[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Гібрыд Трансмісія Код памылкі 113 – ток пераўтваральніка
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Код памылкі для Eaton гібрыдных мадэляў сістэмы прывадаў (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-У / Р, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-Т, EH-6E706B-CD, EH-6E706B-Р і EH-6E706B-УПГ. Read below to learn how to test, ачысціць і выправіць памылкі коды няспраўнасці для Freightliner, Mack, Peterbilt, Kenworth, Volvo, міжнародны, і цяжкія грузавікі і абсталяванне. Інвертар падключаецца да сілавой электронікі Carrier (PEC) праз высакавольтны кабель пастаяннага току, які падае 340 вольт ад батарэй. Падчас працы, Інвертар кантралюе выхадны ток рухавік / генератар.
код памылкі 113 – Inverter Current Detection
Наступныя папярэднія ўмовы павінны быць выкананы да таго, як сістэма выявіць памылку:
- Напружанне інвертар запальвання вышэй 7 вольт і менш 16 вольт.
Нататка: Пры ліквідацыі неактыўнага кода звярніцеся да Дыягнастычны рэжым прадукту (ДПМ)
Умовы Усталяваць Код памылкі Актыўны
- МВФ 6 усталёўваецца, калі ток інвертар IGBT больш 800 ўзмацняльнікі для 0.05 MS або кабель рухавіка кароткі.
- МВФ 14 усталёўваецца, калі крутоўны момант рухавіка наказаў роўны нулю, а ток паведамляе інвертарам.
Запасны Калі код няспраўнасці 113 is set the following conditions occur:
- Amber «Праверыць Гібрыдныя» святло гарыць.
- Памылка захоўваецца ў модулі кіравання гібрыдным (HCM) памяць.
- Інвертар адключае сістэму высокага напружання ад.
- НСМ працягвае кантраляваць гібрыднае транспартны сродак у рэжыме дызель-толькі.
- па змаўчанні перадачы пачаць перадачу на 1.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Умовы паказаны код няспраўнасці Inactive
Толькі Неактыўныя няспраўнасці могуць быць ачышчаны ад блока перадачы электроннага кіравання (TECU) або гісторыя HCM з выкарыстаннем ServiceRanger. TECU аўтаматычна выдаляе інфармацыю аб няспраўнасці з гісторыі пасля таго, як 200 гадзіны і HCM аўтаматычна выдаляе інфармацыю аб няспраўнасці з гісторыі пасля збою былі неактыўнымі 200 гадзін.
Гэты код няспраўнасці можа быць выкліканы любым з наступных:
- МВФ 2
- інвертар
- рухавік / генератар
- Кабелі высокага напружання пераменнага току
- МВФ 14
- рухавік / генератар
- Кабелі пераменнага току высокага напружання
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
код памылкі 113 – Інвертар току выпрабаванні
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ідэнтыфікацыя кампанентаў:
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”10%” padding_bottom=”” padding_left=”10%”][fusion_builder_row][fusion_builder_column type=”1_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”13902|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Пераменнага току высокага напружання Праводка Раз'ём Прагляд” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Harness-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Пераменнага току высокага напружання Праводка Раз'ём Прагляд
(Amphenol Раз'ём)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”13903|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Высакавольтны рухавік пераменнага току / Gen Раз'ём Amphenol Від раз'ём” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Motor-Gen-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
сістэма MY08 – Высакавольтны рухавік пераменнага току / Генератар Раз'ём Прагляд
(Amphenol Раз'ём)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_3″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14034|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Высакавольтны рухавік пераменнага току / Gen Раз'ём Прагляд” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Motor-Gen-Connector-View-MY09.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
сістэма MY09- Высакавольтны рухавік пераменнага току / Генератар Раз'ём Прагляд
(Amphenol Раз'ём)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
НАТАТКА: звярніцеся да Eaton Гібрыдныя кампаненты і раздым Размяшчэнне месцазнаходжаньня канектараў ў MY08 сістэмах
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
НАТАТКА: звярніцеся да Eaton Гібрыдныя кампаненты і раздым Размяшчэнне месцазнаходжаньня канектараў ў MY09 сістэмах.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”13904|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Інвертар Рухавік / генератар размяшчэнне раздыма перадачы Eaton Fuller” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/eaton-component-connector.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”папярэджання & засцярогі” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]небяспека: Небяспека азначае, што вы будзеце цяжка паранены альбо забіты, калі не будзеце прытрымлівацца ўказанай працэдуры.
папярэджанне: Папярэджанне паказвае на непасрэдную небяспеку, што можа прывесці да цяжкіх цялесных пашкоджанняў, калі вы не будзеце выконваць паказаную працэдуру.
засцярога: Асцярожнасць указвае на пашкоджанне транспартнага сродку або маёмасці, калі вы не будзеце выконваць указаную працэдуру.
Нататка: Заўвага паказвае дадатковую дэталь, якая дапаможа ў дыягностыцы альбо рамонце кампанента / сістэмы.
Выканаеце паказаныя працэдуры ў паказаным парадку, каб пазбегнуць траўмаў:
1. Калі конусы высокага напружання вакол аўтамабіля і блакаванне усталёўваецца на выбарчым участку, адзіны чалавек, які павінен мець магчымасць запуску аўтамабіля з'яўляецца асобай, якія падпісалі блакавальных тэг.
2. Перад пачаткам працы на транспартным сродку ці выхаду з кабіны ў той час як рухавік працуе, Вы павінны змясціць рычаг пераключэння перадач у «N» усталяваны стаяначны тормаз, і блакаваць колы.
3. Па меркаваннях бяспекі, заўсёды задзейнічаць нажной тормаз да выбару пазіцыі перадач ад «N.»
4. Перад тым як пачаць транспартны сродак заўсёды сядзіць на сядзенне кіроўцы, выберыце «N» на кантролі зруху, і ўсталяваць стояночные тормазы.
5. У аўтамабілях з ePTO, рухавік і / або
Рухавік / генератар можа пачацца ў рэжыме ePTO. Ніколі не выконвайце тэхнічнае абслугоўванне або працаваць на транспартным сродку, у той час як у гэтым рэжыме.
6. 12-Volt батарэі станоўчы (+) і адмоўныя (-) павінны быць адключаныя да любой зваркі на любым Гібрыдная абсталяваным аўтамабілі.
засцярога: Выканаеце паказаныя працэдуры ў паказаным парадку, каб пазбегнуць няспраўнасцяў або пашкоджання абсталявання.
засцярога: Не адпускайце стаяначны тормаз і не спрабуйце выбраць перадачу, пакуль ціск паветра не будзе на патрэбным узроўні.
засцярога: Каб пазбегнуць пашкоджання трансмісіі падчас буксіроўкі, пастаўце рычаг пераключэння перадач у становішча "N" і падніміце вядучыя колы ад зямлі альбо адлучыце прывад.
Папярэджання высокага напружання & засцярогі
- Выкарыстанне CO2 ці сухіх хімічных вогнетушыцеляў.
- Драты высокага напружання пакрываюцца ў аранжавых ізаляцыі або згорнутых насосна-кампрэсарных трубах і адзначаны папераджальнымі надпісы на раздымах.
- Усе Eaton® Гібрыдныя Дызельныя / Электрычныя аўтамабілі будуць пазначаныя як «Hybrid’ на вонкавым боку транспартнага сродку, нароўні з цэтлікам зруху на прыборнай панэлі.
- Звярніцеся да OEM для канкрэтнага месцазнаходжаньня шасі ўстаноўлена гібрыдных кампанентаў.
- Ня рэжце ў аранжавыя кабелі высокага напружання.
- НЕ нарэзаць або адкрыць PEC.
- НЕ нарэзаць або адкрыць пераўтваральнік DC / DC.
- НЕ нарэзаць або адкрыць інвертар.
Буферная зона павінна быць ўстаноўлена і высокае напружанне ізаляваны гумовымі пальчаткі (клас 0 скураныя пратэктары) патрабуецца да пачатку працы з высокай напругай. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Гумовыя цеплаахоўныя пальчаткі, якія павінны насіць падчас працы ў сістэме высокага напружання ставяцца да класа 0 скураныя пратэктары. Гумовыя пальчаткі павінны быць правераны перад кожным выкарыстаннем, вынікаючы працэдуры гумавай ізаляцыі пальчаткі выпрабаванні знайшлі ў «Сродкі дыягностыкі / Сэрвіс Публікацыі» на старонцы 6. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Перад аглядам або працаваць на любых кабеляў або высакавольтных кампанентаў на «High-Voltage Shutdown Service і Power-Up Працэдура» на старонцы 4 павінны выконвацца. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Прылады блакіроўкі і Tagout павінны быць выдаленыя толькі з дапамогай тэхнік, якія размешчаны прылады блакіроўкі і Tagout на транспартным сродку. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Высакавольтныя гумовай ізаляцыяй пальчаткі (клас 0 скураныя пратэктары) варта насіць пры працы на любым
Кабелі высокага напружання. «Высакавольтны служба Shutdown і Power-Up Працэдура» на старонцы 4 павінен выконвацца перад выдаленнем любых кабеляў высокага напружання. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Кабелі высокага напружання і провад аранжавыя колеры і ўтрымліваюць папераджальны ярлык на раздымах. кампаненты высокага напружання пазначаныя цэтлікам. Высакавольтныя гумовай ізаляцыяй пальчаткі (клас 0 скураныя пратэктары) павінны быць выкарыстаны пры працы на любым з гэтых кампанентаў. Невыкананне гэтых інструкцый можа прывесці да сур'ёзных траўмам або смерці.
Высакавольтныя працэдуры Service Shutdown
1. Выконвайце «Высакавольтны Працоўная зона» Працэдура.
2. Знайдзіце чырвоны PEC Service Switch на пярэдняй панэлі Пэк і націснуць выключыць.
3. Зніміце вечка Service Switch і ўсталяваць кранштэйн Lockout (J48506).
4. Замацаваць тэг лакаўту кранштэйна.
5. Пераканайцеся, што перамыкач PEC службы не можа перайсці ад выключаны палажэнні.
6. Дайце сістэме ўсталяваць як мінімум 5 хвілін разраду высокага напружання.
7. Падключэнне ServiceRanger і прагляду манітора дадзеных PID 116 пад назвай «High-Voltage патэнцыял батарэі.» Выкарыстанне SPN 520323 для падлучэння J1939 «Напруга батарэі RB» (скрынка рэле).
8. Напружанне павінна быць 30 вольт або менш. Калі напружанне вышэй 30 вольт, не працуюць на транспартным сродку і звязацца Eaton® на 1-800-826-HELP (4357).
9. Павярніце ключ запальвання выключана і прыступіць да рамонту або ліквідацыю непаладак,.
Нататка: Напружанне падае да нуля, калі ключ выключаны.
Высакавольтная служба ўключэнне харчаванне Працэдура
1. Усталюйце ўсе раздымы высокага напружання ў заблакаваным стане.
2. Калі вы чалавек, які працуе на транспартным сродку, выдаліць Lockout кранштэйн і тэг.
3. Усталюйце Lockout кранштэйн праз сэрвісны перамыкач.
4. Выцягнеце Service Switch і дайце набор транспартных сродкаў для 2 хвілін.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Гібрыдныя кампаненты і раздым Размяшчэнне ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Гібрыдныя кампаненты і раздым Размяшчэнне MY09 сістэма” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”КРОК 1. Праверка ИФР цяперашні.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Чытаць далей” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Агляд і прытрымлівацца папярэджання & засцярогі.
- Retrieve Active fault codes and FMIs with ServiceRanger using the 9-Way Diagnostic Connector or manually.
небяспека: глядзець High-Voltage Service Shutdown and Power-Up Procedures. Выканайце працэдуры, каб пазбегнуць ўдару, апёк ці смерць ад няправільна апрацаванага высокага напружання. - ключ ад.
- Якія ИФР прысутнічаюць?
- Калі код няспраўнасці 113 МВФ 6 пералічаны, перайдзіце да кроку 2.
- Калі код няспраўнасці 113 МВФ 14 пералічаны, перайдзіце да кроку 5.
[/fusion_content_box][fusion_content_box title=”КРОК 2. Праверце цэласнасць кабеля пераменнага току.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Чытаць далей” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Візуальна праверце кабель харчавання на наяўнасць прыкмет ізаляцыі, парэзы або адкрытая праводка.
- Remove the AC High-Voltage Cable at the Motor/Generator and Inverter.
- Вымерайце супраціў паміж наступным пераменнага току высокага напружання кабеля Pins:
- A-B
- У-С
- C-A
Нататка: Аўтаналадка лічбавай вольт / Ом метр павінен быць выкарыстаны. - Калі супраціў паміж кожнай фазай з'яўляецца 5M або больш, перайдзіце да кроку 3.
- Калі супраціў знаходзіцца па-за дыяпазону, замяніць пераменнага току высокага напружання Праводка, затым перайдзіце да кроку 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”КРОК 3. Праверце цэласнасць кабеля харчавання пераменнага току на зямлю.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Вымерайце супраціў кожнага пераменнага току высокага напружання кабеля Pin на зямлю.
- Калі супраціў паміж кожным штыром і зямлёй з'яўляецца 5M або больш, замяніць інвертар, затым перайдзіце да кроку 5.
- Калі супраціў знаходзіцца па-за дыяпазону, замяніць кабель высокага напружання пераменнага току, затым перайдзіце да кроку 5.
[/fusion_content_box][fusion_content_box title=”КРОК 4. Праверце бесперапыннасць інвертар для рухавіка / генератара злучэнняў кабеля харчавання пераменнага току.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Чытаць далей” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Зніміце кабель пераменнага току высокага напружання ад інвертар і рухавіка / генератара.
- Вымерайце супраціў кабеля харчавання пераменнага току высокага напружання ад інвертар Раздым для электрарухавіка / генератара раз'ём на кожным з наступных штыфтоў:
- А-А
- У-У
- З-З
Нататка: Аўтаналадка лічбавай вольт / Ом метр павінен быць выкарыстаны.- Калі супраціў менш 1 Ым на кожным контуры, замяніць рухавік / генератар, затым перайдзіце да кроку 5.
- Калі супраціў знаходзіцца па-за дыяпазону, замяніць пераменнага току высокага напружання Праводка, затым перайдзіце да кроку 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”КРОК 4. Праверка і рамонт.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Чытаць далей” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- ключ ад.
- Падлучыце ўсе раздымы і адмоўны кабель акумулятара.
- ключ на.
- ачысціць коды, убачыць Ачысціць Неактыўныя Адмовы.
- Вадзіць аўтамабіль і паспрабаваць скінуць код.
- Праверце коды, убачыць Актыўныя і неактыўныя разломы.
- Калі няма кодаў, тэст завершаны.
- Калі код няспраўнасці 113 з'яўляецца, знайсці памылку ў тэставанні, перайдзіце да кроку 1.
- Калі код, выдатны ад 113 з'яўляецца, убачыць Няспраўнасць Спіс індэксаў код.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]