Hybrid Eaton Fuller Gudbinta Babaca Code 38 – Battery Fan Relay

Khalad code for Hybrid Eaton daydo Systems Drive (MY08) Cuneyso-8E306A-U, Cuneyso-8E306A-UPG, Cuneyso-8E306A-UP, Cuneyso-8E306A-CD, Cuneyso-8E306A-T, Cuneyso-6E606B-CD, (MY09) Cuneyso-8E406A-U / P, Cuneyso-8E406A-UP, Cuneyso-8E406A-UPG, Cuneyso-8E406A-CD, Cuneyso-8E406A-CDG, Cuneyso-8E406A-guud, Cuneyso-8E406A-T, Cuneyso-6E706B-CD, Cuneyso-6E706B-P iyo aad cuneyso-6E706B-UPG. The Battery Fan Relay sida caadiga ah waa Relay furan ku xiran Control Module ku Hybrid (Gudiga sare) dhinaca ay gacanta ku. Marka awoodaha Gudiga sare ee circuit gacanta, waxa ay xirtey xiriirada Relay iyo jirsado on Relay ah. Awoodaha Battery Fan Relay Fan Battery ku yaalla Power Electronics Carrier ah (PEC), qaboojinta ah baytariyada a high-voltage.

khalad Code 38 – Battery Fan Relay Ogaanshaha

The shuruud soo socda waa in la buuxiyaa ka hor inta nidaamka ogaadaa gardarrada:

  • Gudiga sare danab suuroggalaan waa ka weyn yahay 7 volts iyo ka yar 16 volts.

Note: Marka dhib code ah Wax qabad la'aan tixraac ah Product Baarista Mode (PDM)

Xaaladaha in Calan Babaca Code Active

Xaaladaha in Calan Babaca:
• IMF 3 ayaa lagu wadaa markii danab shidma ka wada weyn yahay 4.1 volts waayo, 10 seconds, halka heerkulka Inverter ay ka badan tahay 35 ° C ama 95 ° F, ama haddii danab saarka shidma uu ka yar yahay 0.2 volts waayo, 10 seconds.

Uugu Marka Babaca Code 38 ayaa lagu wadaa shuruudaha soo socda dhici:

  • IMF 3 ayaa lagu wadaa markii Gudiga sare ee ogaadaa gaaban si batteriga ee circuit gariiradda ee Fan Battery ee Relay ah.
  • IMF 4 ayaa lagu wadaa markii Gudiga sare ee ogaadaa gaaban dhulka wareegi gariiradda ee Fan Battery ee Relay ah.
  • IMF 5 ayaa lagu wadaa markii Gudiga sare ee ogaadaa furan wareegi gariiradda ee Fan Battery ee Relay ah.
  • IMF 14 ayaa lagu wadaa marka shuruudaha soo socda waa run, waayo, 10 daqiiqo:
    • High-voltage battery temperature is greater than 131 ° F (55 ° C)
    • Farqiga u dhexeeya heerkulka ugu yaraan iyo ugu badnaan batteriga ka yar tahay 33 ° F (1 ° C)
    • No heerkulka batari unu ka Control Battery ku Module

Xaaladaha in Calan Babaca Code qabad la'aan

Kaliya unu qabad la'aan la nadiifiyay karaa Unit Gudbinta Electronic Control ah (TECU) ama taariikhda HCM isticmaalaya ServiceRanger. TECU ayaa si toos ah oo ansixiyay unu ka dib markii taariikhda 200 saacadood iyo HCM si toos ah oo ansixiyay unu ka soo taariikhda ka dib qalad uu Wax qabad la'aan, waayo, 200 saacadood.

code qalad Tani waxaa keeni kara wax ka mid ah kuwan soo socda:

  • IMF 3, 4, 5
    • Vehicle suunka ka HCM si Battery Fan Relay
    • Battery Fan Relay
    • Gudiga sare
  • IMF 14
    • Battery Fan Relay
    • Battery Fan
    • Shidan Filter Air
    • Battery Fan Relay korontada ugu weyn

khalad Code 38 – Battery Fan Relay Test

Aqoonsiga Qeybta:

Front Harness View HCM - Hybrid System Interface Connector

Front la habeeyo View
Gudiga sare – Hybrid System Wajahadda Connecto

Harness Connector View (PEC 19 - Way)

La habeeyo isku xira View
(PEC 19 – Jidka)

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY08

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY09.

Eaton HCM Battery Fan Relay PEC Battery connector

Qof kasta oo gudbinta qayb aad u baahan tahay aynu u leeyihiin! maalin isku mid ah maraakiibta la heli karo, dunida oo dhan.

U BAAHAN TAAGEERO FREE KA MID khubaro OUR?

WAC NOW