[fusion_builder_container hundred_percent=yeshundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Fejl kode 24 – J1939 HCM Message (TECU)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fejlkode for Eaton Hybrid Drive Systems modeller (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-cd, EH-8E306A-T, EH-6E606B-cd, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-cd, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-cd, EH-6E706B-P og EH-6E706B-UPG. The Unit Transmission Electronic Control (TECU) kommunikerer med Hybrid kontrolmodul (HCM) løbet linket J1939 data under køretøjets drift til at udveksle anmodet gear og aktuelle gear oplysninger.

fejlkode 24 – J1939 HCM Message (TECU) Opdagelse

Følgende forudsætninger skal være opfyldt, før systemet registrerer fejlen:

  • TECU tænding spænding er større end 7 volts og mindre end 16 volt.
  • No J1939 data link fault currently Active in the TECU.

Forhold til Set Fejlkode Aktiv

  • IMF 9 er indstillet, når TECU undlader at modtage transmission af data (såsom en anmodet gear) til 2 sekunder eller større fra HCM, og det er stadig at kommunikere med andre moduler på J1939.

Fallback Når Fejlkode 24 er indstillet følgende sker:

  • Rød ”Service” tændes,, og et ”F” blinker på gear display.
  • Fejl lagres i TECU hukommelse.
  • ændringer Operation Mode til Autoshift Fallback-tilstand.
  • Hvis fejlen indstiller ved opstart, motoren starter ikke.
  • Hvis fejlen sæt under kørsel, køretøjet befinder sig i nuværende gear. Når køretøjet standser koblingen åbner og forbliver i denne position.
  • Amber “Check Hybrid” light may display on the dash due to an Active fejlkode 48.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Forhold til Set Fejl kode inaktiv

Kun Inaktive fejl kan ryddes fra TECU eller HCM historie ved hjælp ServiceRanger. Den TECU rydder automatisk fejl fra historie efter 200 timer. Den HCM rydder automatisk en fejl fra historien, efter at den har været inaktiv i 200 timer.

Denne fejlkode kan være forårsaget af et af følgende:

  • IMF 9
    • J1939 Data Link
    • HCM

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

fejlkode 24 – J1939 HCM Message (TECU) Prøve

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Component Identifikation MY08 System:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14126|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Harness Set forfra TECU – Vehicle-interface” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Harness-Front-View-TECU.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness Set forfra
TECU – Vehicle-interface

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14061|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Harness Set forfra (HCM – Vehicle-interface)” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Fuller-Front-Harness-View-HCM.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Harness Set forfra
(HCM – Vehicle-interface)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

BEMÆRK: Der henvises til Eaton Hybrid Component og Connector Beliggenhed til Connector Steder i MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”25″ margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

BEMÆRK: Der henvises til Eaton Hybrid Component og Connector Beliggenhed til Connector Steder i MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14163|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Eaton Fuller TECU HCM-stik” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-TECU-HCM-connector-800×293.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”Advarsler & Forsigtig” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Fare: Fare angiver, at du vil blive alvorligt såret eller dræbt, hvis ikke følger den angivne procedure.
Advarsel: Advarsel angiver en umiddelbar fare, hvilket kan resultere i alvorlig personskade, hvis du ikke følger den angivne procedure.
Advarsel: Forsigtig angiver køretøj eller materiel skade kunne opstå, hvis du ikke følger den angivne procedure.

Bemærk: Bemærk indikerer yderligere detaljer, der vil hjælpe i diagnosticering eller reparation af en komponent / system.

Følg de angivne procedurer i den angivne rækkefølge for at undgå personskade:

1. Hvis højspændingsledninger kegler er omkring køretøjet og lockout er installeret på PEC, den eneste person, der skal have lov til at starte køretøjet er den person, der har underskrevet lockout tag.
2. Før der arbejdes på et køretøj eller forlade kabinen, mens motoren kører, du skal placere gearvælgeren i ”N” træk parkeringsbremsen, og blokere hjulene.
3. Af sikkerhedsmæssige årsager, altid i indgreb driftsbremserne forud for valg gearstillinger fra ”N.”
4. Før du starter et køretøj altid blive siddende i førersædet, Vælg ”N” på skift kontrol, og indstille parkeringsbremser.
5. I biler med ePTO, motoren og / eller
Motor / generator kan starte i ePTO tilstand. Aldrig udføre nogen form for vedligeholdelse eller arbejde på køretøj, mens i denne tilstand.
6. 12-Volt Batteri positiv (+) og negativ (-) skal frakobles forud for enhver svejsning på enhver Hybrid udstyrede køretøjs.

Advarsel: Følg de angivne procedurer i den angivne rækkefølge for at undgå fejlfunktion eller beskadigelse.
Advarsel: Slip ikke parkeringsbremsen eller forsøge at vælge et gear, indtil lufttrykket er på det korrekte niveau.
Advarsel: For at undgå beskadigelse af transmissionen under bugsering sted gearstangen i ”N” og løft drivhjulene fra jorden eller afbryde drivlinen.

Højspændingsledninger Advarsler & Forsigtig

  • Brug af CO2 eller pulver Brandslukkere.
  • Højspændingen ledninger er dækket i orange isolering eller indviklede slanger og mærket med advarselsskilte på stikkene.
  • Alle Eaton® Hybrid Diesel / Elektriske køretøjer vil blive markeret ’Hybrid’ på ydersiden af ​​køretøjet, sammen med skiftet etiket på instrumentbrættet.
  • Der henvises til OEM for specifikke placering af chassis monteret hybride komponenter.
  • Må ikke skåret i de orange højspændingskabler.
  • Må ikke skåret i eller åbne PEC.
  • Må ikke skåret i eller åbn DC / DC-konverter.
  • Må ikke skåret i eller åbn inverter.

En buffer zone skal oprettes og højspænding isolerede gummihandsker (klasse 0 med læder beskyttere) er påkrævet før arbejder på højspænding. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Gummi-isolerede handsker, der skal bæres under arbejdet på Højspændingsnettet er klasse 0 med læder beskyttere. De gummihandsker bør testes før hver brug følge proceduren gummi isolering handsker test findes i ”Diagnostiske Tools / Tjenesteydelser Publikationer” på side 6. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Før inspektion eller arbejder på eventuelle højspændingskabler eller komponenter ”High-Voltage service Nedlukning og Power-Up fremgangsmåde” på side 4 bør følges. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Lockout og Tagout enheder bør kun fjernes af teknikeren, der er tilføjet de Lockout og Tagout enheder på køretøjet. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Højspændingsledninger gummi isolerede handsker (klasse 0 med læder beskyttere) skal bæres, når der arbejdes på en hvilken som helst
højspændingsledninger. Den ”High-Voltage service Nedlukning og Power-Up fremgangsmåde” på side 4 skal følges før fjernelse af eventuelle højspændingsledninger. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Højspændingsledninger kabler og ledninger er orange og indeholde en advarsel på stikkene. Højspændingsdele er markeret med en etiket. Højspændingsledninger gummi isolerede handsker (klasse 0 med læder beskyttere) skal anvendes ved arbejde på enhver af disse komponenter. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.

Højspændingsledninger service Shutdown Procedurer

High-Voltage service Nedlukning og Power-Up Procedure1. Følg ”High-Voltage Arbejdsområdet” procedure.
2. Find den røde PEC service Tænd forsiden af ​​PEC og skub slukker.
3. Fjern Tjenesten Skift Cover og installere Lockout Bracket (J48506).
4. Fastgør tag til Lockout Bracket.
5. Sørg for PEC service switch kan ikke bevæge sig fra den slukket position.
6. Lad systemet til at sætte i mindst 5 minutter for at aflade højspænding.
7. Slut ServiceRanger og se data Monitor PID 116 kaldet ”High-Voltage Batteri Potential.” Brug SPN 520323 til J1939 forbindelse ”Batterispænding RB” (Relæ Box).
8. Spændingen skal være 30 volts eller mindre. Hvis spændingen er over 30 volt, virker ikke på køretøjet og kontakte Eaton® på 1-800-826-HELP (4357).
9. Drej tændingsnøglen ud og gå videre til at reparere eller fejlfinding.
Bemærk: Spændingen falder til nul, når nøglen er slukket.

High-Voltage service Power-Up Procedure

1. Installere alle højspænding stik i deres låste positioner.
2. Hvis du er den person, der arbejder på køretøjet, fjerne Lockout beslag og tag.
3. Geninstaller Lockout Bracket over service switch.
4. Træk Tjenesten Omlæg og lad bilen sæt til 2 minutter.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Component og Connector Beliggenhed ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent og Connector Steder MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Component og Connector Beliggenhed MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent og Connector Steder MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=TRIN 1. Check for Aktiv eller Inaktiv fejlkode status og udføre Elektrisk Pretest.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Hent Aktive fejlkoder og FMIs med ServiceRanger ved hjælp af 9-vejs Diagnostic Connector.
  2. Udfør elektrisk Pretest.
    • Hvis ingen problemer fundet under Electrical Pretest, gå til trin 2.
    • Hvis problemet blev repareret under Electrical Pretest, gå til trin 3.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=TRIN 2. Kontroller kontinuitet i bilens ledningsnet.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. nøgle slukket.
  2. Afbryd negative batterikabel.
  3. Disconnect HCM Vehicle Harness 38- vejs multistik.
  4. Measure resistance between HCM Vehicle Harness 38- Way Stik Ben 2 og Pin 3:
    Bemærk: Sørg for, at Volt / Ohm Meter er på rette skala (rundt om 200 ohm skala).

    • Hvis modstanden mellem Pin 2 og Pin 3 er mellem 50-70 ohm, erstatte den Hybrid kontrolmodul (HCM), derefter gå til trin 3.
    • Hvis modstanden er uden for rækkevidde, reparation J1939 Datalink Harness, derefter gå til trin 3.

[/fusion_content_box][fusion_content_box title=TRIN 3. Bekræft Reparationbackgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. nøgle slukket.
  2. Tilslut alle stik og negative batterikabel.
  3. nøgle på.
  4. klare koder, se Klare Inaktive fejl.
  5. Kør bilen og forsøger at nulstille koden.
  6. Kontroller for koder, se Se aktive og inaktive Fejl.
    • Hvis der ikke koder, testen er færdig.
    • Hvis fejlkode 24 kommer til syne, finde fejl i test, gå til trin 1.
    • Hvis en kode andet end 24 kommer til syne, se Fejl Kode Indeks Liste.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]