Hybrid Eaton Fuller Gudbinta Babaca Code 122 – APG CUTUB 1 Output

Khalad code for Hybrid Eaton daydo Systems Drive (MY08) Cuneyso-8E306A-U, Cuneyso-8E306A-UPG, Cuneyso-8E306A-UP, Cuneyso-8E306A-CD, Cuneyso-8E306A-T, Cuneyso-6E606B-CD, (MY09) Cuneyso-8E406A-U / P, Cuneyso-8E406A-UP, Cuneyso-8E406A-UPG, Cuneyso-8E406A-CD, Cuneyso-8E406A-CDG, Cuneyso-8E406A-guud, Cuneyso-8E406A-T, Cuneyso-6E706B-CD, Cuneyso-6E706B-P iyo aad cuneyso-6E706B-UPG. Read hoose si aad u bartaan sida si ay u tijaabiso, nadiifiso iyo hagaajin qalad code qalad aad Freightliner, Mack, Peterbilt, Kenworth, Volvo, International, iyo gaari xamuul culus-waajib iyo qalabka. The darran Power Generator (APG) waxaa a 5kW / 5kVA DC / AC Inverter xiran danab sare baska DC ee nidaamka gaariga Eaton Hybrid korontada. Waxaa abuuraa 60 -Hal waji 120V AC awood Hz ee codsiyada utility.

khalad Code 122 – APG CUTUB 1 Ogaanshaha Output

The shuruud soo socda waa in la buuxiyaa ka hor inta nidaamka ogaadaa gardarrada:

  • APG Inverter baahan yahay in la hawlgala.

Note: Marka dhib code ah Wax qabad la'aan tixraac ah Product Baarista Mode (PDM)

Xaaladaha in Calan Babaca Code Active

  • IMF 6 ayaa lagu wadaa markii badan ka badan dhacdooyinka hadda la ogaan.
  • IMF 14 ayaa lagu wadaa markii UPS ayaa la ogaado si aan caadi ahayn impedance yar yahay kaalinta ay wax soo saarka.
  • IMF 15 ayaa lagu wadaa markii UPS saarka xadka hadda (fakaray ama qiyaas) ayaa lagu dhaafo muddo ka badan uu oggol yahay xadka waqtiga gudaha.

Uugu Marka Babaca Code 122 ayaa lagu wadaa shuruudaha soo socda dhici:

  • Amber "Check Hybrid" illuminates light.
  • Gaf waxa lagu kaydiyaa Control Module Hybrid (Gudiga sare) xusuusta.
  • APG oo xiray.

Xaaladaha in Calan Babaca Code qabad la'aan

Kaliya unu qabad la'aan la nadiifiyay karaa Unit Gudbinta Electronic Control ah (TECU) ama taariikhda HCM isticmaalaya ServiceRanger. TECU ayaa si toos ah oo ansixiyay unu ka dib markii taariikhda 200 saacadood iyo HCM si toos ah oo ansixiyay unu ka soo taariikhda ka dib qalad uu Wax qabad la'aan, waayo, 200 saacadood.

code qalad Tani waxaa keeni kara wax ka mid ah kuwan soo socda:

  • IMF 6, 15
    • wajiga Short in dhulka uu xambaarka
    • qalabka wax soo saarka keenaya isxigxiga
    • Power Panel
    • APG
  • IMF 14
    • Qeybta barbaro hadda xad-dhaaf ah

khalad Code 122 – APG CUTUB 1 Imtixaanka Output

Aqoonsiga Qeybta:

APG 7-way High-Voltage AC Connector View

La habeeyo Front View
(Gudiga sare – Hybrid System Wajahadda isku xira)

APG 6-way Low-Voltage Connector View

Deutsch 4-jid isku xira OEM

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY08

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY09.

Qof kasta oo gudbinta qayb aad u baahan tahay aynu u leeyihiin! maalin isku mid ah maraakiibta la heli karo, dunida oo dhan.

U BAAHAN TAAGEERO FREE KA MID khubaro OUR?

WAC NOW
email US