Eaton Fuller Hybrid Fejl kode 6 – No HCM Operation

Fejlkode for Eaton Hybrid Drive Systems modeller (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-cd, EH-8E306A-T, EH-6E606B-cd, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-cd, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-cd, EH-6E706B-P og EH-6E706B-UPG. Hybrid kontrolmodul (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

fejlkode 6 – No HCM Operation Detection

Følgende forudsætninger skal være opfyldt, før systemet registrerer fejlen:

  • HCM tænding spænding er større end 7 volts og mindre end 16 volt.

Forhold til Set Fejlkode Aktiv

Forhold til Set Fejl:

  • IMF 12 is set at key on if the HCM detects an internal failure.
  • IMF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Når Fejlkode 6 er indstillet følgende sker:
• Amber ”Check Hybrid” tændes,.
• If the fault occurs at power up the vehicle may not crank.

Forhold til Set Fejl kode inaktiv

Kun Inaktive fejl kan ryddes fra Transmission Electronic Control Unit (TECU) eller HCM historik ved hjælp ServiceRanger. Den TECU rydder automatisk de fejl fra historie efter 200 timer. Den HCM rydder automatisk fejlene fra historien, efter at fejlen har været inaktiv i 200 timer.

Denne fejlkode kan være forårsaget af et af følgende:

  • IMF 12, 14
    • HCM

fejlkode 6 – No HCM Operation Test