумени ракавици треба да се проверат пред секоја употреба следнава постапка гумени изолација ракавици тестирање се најде во "дијагностички алатки / услуга Публикации" на страница 6. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
Пред инспекција или работат на било високо-напонски кабли или компоненти на "висок напон служба исклучување и моќ-up постапка" на страница 4 треба да се следи. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
Уредите за болест и Tagout треба да се отстранат само со техничар кој поставени уредите болест и Tagout на возилото. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
Висок напон со изолација од гума ракавици (класа 0 со кожа штитници) мора да се носат кога се работи на било кој
кабли висок напон. "Услугата Исклучување висок напон и моќ-up постапка" на страница 4 мора да се следи пред отстранување на било високо-напонски кабли. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
Високонапонски кабли и жици се портокалови и да содржи предупредување етикета на конектори. компоненти висок напон се означени со етикета означени. Висок напон со изолација од гума ракавици (класа 0 со кожа штитници) мора да се користи кога се работи на било кој од овие компоненти. Непочитувањето на овие упатства може да резултира со сериозни повреди или смрт.
Висок напон услуги Исклучување процедури
1. Следи "висок напон работа област" постапка.
2. Лоцира црвено PEC услуги Вклучете го предниот дел на ПЕК и да се поттикнат да го исклучите.
3. Отстрани служба Switch Корица и да ја инсталирате на локаутот држач (J48506).
4. Прицврстете ознака на локаутот држач.
5. Префрли се обезбеди ПЕК сервис не може да се движи од надвор позиција.
6. Им овозможи на системот да се постави за минимум 5 минути за да се ослободи висок напон.
7. Поврзете ServiceRanger и да ја видите монитор PID на податоци 116 се нарекува "висок напон потенцијалот на батеријата." Употреба СФМ 520323 за J1939 врска "батеријата напон РБ" (реле кутија).
8. На напонот треба да биде 30 волти или помалку. Ако напонот е над 30 волти, не работат на возилото и контактирајте Eaton® на 1-800-826-HELP (4357).
9. Свртете го клучот во стартерот и продолжи да се поправи или чекор за смена на проблеми.
Забелешка: Напонот ќе падне на нула кога клучот е исклучен.
Висок напон служба моќ-up постапка
1. Ставете ги сите високо-напонски приклучоци во заклучена своите позиции.
2. Ако сте личност која работи на возилото, отстранување на локаутот конзола и ознака.
3. Инсталирај го на локаутот конзола во текот Switch сервисот.
4. Повлечете сервисот Switch надвор и нека сет возило за 2 минути.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton хибриден компоненти и конектори Локација ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton хибриден компоненти и конектори Локација MY09 системи” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”не-повторуваат” fade=”no” background_parallax=”никој” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”не-повторуваат” hover_type=”никој” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”лево” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”лево” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”ЧЕКОР 1. Провери за активен или неактивен статус вина кодот.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Прочитај повеќе” link_target=”” animation_type=”” animation_direction=”лево” animation_speed=”0.3″ animation_offset=””]
- Retrieve the Active fault codes and FMIs with ServiceRanger using the 9-Way Diagnostic Connector.
- Кои FMIs се присутни?
- Ако Грешка законик 22 ММФ 9 се наведени, Проблемот е со линк на податоци 'рбетот ABS модул или со J1939 линк податоци од ABS Модул за J1939 на. Се однесуваат на OEM за поправка процедури.
- Ако Грешка законик 22 ММФ 14 се наведени, problem is with the Data Link ABS Module being configured for J1708 instead of J1939 communication, и / или со ABS Модул себе. Се однесуваат на OEM за поправка процедури.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]