Eaton Fuller Hybrid Transmission Fault Code 58 – Output Shaft Speed Sensor

Fault code for Eaton Hybrid Drive Systems models (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U/P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P and EH-6E706B-UPG. Read below to learn how to test, clear and fix fault code errors for your Freightliner, Mack, Peterbilt, Kenworth, Volvo, International, and heavy-duty truck and equipment. The Output Shaft Speed Sensor is located on the rear bearing cover at the 12 o’clock position. The sensor is a magnetic pickup that produces an AC voltage as the tone wheel teeth moves past the end of the sensor. At idle, the Speed Sensor output is low and it increases as the speed of the output shaft increases.

Fault Code 58 – Output Shaft Speed Sensor Detection

The following preconditions must be met before the system detects the fault:

  • Transmission Electronic Control Unit (TECU) ignition voltage is greater than 7 volts and less than 16 volts.
  • FMI 2 does not set if there is already an Active FMI 5 for the Input or Output Shaft Speed Sensors.

Note: When troubleshooting an Inactive code refer to the Product Diagnostic Mode (PDM)

Conditions to Set Fault Code Active

  • FMI 2 is set when the TECU output shaft speed is compared to the input shaft speed and it produces an inconsistent reading for 1 second or greater.
  • FMI 3, 4 are set when the TECU detects a short to ground, short to battery, or the output shaft speed is 0 for 1 second or greater.
  • FMI 5 is set when the TECU detects an open circuit and the Output Shaft Speed Sensor is 0 for 1 second or greater.

Fallback When Fault Code 58 is set the following conditions occur:

  • Red “Service” light illuminates and an “F” flashes in the gear display.
  • Fault is stored in TECU memory.
  • Operation mode changes to “AutoShift Fallback” mode.
  • If this fault occurs while moving, the transmission remains in the current gear and the clutch opens when the vehicle stops.

Conditions to Set Fault Code Inactive

Only Inactive faults can be cleared from the Transmission Electronic Control Unit (TECU) or HCM history using ServiceRanger. The TECU automatically clears the faults from history after 200 hours and the HCM automatically clears the faults from history after the fault has been Inactive for 200 hours.

This fault code can be caused by any of the following:

  • FMI 2
    • Output Shaft Speed Sensor
    • TECU
    • Transmission Harness
    • Damaged Transmission Gearing
    • Contamination on the Output Shaft Speed Sensor
  • FMI 3, 4, 5
    • Output Shaft Speed Sensor
    • TECU
    • Transmission Harness

Fault Code 58 – Output Shaft Speed Sensor Test

Component Identification:

Harness Front View TECU - Vehicle Interface Connector for Fuller transmission

Harness Front View
(TECU – System Interface Connector)

Output Shaft Speed Sensor

Output Shaft Speed Sensor

NOTE: Refer to the Eaton Hybrid Component and Connector Location for Connector Locations in MY08 Systems

NOTE: Refer to the Eaton Hybrid Component and Connector Location for Connector Locations in MY09 Systems.

TECU Output Shaft Speed Sensor connector location Eaton Fuller transmission