[fusion_builder_container hundred_percent=yeshundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Fout Kode 24 – J1939 HCM Boodskap (TECU)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fout kode vir Eaton Hybrid Drive Systems modelle (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-O / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P en EH-6E706B-UPG. Die Eenheid Transmissie Elektroniese Beheer (TECU) kommunikeer met die Hybrid Control Module (HCM) oor die skakel J1939 data tydens die operasie voertuig te versoek rat en huidige rat inligting uit te ruil.

fout Kode 24 – J1939 HCM Boodskap (TECU) opsporing

Die volgende voorwaardes voldoen moet word voordat die stelsel die skuld ontdek:

  • TECU ontsteking spanning groter as 7 volt en minder as 16 volts.
  • No J1939 data link fault currently Active in the TECU.

Voorwaardes te stel Fout Kode Active

  • IMF 9 is ingestel wanneer die TECU versuim om data-oordrag te ontvang (soos 'n versoek rat) vir 2 sekondes of meer van die HCM, en dit is nog te kommunikeer met ander modules op J1939.

Nood Wanneer Fout Kode 24 is ingestel op die volgende voorwaardes voorkom:

  • Rooi "Service" lig verlig, en 'n "F" flitse in die rat vertoning.
  • Skuld gestoor in TECU geheue.
  • Werking af veranderings aan AutoShift Terugval af.
  • As die fout sit op krag tot, the engine does not crank.
  • As die fout stelle terwyl jy ry, die voertuig bly in die huidige rat. Wanneer die voertuig tot stilstand kom die koppelaar oopmaak en bly in hierdie posisie.
  • Amber “Check Hybrid” light may display on the dash due to an Active fout Kode 48.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Voorwaardes te stel Fout Kode Stil

Slegs Stil foute kan skoongemaak word van die TECU of HCM geskiedenis met behulp van ServiceRanger. Die TECU goedkeuring outomaties foute uit die geskiedenis na 200 ure. Die HCM goedkeuring van 'n fout van die geskiedenis outomaties nadat dit Stil voor was 200 ure.

Hierdie fout kode kan veroorsaak word deur enige van die volgende:

  • IMF 9
    • J1939 Data Link
    • HCM

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

fout Kode 24 – J1939 HCM Boodskap (TECU) toets

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Komponent Identifikasie MY08 System:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14126|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Tuig Front View TECU – Voertuig Interface Connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Harness-Front-View-TECU.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Tuig Front View
TECU – Voertuig Interface Connector

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14061|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Span Front View (HCM – Voertuig Interface Connector)” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Tuig Front View
(HCM – Voertuig Interface Connector)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTA: Verwys na die Eaton Hybrid komponent en Connector ligging vir Connector plekke in MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOTA: Verwys na die Eaton Hybrid komponent en Connector ligging vir Connector plekke in MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14163|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Fuller TECU HCM connector” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-TECU-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”waarskuwings & waarsku” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]gevaar: Gevaar dui jy sal erg beseer of gedood as moenie die aangedui prosedure volg nie.
waarskuwing: Waarskuwing dui op 'n onmiddellike gevaar, wat kan lei tot ernstige persoonlike besering as jy nie die aangewese prosedure te volg.
versigtigheid: Let daarop dui voertuig of skade aan eiendom kan optree as jy nie die aangewese prosedure te volg.

nota: Nota dui addisionele detail wat sal help met die diagnose of herstel van 'n komponent / stelsel.

Volg die gespesifiseerde prosedures in die aangeduide om persoonlike beserings te voorkom:

1. As die hoë-spanning keëls is om die voertuig en die uitsluiting is geïnstalleer op die PUK, die enigste persoon wat toegelaat moet word om die voertuig begin is die persoon wat die uitsluiting tag onderteken.
2. Voor die werk op 'n voertuig of verlaat die kajuit, terwyl die enjin loop, moet jy die rathefboom in "N" plaas het die parkeerrem, en sluit die wiele.
3. Om veiligheidsredes, altyd die diens remme betrek voor die kies van rat posisies van "N."
4. Voor die aanvang van 'n voertuig altyd sit in die bestuurder se sitplek, kies "N" op die verskuiwing beheer, en stel die parkering remme.
5. In voertuie met ePTO, die enjin en / of
Motor / Generator kan begin in ePTO af. voer nooit enige onderhoud of werk op voertuig, terwyl in hierdie modus.
6. 12-Volt battery positiewe (+) en negatiewe (-) moet voor ontkoppel om enige sweiswerk op enige Hybrid toegerus voertuig.

versigtigheid: Volg die gespesifiseerde prosedures in die aangeduide om toerusting wanfunksioneer of skade te vermy.
versigtigheid: Moenie die parkeerrem nie vry te laat of te poog om 'n rat kies totdat die lugdruk is op die regte vlak.
versigtigheid: Om skade aan die oordrag tydens sleep plek die rathefboom in "N" te vermy en die opheffing van die ry wiele van die grond af of ontkoppel die aandrijflijn.

Hoë-spanning Waarskuwings & waarsku

  • Gebruik CO2 of droë chemiese brandblussers.
  • Die hoë-spanning bedrading bedek in oranje isolasie of ingewikkelde pype en gemerk met waarskuwing etikette op die verbindings.
  • Alle Eaton® Hybrid Diesel / Electric voertuie sal gemerk word "Hybrid’ aan die buitekant van die voertuig, saam met die verskuiwing etiket op die paneelbord.
  • Verwys na OEM vir spesifieke plek van onderstel gemonteer hibriede komponente.
  • MOENIE sny in die oranje hoë-spanning kabels.
  • MOENIE sny in of maak die PUK.
  • MOENIE sny in of die DC / DC Converter oop.
  • MOENIE sny in of maak die Inverter.

'N buffersone moet opgestel word en 'n hoë-spanning geïsoleerde rubberhandskoene (klas 0 met leer beskermers) is voor wat nodig is om die werk op 'n hoë-spanning. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.
Die rubber geïsoleerde handskoene wat moet gedra word, terwyl die werk op die hoë-spanning stelsel is klas 0 met leer beskermers. Die rubberhandskoene moet getoets word voor elke gebruik na aanleiding van die rubber isolasie handskoene toetsprosedure gevind in "diagnostiese instrumente / Service Publications" op bladsy 6. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.
Voor te inspekteer of werk op 'n hoë-spanning kabels of komponente van die "High-spanning Service Afsluiting en Power-Up Prosedure" op bladsy 4 gevolg moet word. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.
Die Uitsluiting en Tagout toestelle moet net verwyder word deur die tegnikus wat die Uitsluiting en Tagout toestelle op die voertuig geplaas. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.
Hoë-spanning rubber geïsoleerde handskoene (klas 0 met leer beskermers) moet gedra word wanneer daar op 'n
hoë-spanning kabels. Die "Hoogspannings Service Afsluiting en Power-Up Prosedure" op bladsy 4 moet voor wat gevolg moet word om die verwydering van 'n hoë-spanning kabels. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.
Hoë-spanning kabels en bedrading is oranje en bevat 'n waarskuwing etiket op die verbindings. Hoë-spanning komponente gemerk met 'n etiket. Hoë-spanning rubber geïsoleerde handskoene (klas 0 met leer beskermers) moet gebruik word wanneer daar op enige van hierdie komponente. Versuim om hierdie instruksies te volg kan lei tot ernstige persoonlike besering of dood.

Hoë-spanning Service Shutdown Prosedures

Hoë-spanning Service Afsluiting en Power-Up Prosedure1. Volg "Hoogspannings Werk Area" prosedure.
2. Vind die rooi PEC Service Skakel die voorkant van die PAC en stoot afskakel.
3. Verwyder die Diens Skakel Cover en installeer die Uitsluiting Bracket (J48506).
4. Vas tag om die Uitsluiting Bracket.
5. Verseker die PUK Service Switch kan nie beweeg van die af posisie.
6. Laat die stelsel op te rig vir 'n minimum van 5 minute om 'n hoë spanning ontlaai.
7. Verbind ServiceRanger en kyk na die data Monitor PID 116 genaamd "High-spanning Potensiële Battery." Gebruik SPN 520323 vir J1939 verband "Battery Voltage RB" (Relay Box).
8. Die spanning moet wees 30 volts of minder. As die spanning is bo 30 volts, werk nie op die voertuig en kontak Eaton® by 1-800-826-HELP (4357).
9. Draai aansitsleutel af en gaan na herstel of stap probleem op te los.
nota: Die spanning daal tot nul wanneer die sleutel is af.

Hoë-spanning Service Power-Up Prosedure

1. Installeer al 'n hoë-spanning verbindings in hul toegesluit posisies.
2. As jy die persoon wat op die voertuig, verwyder die Uitsluiting Bracket en tag.
3. Installeer die Uitsluiting Bracket oor die Diens Skakel.
4. Trek die Diens Skakel uit en laat voertuig stel vir 2 minute.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid komponent en Connector ligging ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent en Connector Locations MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid komponent en Connector ligging MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid komponent en Connector Locations MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 1. Check vir Active of Stil skuld-kode status en uit te voer Elektriese voortoets.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees meer” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Haal Active skuld kodes en FMIS met ServiceRanger met behulp van die 9-Way Diagnostiese Connector.
  2. Voer die Elektriese voortoets.
    • As geen probleme gevind tydens die Elektriese voortoets, gaan na Stap 2.
    • As kwessie is herstel tydens die Elektriese voortoets, gaan na Stap 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=STAP 2. Verifieer kontinuïteit van Voertuig Span.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lees meer” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. sleutel af.
  2. Ontkoppel negatiewe battery kabel.
  3. Disconnect HCM Vehicle Harness 38- manier Connector.
  4. Measure resistance between HCM Vehicle Harness 38- Manier Connector Pin 2 en Pin 3:
    nota: Maak seker dat die Volt / Ohm Meter is op die regte skaal (rondom 200 ohm skaal).

    • As weerstand tussen Pin 2 en Pin 3 is tussen 50-70 ohm, vervang die Hybrid Control Module (HCM), dan gaan na Stap 3.
    • As weerstand is buite bereik, herstel J1939 Data skakel Span, dan gaan na Stap 3.

[/fusion_content_box][fusion_content_box title=STAP 3. verifieer Repairbackgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. sleutel af.
  2. Herkonnekteer al verbindings en negatiewe battery kabel.
  3. sleutel op.
  4. duidelik kodes, sien Duidelik Stil Foute.
  5. Ry die voertuig en probeer om die kode te herstel.
  6. Check vir kodes, sien Kyk Active en Stil Foute.
    • Indien geen kodes, toets is voltooi.
    • As skuld Kode 24 verskyn, vind fout in die toets, gaan na Stap 1.
    • As 'n kode buiten 24 verskyn, sien Fout Kode Index Lys.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]