[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Transmission Felkod 118 – Hjälp High Voltage Relay Kontroll kretsfel
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Felkod för Eaton Hybrid Drive Systems modeller (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P och EH-6E706B-UPG. Läs nedan för att lära hur man testar, rensa och fixa felet kodfel för Freightliner, Mack, Peterbilt, Kenworth, Volvo, Internationell, och tunga lastbilar och utrustning. Hjälphögspänningsreläer, beläget i Power Electric Carrier (PEC), styrs av Hybrid Control Module (HCM). På knappen på, högspännings effekt matas från relä låda till hjälphögspänningsreläer. När alternativet ePTO väljs på tryckknapps Shift Kontroll, HCM aktiverar styrkretsarna för de viktigaste positiva och negativa huvud reläer. Strömmen strömmar sedan genom de extra högspänningsreläer till DC / DC-omvandlare.
felkod 118 – Hjälp High Voltage Relay Kontroll Circuit Fault Detection
Följande förutsättningar måste vara uppfyllda innan systemet upptäcker felet:
- Hybrid Control Module (HCM) tändspänningen är större än 7 volt och mindre än 16 volt.
Notera: När du felsöker en inaktiv kod hänvisar till Produkt Diagnostic läge (PDM)
Förhållanden som Set Fault Code Active
- IMF 3 ställs in när HCM upptäcker en kortslutning till batteriet i spolkretsen på det extra högspänningsreläet.
- IMF 4 sätts när HCM detekterar en kortslutning till jord i spolkretsen hos hjälphögspänningsrelä.
- IMF 5 sätts när HCM detekterar en öppen i spolkretsen hos hjälphögspänningsrelä.
Fallback När felkoder 118 är satt följande situationer uppstår:
- Amber ”Check hybrid” tänds.
- Fel lagras in Hybrid Control Module (HCM) minne.
- DC / DC-omvandlare fungerar inte eftersom HCM de-energizes hjälphögspänningsreläkrets.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Förhållanden som Set Fault Code inaktiv
Endast Inaktiva fel kan tas bort från enheten Transmission Electronic Control (TECU) eller HCM historia med användning ServiceRanger. Den TECU försvinner automatiskt fel från historien efter 200 timmar och HCM stänger automatiskt fel från historien efter det att felet har varit inaktiv under 200 timmar.
Denna felkod kan orsakas av något av följande:
- IMF 3, 4, 5
- OEM ledningar från HCM till PEC
- DC / DC-kabel högspänningsslinga
- DC / DC-omvandlare
- Auxiliary Power Generator (APG) kabel högspänningsslinga (om utrustad)
- APG-omvandlare (om utrustad)
- Extrahögspänningsrelä (insidan PEC)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
felkod 118 – Hjälp High Voltage Relay Kontroll kretsfel Test
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
komponent~~POS=TRUNC:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
NOTERA: Referera till Eaton Hybrid Component och Connector Plats för Connector Platser i MY09 Systems.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14687|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”HCM PEC DC DC APG Connectors Eaton Fuller överföring” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/HCM-PEC-DC-DC-APG-Connectors.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Om fordonet inte är utrustat med APG, en HV interlock keps med slinga bör installeras om fordonet inte är utrustat med en DC / DC, En HV Inter mössa med loop ska installeras.
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”varningar & försiktighetsåtgärder” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]Fara: Fara visar att du kommer att vara allvarligt skadas eller dödas om inte följer den angivna förfarandet.
Varning: Varning indikerar en omedelbar fara, vilket kan leda till allvarliga personskador om du inte följer den angivna förfarandet.
Varning: Försiktighet indikerar fordon eller egendomsskador kan uppstå om du inte följer den angivna förfarandet.
Notera: Anmärkning indikerar ytterligare detaljer som kommer att bistå vid diagnos eller reparation av en komponent / system.
Följ de angivna procedurerna i den angivna för att undvika personskador:
1. Om högspännings kottar är runt fordonet och lockout är installerad på PEC, den enda person som bör tillåtas att starta fordonet är den person som undertecknat lockout tag.
2. Innan du arbetar på ett fordon eller lämna hytten medan motorn är igång, ska du placera växelspaken i ”N” dra åt parkeringsbromsen, och blockera hjulen.
3. Av säkerhetsskäl, alltid engagera färdbromsarna innan du väljer växellägen från ”N.”
4. Innan du startar ett fordon alltid att sitta i förarsätet, välj ”N” på omställningsstyr, och dra åt parkeringsbromsar.
5. I bilar med ePTO, motorn och / eller
Motorn / generatorn kan börja i ePTO-läge. Utför aldrig något underhåll eller arbete på fordon, i det här läget.
6. 12-Volt Battery positiva (+) och negativ (-) måste kopplas bort innan någon svetsning på någon Hybrid utrustat fordon.
Varning: Följ de angivna procedurerna i den angivna för att undvika utrustning fel eller skador.
Varning: Släpp inte parkeringsbromsen och försök att välja en växel tills lufttrycket är på rätt nivå.
Varning: För att undvika skador på växellådan under bogsering plats växelspaken i ”N” och lyfta drivhjulen från marken eller koppla drivlinan.
Högspännings Varningar & försiktighetsåtgärder
- Använd CO2 eller pulver Brandsläckare.
- ledningar högspännings är täckt i orange isolering eller veckad slang och är markerade med varningsetiketter på kontaktdonen.
- Alla Eaton® Hybrid diesel / Elfordon kommer att märkas ’Hybrid’ på utsidan av fordonet, tillsammans med skiftetiketten på instrumentbrädan.
- Se OEM för specifik placering av chassimonterade hybridkomponenter.
- Skär inte i det orangefärgade högspänningskablar.
- Klipp inte in eller öppna PEC.
- Klipp inte in eller öppna DC / DC-omvandlare.
- Klipp inte in eller öppna omriktaren.
Ett buffertzonen måste inrättas och högspänningsisolerade gummihandskar (klass 0 med läderskydd) krävs innan arbetar på högspännings. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Gummiisolerade handskar som måste bäras under arbetet på högspänningssystemet är klass 0 med läderskydd. Gummihandskar bör testas före varje användning efter gummiisoleringshandskar testförfarande finns i ”Diagnostiska Verktyg / Service Publikationer” på sidan 6. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Innan inspektion eller arbetar på alla högspänningskablar eller komponenter ”High Voltage service avstängning och startordningen” på sidan 4 bör följas. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Lockouten och tagout enheter får endast tas bort av teknikern som placerade lockouten och tagout enheter på fordonet. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Högspänningsgummi isolerade handskar (klass 0 med läderskydd) måste användas vid arbete på någon
högspänningskablar. ”High-Voltage service avstängning och startordningen” på sidan 4 måste följas före avlägsnande av eventuella högspänningskablar. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Högspänningskablar och ledningar är orange och innehåller en varningsskylt vid kontakterna. Högspänningskomponenter är markerade med en etikett. Högspänningsgummi isolerade handskar (klass 0 med läderskydd) ska användas vid arbete på någon av dessa komponenter. Underlåtenhet att följa dessa instruktioner kan resultera i allvarlig personskada eller dödsfall.
Högspännings service avstängningsprocedurer
1. Följ ”High-Voltage Work Area” förfarande.
2. Leta reda på röda PEC Tjänst Slå på framsidan av PEC och skjut stänga.
3. Ta bort Service Switch Cover och installera Lockout Bracket (J48506).
4. Fäst tag till Lockout Bracket.
5. Se till att PEC Tjänst Switch kan inte flytta från avstängt läge.
6. Låt systemet för att ställa in minst 5 minuter för att ladda ur högspännings.
7. Anslut ServiceRanger och visa data monitor PID 116 kallad ”High-Voltage Battery potential.” Använd SPN 520323 för J1939 connection ”Battery Voltage RB” (reläbox).
8. Spänningen bör vara 30 volt eller mindre. Om spänningen ligger över 30 volt, fungerar inte på fordonet och kontakta Eaton® på 1-800-826-HELP (4357).
9. Vrid tändningslåset och fortsätt att reparera eller felsökningssteg.
Notera: Spänningen faller till noll när nyckeln är avstängd.
Högspännings service Startprocedur
1. Installera alla högspänningskontakter i sina låsta positioner.
2. Om du är den person som arbetar på fordonet, avlägsna Lockout Bracket och tagg.
3. Sätt tillbaka Lockout Bracket över service Switch.
4. Dra Service Switch och låt bilen set för 2 minuter.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Component och Connector Plats ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Component och Connector Plats MY09 Systems” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 1. Kontrollera Aktiv eller Inaktiv felkod status och FMIS närvarande.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Granska och följ varningar & försiktighetsåtgärder.
- Hämta Aktiva felkoder och FMIS med ServiceRanger användning av 9-Way Diagnostic Connector eller manuellt.
- Key off.
Fara: Se Högspännings service avstängning och påslagning procedurer. Följ anvisningarna för att undvika chock, bränna eller död från hanteras felaktigt högspännings. - Vilket FMIS är närvarande?
- Om FMI 3 är noterat, gå till steg 2.
- Om FMI 4 är noterat, gå till steg 3.
- Om FMI 5 är noterat gå till steg 6.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 2. Mäta spänningen hos HCM Harness till jord.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Koppla bort HCM Harness 38-Way Connector.3. Key på. Koda 88 kommer sätta. Klar fel efter testning.
- Mät spänningen på följande stift på 38- Sätt kabelstammen:
- Stift 33 Till marken
- Stift 5 Till marken
- Om spänningen från Pin 33 till jord och Pin 5 till jord är 0 volt, ersätta HCM (endast om felkod Active), gå sedan till steg 10.
- Om spänningen finns på Pin 33 till jord eller Pin 5 Till marken, koppla bort 19-Way con-nector på PEC och testa.
- Om spänningen är fortfarande närvarande, reparation av fordon Har-ness mellan HCM och PEC.
- Om spänningen är borta efter omprov, gå till steg 3.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 3. Mäta resistansen hos HCM Harness kretsen till jord.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key på.
- Ta 19-Way Connector på PEC. Kontrollera om spänningen på Pin 3 och Pin 4 på PEC.
- Om någon spänning hittas utföra följande steg:
- Ta bort DC / DC-högspänningskabel och omtest.
- Avlägsna APG högspänningskabel och omtest.
- Ersätta PEC om spänningen är fortfarande närvarande.
- Om någon spänning hittas utföra följande steg:
- Om ingen spänning finns, mäta motståndet PEC 19-Way Connector på följande stiften:
- Stift 3 till Pin 7
- Stift 3 till Pin 10
- Stift 3 till Pin 14
- Stift 3 till PEC monterings stud
- Om ohm är öppen krets, återansluta DC / DC-högspänningskabel och APG högspänningskabel och omtest. Om fortfarande en öppen krets, gå till steg 2.
- Om ohm visar kortsluten krets, ta bort DC / DC och APG högspänningskablar. Om fortfarande sluten, ersätta PEC. Efter reparationer görs, gå till steg 10.
- Om kort är isolerad till 1 högspänningskabel, kontrollera kabel och komponent och ohm kabel förreglingar ände mot ände. Om de är bra, ersätta kortslutna komponenten (DC / DC-omvandlare eller APG Converter).
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 4. Test för en kortslutning till jord på fordons Harness från HCM till PEC.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off
- Koppla bort HCM 38-Way Connector. PEC 19- Way Connector ska anslutas.
- Mäta motståndet hos 38-Way Connector på Pin 33 Till marken.
- Om resistansen är OL, ersätta HCM. Se Hybrid Control Module (HCM) Demontering och montering förfarande TRSM2000.
- Om resistansen visar en kort i kretsen till jord, koppla bort 19-vägskopplingen i PEC och testa Pin 33 Till marken.
- Om kort är fortfarande närvarande, reparera fordonet kabelnätet mellan HCM och PEC
- Om kort är borta, gå till steg 5.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 5. Mäta motstånd från DC / DC-omvandlare till jord.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Koppla bort 19-vägskopplingen från PEC.
- Mäta resistans på PEC 19-Way Connector på följande stiften:
- Stift 3 till Pin 7
- Stift 3 till Pin 10
- Stift 3 till Pin 14
- Stift 3 till PEC monterings stud
- Om resistansen visar OL, gå till steg 4. testa igen.
- Om resistansen visar korta i kretsen till jord, avlägsna högspänd DC / DC och APG kablar en i taget för att isolera kretsen med kort.
- Om kort finns i en av hjälphögspänningskablar, ta bort högspänningskabel och ohm spärrstiften ände mot ände. Om kabeln är bra, ersätta kortslutna komponenten (DC / DC-omvandlare eller APG Converter).
- Om resistansen visar fortfarande kort med hög-volts-ålders kablar avlägsnade, ersätta PEC. Se MY09 Ström Electric Carrier (PEC) Demontering och montering förfarande TRSM2000. Efter reparationer är klara, gå till steg 10.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 6. Mäta motstånd från DC / DC-omvandlare till jord.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off
- Ta bort 19-vägskopplingen från PEC.
- Mäta motståndet på följande stiften på PEC Connector:
- Stift 3 till Pin 4
- Om resistansen är 12-22 ohm, gå till steg 9.
- Om resistansen är OL, gå till steg 7.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 7. Verifiera kontinuiteten hos DC / DC-kabel.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Ta bort DC / DC högspänningskabel på PEC. Låt kabeln vara ansluten till DC/DC-omvandlaren.
Notera: Om inte är utrustad med DC / DC-omvandlare, kontrollera Cap Inter Loop. - Mät motstånd DC / DC högspänningskabel Interlock Pins.
- Om resistansen är 0-0,3 ohm, gå till steg 8.
- Om resistansen är OL, ta bort DC/DC-högspänningskabel och ohm-spärrstift från ände till ände.
- Om kabelresistans är OL, ersätta DC / DC-kabel.
- Om kabelresistans är 0-0,3 ohm, ersätta DC / DC-omvandlare. Se DC / DC-omvandlare Demontering och montering förfarande TRSM2000. Efter reparationer är klara, gå till steg 10.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 8. Kontrollera kontinuiteten i APG kabeln.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Ta APG kabeln från PEC. Lämna kabeln ansluten vid APG-änden.
Notera: Om inte är utrustad med APG, kontrollera Cap Inter Loop - Mät motstånd APG högspänningskabel Interlock Pins.
- Om resistansen är 0-0,3 ohm, ersätta PEC. Se MY09 Ström Electric Carrier (PEC) Demontering och montering förfarande TRSM2000. Efter reparationer görs, gå till steg 10.
- Om resistansen är OL, avlägsna APG högspänningskabel. Mäta Interlock Pins end-to-end.
- Om kabelresistans är OL, byt ut APG högspänningskabel.
- Om kabelresistans är 0-0,3 ohm, ersätta APG. Efter att reparationer, gå till steg 10.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 9. Mäta resistansen hos HCM.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
Notera: Detta steg utförs efter att mäta ohm på Pin 3 och Pin 4 och de mätt mellan 12-22 ohm. - Ta bort 38-Way Vehicle kabelnät.
- Ta bort 19-vägskopplingen på PEC.
- Mäta följande stiften mellan 38-vägskopplingen och 19-Way Connector:
- Stift 33 (38-Way Connector) till Pin 3 (19-Way Connector).
- Stift 5 (38-Way Connector) till Pin 4 (19-Way Connector).
- Om resistansen är OL, reparation av fordon kabelnätet mellan HCM och PEC.
- Om resistansen är mellan 0-0,3 ohm, ersätta HCM. Se Hybrid Control Module (HCM) Demontering och montering förfarande TRSM2000. Efter reparationer görs, gå till steg 10.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”1″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEG 10. verifiera reparation.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Läs mer” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key off.
- Anslut alla kontakter.
- Key på.
- Dra ut röda service Slå på PEC.
- tydliga koder, se Tydliga Inaktiva fel.
- Kör fordonet och försöka återställa koden.
- Kontrollera om koder, se Visa aktiva och inaktiva fel.
- Om inga koder, testet är klart.
- Om felkoden 118 visas, hitta fel i test, gå till steg 1.
- Om annan kod än 118 visas, se Felkod Index List.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]