[fusion_builder_container hundred_percent=”yes” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ایتون فولر ترکیبی کد خطا انتقال 33 – ولتاژ باتری کم (TECU)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
خطا کد برای ایتون ترکیبی مدل های سیستم درایو (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P و EH-6E706B-UPG. واحد کنترل الکترونیکی گیربکس (TECU) به انتقال نصب شده و شامل نرم افزار برای کنترل عملیات انتقال; با این حال, ماژول کنترل ترکیبی (HCM) کنترل بهره برداری از TECU در طول عملیات حالت ترکیبی طبیعی. HCM به قدرت باتری اصلی ذوب خوراک 12 ولت اجرا می شود که از طریق HCM 38-راه خودرو اتصال با سیم زمین اصلی بازگشت به ترمینال منفی باتری است.
خطا کد 33 – ولتاژ باتری کم (TECU) کشف
پیش شرط زیر باید رعایت شود قبل از سیستم تشخیص گسل:
- ولتاژ جرقه TECU بزرگتر از 7 ولت و کمتر از 16 ولت.
شرایط به تنظیم کد گسل فعال
- صندوق بین المللی پول 4 قرار است که ولتاژ باتری TECU قطره زیر 7 ولت برای بیش از 1 دومین.
جانشین هنگامی که کد خطا 33 قرار است شرایط زیر رخ می دهد:
- گسل است که در حافظه ذخیره می شود TECU.
- بدون چراغ در فشار دکمه روشن.
- اگر این گسل رخ می دهد قبل از به قدرت بالا, وسیله نقلیه نمی خواهد خم.
- اگر این گسل رخ می دهد در حالی که رانندگی, خودرو حفظ دنده فعلی. کلاچ باز می شود هنگامی که وسیله نقلیه متوقف می شود.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
شرایط به تنظیم گسل کد غیر فعال
فقط گسل غیر فعال را می توان از واحد انتقال کنترل الکترونیکی پاک (TECU) و یا سابقه HCM با استفاده از ServiceRanger. TECU به طور خودکار پاک گسل از تاریخ، پس از 200 ساعت و HCM به طور خودکار پاک گسل از تاریخ پس از گسل است برای غیر فعال شده 200 ساعت ها.
این کد خطا را می توان با هر یک از موارد زیر ایجاد:
- صندوق بین المللی پول 4
- منبع تغذیه به TECU
- باتری پایین یا بد اتصال به قدرت اصلی
- سیستم شارژ
- TECU
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
خطا کد 33 – پایین تست ولتاژ باتری
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
سیستم های ترکیبی شناسایی MY08:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14135|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”فولر مهار جبهه نمایش TECU – خودرو رابط اتصال” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Harness-Front-View-TECU-Vehicle-Interface-Connector.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
مهار جبهه نمایش (TECU – خودرو رابط اتصال)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
توجه داشته باشید: به مراجعه ایتون و اجزای ترکیبی و اتصال محل سکونت برای مکان های اتصال در سیستم MY08
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
توجه داشته باشید: به مراجعه ایتون و اجزای ترکیبی و اتصال محل سکونت برای مکان های اتصال در سیستم MY09.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”” background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14181|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”ایتون فولر TECU رابط باتری” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/TECU-to-battery-connector.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”هشدارها & هشدار” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]خطر: خطر را نشان می دهد به شما خواهد شد به شدت مجروح و یا کشته اگر انجام این روش نشان داد پیروی نمی.
هشدار: هشدار نشان می دهد خطر فوری, که می تواند در آسیب شدید شخصی در نتیجه اگر شما انجام این روش نشان داد پیروی نمی.
احتیاط: توجه نشان می دهد خودرو یا خسارت می تواند رخ دهد اگر شما روش نشان داد پیروی نمی.
توجه داشته باشید: توجه نشان می دهد جزئیات اضافی که در تشخیص و یا تعمیر یک جزء / سیستم کمک خواهد کرد.
دنبال روش مشخص شده در جهت نشان داد برای جلوگیری از آسیب های شخصی:
1. اگر مخروط با ولتاژ بالا در سراسر وسیله نقلیه هستند و قفل بر روی PEC نصب, تنها کسی که باید اجازه داده شود برای شروع وسیله نقلیه شخصی که برچسب قفل امضا است.
2. قبل از کار بر روی یک وسیله نقلیه و یا خروج از کابین در حالی که موتور در حال اجرا است, شما باید دسته دنده در "N" قرار دهید مجموعه ترمز دستی, و جلوگیری از چرخ.
3. به دلایل ایمنی, همیشه درگیر ترمز خدمات قبل از انتخاب موقعیت دنده از "N"
4. قبل از شروع یک خودرو همیشه در صندلی راننده نشسته, را انتخاب کنید "N" در کنترل شیفت, و تنظیم ترمز پارکینگ.
5. در وسایل نقلیه با ePTO, موتور و / یا
موتور / ژنراتور می تواند در حالت ePTO شروع. هرگز از تعمیر و نگهداری انجام و یا کار بر روی خودرو, در حالی که در این حالت.
6. 12-ولت باتری مثبت (+) و منفی (-) باید قبل از هر گونه جوش روی هر وسیله نقلیه هیبریدی مجهز قطع شود.
احتیاط: دنبال روش مشخص شده در جهت نشان داد برای جلوگیری از نقص تجهیزات و یا آسیب.
احتیاط: هنوز ترمز دستی را آزاد و یا تلاش برای انتخاب یک دنده تا زمانی که فشار هوا در سطح درست.
احتیاط: برای جلوگیری از آسیب به انتقال در طول بکسل جای دسته دنده را در "N" و بلند چرخ دیسک به خارج از زمین و یا قطع سیستم نیروی محرکه.
هشدار ولتاژ بالا & هشدار
- استفاده از CO2 و یا خشک شیمیایی آتش خاموش.
- سیم کشی با ولتاژ بالا در عایق نارنجی و یا لوله پیچیده پوشیده شده و مشخص شده با برچسب های هشدار دهنده در اتصالات.
- همه Eaton® ترکیبی دیزل / وسایل نقلیه الکتریکی خواهد شد مشخص شده، ترکیبی’ در خارج از خودرو, همراه با برچسب تغییر در فاصله.
- برای محل خاصی از شاسی سوار شده اجزای ترکیبی به نصب مراجعه کنید.
- هنوز نه به رنگ نارنجی کابل ولتاژ بالا قطع.
- آیا به قطع نیست و یا باز کردن PEC.
- آیا به قطع نیست و یا باز کردن مبدل DC / DC.
- آیا به قطع نیست و یا باز کردن اینورتر.
یک منطقه حائل باید راه اندازی و ولتاژ بالا عایق دستکش خانگی لاستیک (کلاس 0 با پشتوانه چرم) به کار بر روی ولتاژ بالا قبل مورد نیاز. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
دستکش لاستیکی عایق است که باید در حالی که کار بر روی سیستم های با ولتاژ بالا پوشیده می شود کلاس 0 با پشتوانه چرم. دستکش لاستیکی باید قبل از هر استفاده به روش لاستیک تست دستکش عایق در "وسایل تشخیصی / انتشارات خدمات" در صفحه پیدا شده است مورد آزمایش قرار 6. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
قبل از بازرسی یا کار بر روی هر گونه کابل ولتاژ بالا یا اجزای "ولتاژ بالا خاموش کردن خدمات و قدرت بالا روش" در صفحه 4 باید به دنبال. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
دستگاه های تحریم و Tagout تنها باید توسط تکنسین که دستگاه قفل و Tagout بر روی وسیله نقلیه قرار داده شده حذف. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
انتقال انرژی الکتریکی به لاستیک عایق دستکش (کلاس 0 با پشتوانه چرم) باید هنگام کار با هر پوشیده می شود
کابل ولتاژ بالا. از "خاموش کردن ولتاژ بالا خدمات و قدرت بالا روش" در صفحه 4 باید قبل از از بین بردن هر گونه کابل ولتاژ بالا دنبال شود. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
کابل ولتاژ بالا و سیم کشی نارنجی هستند و شامل یک برچسب هشدار دهنده در اتصالات. قطعات ولتاژ بالا با برچسب مشخص شده. انتقال انرژی الکتریکی به لاستیک عایق دستکش (کلاس 0 با پشتوانه چرم) باید هنگام کار بر روی هر یک از این قطعات استفاده می شود. عدم پیروی از این دستورالعمل ممکن است در آسیب شخصی شدید یا مرگ می شود.
ولتاژ بالا روش خاموش کردن خدمات
1. دنبالکردن "ولتاژ بالا فضای کار" روش.
2. تعیین محل قرمز تغییر PEC خدمات در جلو از PEC و فشار خاموش.
3. حذف پوشش خدمات سوئیچ و نصب براکت تعطیل کار (J48506).
4. برچسب ببندید به تحریم براکت.
5. اطمینان از تغییر PEC خدمات نمی تواند از در وضعیت خاموش حرکت.
6. اجازه می دهد که سیستم به مجموعه ای برای حداقل 5 دقیقه به تخلیه ولتاژ بالا.
7. اتصال ServiceRanger و مشاهده مانیتور داده PID 116 به نام "بالقوه باتری با ولتاژ بالا." استفاده از SPN 520323 برای اتصال J1939 "ولتاژ باتری RB" (جعبه رله).
8. ولتاژ باید 30 ولت یا کمتر. اگر ولتاژ بالا است 30 ولت, بر روی خودرو کار نمی کند و تماس Eaton® در 1-800-826-HELP (4357).
9. کلید احتراق کردن و اقدام به تعمیر و یا گام عیب یابی.
توجه داشته باشید: ولتاژ قطره به صفر زمانی که کلید خاموش است.
ولتاژ بالا خدمات قدرت بالا روش
1. نصب تمام اتصالات با ولتاژ بالا را در موقعیت های قفل شده خود.
2. اگر شما فرد کار بر روی خودرو, حذف تحریم براکت و برچسب.
3. نصب مجدد تحریم براکت بیش از سوئیچ خدمات.
4. نگه دار، خدمات SWITCH و اجازه دهید مجموعه ای وسیله ای برای 2 دقایق.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”ایتون و اجزای ترکیبی و اتصال محل سکونت ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”ایتون و اجزای ترکیبی و اتصال محل سکونت MY09 سیستم” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”گام 1. برای وضعیت کد گسل فعال و یا غیر فعال بررسی و انجام پیش آزمون برق.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”ادامه مطلب” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- بازیابی کدهای گسل فعال و FMIS با ServiceRanger با استفاده از 9 راه تشخیصی اتصال.
- انجام پیش آزمون برق.
- اگر کد خطا 33 پس از انجام پیش آزمون برق فعال است, جایگزین واحد انتقال کنترل الکترونیکی (TECU) (تنها اگر کد گسل فعال است), سپس به گام 2.
• اگر کد خطا 33 پس از انجام پیش آزمون برق غیر فعال است, کد روشن و رفتن به مرحله 2.
- اگر کد خطا 33 پس از انجام پیش آزمون برق فعال است, جایگزین واحد انتقال کنترل الکترونیکی (TECU) (تنها اگر کد گسل فعال است), سپس به گام 2.
[/fusion_content_box][fusion_content_box title=”گام 2. بررسی تعمیر.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- خارج از Key.
- دوباره به هم متصل تمام اتصالات و کابل منفی باتری.
- کلید در.
- کد پاک کردن, دیدن گسل غیر فعال روشن.
- رانندگی وسیله نقلیه و تلاش برای تنظیم مجدد کد.
- بررسی برای کدهای, دیدن نمایش گسل های فعال و غیر فعال.
- اگر هیچ کد, تست کامل شده است.
- اگر کد خطا 3 ظاهر می شود, پیدا کردن خطا در تست, رفتن به مرحله 1.
- اگر یک کد دیگر از 3 ظاهر می شود, دیدن گسل فهرست کد.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]