Eaton Fuller Hybrid Fout Kode 6 – No HCM Operation

Fout kode vir Eaton Hybrid Drive Systems modelle (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-O / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P en EH-6E706B-UPG. Die Hybrid Control Module (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

fout Kode 6 – No HCM Operation Detection

Die volgende voorwaardes voldoen moet word voordat die stelsel die skuld ontdek:

  • HCM ontsteking spanning groter as 7 volt en minder as 16 volts.

Voorwaardes te stel Fout Kode Active

Voorwaardes te stel Fout:

  • IMF 12 is set at key on if the HCM detects an internal failure.
  • IMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Nood Wanneer Fout Kode 6 is ingestel op die volgende voorwaardes voorkom:
• Amber "Check Hybrid" lig verlig.
• If the fault occurs at power up the vehicle may not crank.

Voorwaardes te stel Fout Kode Stil

Slegs Stil foute kan skoongemaak word van die Eenheid Transmissie Elektroniese Beheer (TECU) of HCM geskiedenis met behulp van ServiceRanger. Die TECU goedkeuring outomaties die foute uit die geskiedenis na 200 ure. Die HCM goedkeuring outomaties die foute uit die geskiedenis na die fout Stil vir 200 ure.

Hierdie fout kode kan veroorsaak word deur enige van die volgende:

  • IMF 12, 14
    • HCM

fout Kode 6 – No HCM Operation Test