Eaton Fuller Code Babaca Hybrid 5 Motor Generator AC Cable

Khalad code for Hybrid Eaton daydo Systems Drive (MY08) Cuneyso-8E306A-U, Cuneyso-8E306A-UPG, Cuneyso-8E306A-UP, Cuneyso-8E306A-CD, Cuneyso-8E306A-T, Cuneyso-6E606B-CD, (MY09) Cuneyso-8E406A-U / P, Cuneyso-8E406A-UP, Cuneyso-8E406A-UPG, Cuneyso-8E406A-CD, Cuneyso-8E406A-CDG, Cuneyso-8E406A-guud, Cuneyso-8E406A-T, Cuneyso-6E706B-CD, Cuneyso-6E706B-P iyo aad cuneyso-6E706B-UPG. The Motor/Generator AC Cables are connected from the Motor/Generator to the Inverter. These cables carry up to 500 volts AC 3 wajiga markii gaariga uu yahay hawlgal.

khalad Code 5 Motor / Generator AC Cable Ogaanshaha

  • danab Inverters suuroggalaan waa ka weyn yahay 7 volts iyo ka yar 16 volts.
  • FMI 25-27 baahan RPM Motor / Generator in ay ka weyn tahay 500 RPM.
  • IMF 28 waxay u baahan tahay RPM Motor / Generator in ay ka yar tahay 500 RPM.
  • IMF 29 waxay u baahan tahay RPM Motor / Generator in ay ka yar tahay 50 RPM.

Xaaladaha in Calan Babaca Code Active

Xaaladaha in Calan Babaca Code:

  • IMF 21: Calan markii Bannaanka interlock AC furan yahay.
  • IMF 22, 23, 24 ayaa lagu wadaa markii 2-waji motor hadda waa ka badan 360 amps waayo, 0.9 MS.
  • IMF 25, 26, 27 ayaa lagu wadaa markii Inverter ku ogaadaa silig hal furan iyo motor hadda ka yar tahay 8 amps waayo, 200 MS xawaare ka weyn ama loo siman yahay si 500 RPM iyo amarka hadda ka Inverter ka wada weyn yahay 20 amps.
  • IMF 28 ayaa lagu wadaa markii Motor / Generator hadda ka yar tahay 8 amps waayo, 200 MS xawaare ka yar 500 RPM iyo amarka hadda waa ka sii badan 20 amps.
  • IMF 29 ayaa lagu wadaa inta lagu guda jiro initialization. Inverter ayaa go'aamisa haddii AC Cable ku xiran yahay dhexeeya motor iyo Inverter by diraya baxay 20 amps waayo, 200 MS iyo hubinta feedback.

Uugu Marka Babaca Code 5 ayaa lagu wadaa shuruudaha soo socda dhici:

  • Red "Stop Hybrid" illuminates light.
  • Gaf waxa lagu kaydiyaa Control Module Hybrid (Gudiga sare) xusuusta.
  • Inverter xidho nidaamka a high-voltage off.
  • Gudiga sii si loo xakameeyo gaariga hybrid ah in hab naaftada kaliya.
  • Haddii FMI 28, ama 29 joogo ilaa xoog, gaariga ma kumbyuutarradeedu.

Xaaladaha in Calan Babaca Code qabad la'aan

Kaliya unu qabad la'aan la nadiifiyay karaa Unit Gudbinta Electronic Control ah (TECU) ama taariikhda HCM isticmaalaya ServiceRanger. TECU ayaa si toos ah oo ansixiyay unu ka dib markii taariikhda 200 saacadood. Gudiga ayaa si toos ah oo ansixiyay unu ka taariikh ka dib markii code qalad uu Wax qabad la'aan, waayo, 200 saacadood.

code qalad Tani waxaa keeni kara wax ka mid ah kuwan soo socda:

  • IMF 21
    • AC Cable Interlock
  • IMF 22, 23, 24
    • Inverter
    • Motor / Generator
    • AC cable
  • IMF 25, 26, 27, 28, 29
    • Motor / Generator
    • AC Cable

khalad Code 5 – Motor / Generator Test AC Cable

System Qeybta Aqoonsiga MY08:

High-Voltage AC Harness Connector View

High-danab AC la habeeyo isku xira View
(Amphenol isku xira)

High-Voltage AC Motor/Gen Connector View

High-danab AC Motor / Gen isku xira View
(Amphenol isku xira)

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY08

hybrid component connector

System Qeybta Aqoonsiga MY09:

High-Voltage AC Harness Connector View

High-danab AC la habeeyo isku xira View
(Amphenol isku xira)

High-Voltage AC Motor/Gen Connector View

High-danab AC Motor / Gen isku xira View
(Amphenol isku xira)

FIIRO GAAR AH: U dir ka Eaton Qeybta Hybrid oo isku xira Location waayo, Goobaha isku xira in Systems MY09.

hybrid component connector

Qof kasta oo gudbinta qayb aad u baahan tahay aynu u leeyihiin! maalin isku mid ah maraakiibta la heli karo, dunida oo dhan.

U BAAHAN TAAGEERO FREE KA MID khubaro OUR?

WAC NOW
email US