[fusion_builder_container hundred_percent=yeshundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Fejl kode 1 Motor Generator Current Sensor

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Fejlkode for Eaton Hybrid Drive Systems modeller (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-cd, EH-8E306A-T, EH-6E606B-cd, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-cd, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-cd, EH-6E706B-P og EH-6E706B-UPG. The High-Voltage Motor/Generator Assembly is connected to the Inverter Assembly through an AC High-Voltage Cable that contains 3 separate kabler. Under drift, the Inverter monitors the amperage in the AC cables through a current sensor, som er monteret inden inverteren. The inductive sensor produces an output based on amperage present in the cables.

fejlkode 1 Motor / generator Current Sensor Detection

Den Inverter tænding spænding er større end 7 volts og mindre end 16 volt.

Forhold til Set Fejlkode Aktiv

Forhold til Set Fejl:

  • IMF 6 is set when Inverter detects current input from the Motor/Generator greater than 100 ampere for 150 FRK.
  • IMF 0 is set when the Inverter detects current input from the Motor/Generator greater than 200 ampere for 0.3 FRK.
  • IMF 15 is set when the sensor offset is out of range at initial check.

Fallback Når Fejlkode 1 er indstillet følgende sker:
• Amber ”Check Hybrid” tændes,.
• Fejl gemmes i Hybrid Control Module (HCM) hukommelse.
• Electric Motor/Generator Assist and Regeneration are disabled; imidlertid, højspændingsledninger relæer forbliver strømforsynet.
• HCM continues to control the hybrid vehicle in a diesel-only mode.
• Transmission defaults starte gear til 1st.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Forhold til Set Fejl kode inaktiv

Kun Inaktive fejl kan ryddes fra Transmission Electronic Control Unit (TECU) eller HCM historik ved hjælp ServiceRanger. Den TECU rydder automatisk de fejl fra historie efter 200 hours and the HCM automatically clears the faults from history after the fault has stayed Inactive for 200 timer.

Denne fejlkode kan være forårsaget af et af følgende:

  • IMF 0, 6
    • Inverter
    • Motor / generator
    • AC-kabel
  • IMF 15
    • Inverter

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

fejlkode 1 – Motor / generator Current Sensor Test

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Component Identifikation MY08 System:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”13902|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”High-Voltage AC Harness Connector Se” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Harness-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

High-Voltage AC Harness Connector Se
(Amphenol stik)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”13903|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”High-Voltage AC motor / Gen Connector Se ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Motor-Gen-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

High-Voltage AC motor / Gen Connector Se
(Amphenol stik)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”10″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

BEMÆRK: Der henvises til Eaton Hybrid Component og Connector Beliggenhed til Connector Steder i MY08 Systems

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”13904|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”komponent-stik” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/eaton-component-connector-800×380.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Component Identifikation MY09 System:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”13902|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”High-Voltage AC Harness Connector Se” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Harness-Connector-View.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

High-Voltage AC Harness Connector Se
(Amphenol stik)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14034|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”High-Voltage AC motor / Gen Connector Se ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/High-Voltage-AC-Motor-Gen-Connector-View-MY09.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

High-Voltage AC motor / Gen Connector Se
(Amphenol stik)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”10″ animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

BEMÆRK: Der henvises til Eaton Hybrid Component og Connector Beliggenhed til Connector Steder i MY09 Systems.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”13904|800″ max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=nonebordersize=”” bordercolor=”” borderradius=”” align=centerlightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”komponent-stik” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/eaton-component-connector-800×380.jpg[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”Advarsler & Forsigtig” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]

Fare: Fare angiver, at du vil blive alvorligt såret eller dræbt, hvis ikke følger den angivne procedure.
Advarsel: Advarsel angiver en umiddelbar fare, hvilket kan resultere i alvorlig personskade, hvis du ikke følger den angivne procedure.
Advarsel: Forsigtig angiver køretøj eller materiel skade kunne opstå, hvis du ikke følger den angivne procedure.

Bemærk: Bemærk indikerer yderligere detaljer, der vil hjælpe i diagnosticering eller reparation af en komponent / system.

Følg de angivne procedurer i den angivne rækkefølge for at undgå personskade:

1. Hvis højspændingsledninger kegler er omkring køretøjet og lockout er installeret på PEC, den eneste person, der skal have lov til at starte køretøjet er den person, der har underskrevet lockout tag.
2. Før der arbejdes på et køretøj eller forlade kabinen, mens motoren kører, du skal placere gearvælgeren i ”N” træk parkeringsbremsen, og blokere hjulene.
3. Af sikkerhedsmæssige årsager, altid i indgreb driftsbremserne forud for valg gearstillinger fra ”N.”
4. Før du starter et køretøj altid blive siddende i førersædet, Vælg ”N” på skift kontrol, og indstille parkeringsbremser.
5. I biler med ePTO, motoren og / eller
Motor / generator kan starte i ePTO tilstand. Aldrig udføre nogen form for vedligeholdelse eller arbejde på køretøj, mens i denne tilstand.
6. 12-Volt Batteri positiv (+) og negativ (-) skal frakobles forud for enhver svejsning på enhver Hybrid udstyrede køretøjs.

Advarsel: Følg de angivne procedurer i den angivne rækkefølge for at undgå fejlfunktion eller beskadigelse.
Advarsel: Slip ikke parkeringsbremsen eller forsøge at vælge et gear, indtil lufttrykket er på det korrekte niveau.
Advarsel: For at undgå beskadigelse af transmissionen under bugsering sted gearstangen i ”N” og løft drivhjulene fra jorden eller afbryde drivlinen.

Højspændingsledninger Advarsler & Forsigtig

  • Brug af CO2 eller pulver Brandslukkere.
  • Højspændingen ledninger er dækket i orange isolering eller indviklede slanger og mærket med advarselsskilte på stikkene.
  • Alle Eaton® Hybrid Diesel / Elektriske køretøjer vil blive markeret ’Hybrid’ på ydersiden af ​​køretøjet, sammen med skiftet etiket på instrumentbrættet.
  • Der henvises til OEM for specifikke placering af chassis monteret hybride komponenter.
  • Må ikke skåret i de orange højspændingskabler.
  • Må ikke skåret i eller åbne PEC.
  • Må ikke skåret i eller åbn DC / DC-konverter.
  • Må ikke skåret i eller åbn inverter.

En buffer zone skal oprettes og højspænding isolerede gummihandsker (klasse 0 med læder beskyttere) er påkrævet før arbejder på højspænding. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Gummi-isolerede handsker, der skal bæres under arbejdet på Højspændingsnettet er klasse 0 med læder beskyttere. De gummihandsker bør testes før hver brug følge proceduren gummi isolering handsker test findes i ”Diagnostiske Tools / Tjenesteydelser Publikationer” på side 6. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Før inspektion eller arbejder på eventuelle højspændingskabler eller komponenter ”High-Voltage service Nedlukning og Power-Up fremgangsmåde” på side 4 bør følges. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Lockout og Tagout enheder bør kun fjernes af teknikeren, der er tilføjet de Lockout og Tagout enheder på køretøjet. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Højspændingsledninger gummi isolerede handsker (klasse 0 med læder beskyttere) skal bæres, når der arbejdes på en hvilken som helst
højspændingsledninger. Den ”High-Voltage service Nedlukning og Power-Up fremgangsmåde” på side 4 skal følges før fjernelse af eventuelle højspændingsledninger. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.
Højspændingsledninger kabler og ledninger er orange og indeholde en advarsel på stikkene. Højspændingsdele er markeret med en etiket. Højspændingsledninger gummi isolerede handsker (klasse 0 med læder beskyttere) skal anvendes ved arbejde på enhver af disse komponenter. Manglende overholdelse af disse instruktioner kan medføre alvorlig personskade eller død.

Højspændingsledninger service Shutdown Procedurer

High-Voltage service Nedlukning og Power-Up Procedure1. Følg ”High-Voltage Arbejdsområdet” procedure.
2. Find den røde PEC service Tænd forsiden af ​​PEC og skub slukker.
3. Fjern Tjenesten Skift Cover og installere Lockout Bracket (J48506).
4. Fastgør tag til Lockout Bracket.
5. Sørg for PEC service switch kan ikke bevæge sig fra den slukket position.
6. Lad systemet til at sætte i mindst 5 minutter for at aflade højspænding.
7. Slut ServiceRanger og se data Monitor PID 116 kaldet ”High-Voltage Batteri Potential.” Brug SPN 520323 til J1939 forbindelse ”Batterispænding RB” (Relæ Box).
8. Spændingen skal være 30 volts eller mindre. Hvis spændingen er over 30 volt, virker ikke på køretøjet og kontakte Eaton® på 1-800-826-HELP (4357).
9. Drej tændingsnøglen ud og gå videre til at reparere eller fejlfinding.
Bemærk: Spændingen falder til nul, når nøglen er slukket.

High-Voltage service Power-Up Procedure

1. Installere alle højspænding stik i deres låste positioner.
2. Hvis du er den person, der arbejder på køretøjet, fjerne Lockout beslag og tag.
3. Geninstaller Lockout Bracket over service switch.
4. Træk Tjenesten Omlæg og lad bilen sæt til 2 minutter.
5. Start bilen når det er passende.

[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Hybrid Component og Connector Beliggenhed ” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent og Connector Steder MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Hybrid Component og Connector Beliggenhed MY09 Systems” size=largebackground=”#ffffffborder_color=”” show_footer=yesclass=”” id=””]

Eaton Hybrid Komponent og Connector Steder MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=no-repeatfade=nobackground_parallax=noneenable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=no-repeathover_type=noneborder_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”1″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” image_max_width=””][fusion_content_box title=TRIN 1. Check for fejlkode status og kontinuitet i højspændingsledninger kredsløb.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Gennemgå og følg Advarsler & Forsigtig.
  2. Hent Aktive fejlkoder og FMIs med ServiceRanger ved hjælp af 9-vejs Diagnostic Connector.
  3. nøgle slukket.
    Fare: Se High-Voltage service Nedlukning og power-up procedurer. Følg procedurerne for at undgå chok, brænde eller død fra forkert håndteret højspænding.
  4. Remove the AC Cable from the Motor/Generator and Inverter.
  5. Measure resistance of each circuit in the AC High-Voltage Cable Pins A-A, B-B og C-C:
    • If resistance for each circuit is less than 1 ohm, gå til trin 2.
    • Hvis modstanden er uden for rækkevidde, erstatte AC højspændingsledning, derefter gå til trin 5.
    • Hvis FMI 15 er Aktiv, erstatte Inverter.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” image_max_width=””][fusion_content_box title=TRIN 2. Kontrollere kontinuiteten i højspændingskredsløb til jord.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Measure resistance of each circuit to ground in the AC High-Voltage Cable:
    • If resistance between each circuit and ground is 5M ohms or greater, gå til trin 3.
    • Hvis modstanden er uden for rækkevidde, erstatte AC højspændingsledning, derefter gå til trin 5.

[/fusion_content_box][fusion_content_box title=TRIN 3. Kontrollere kontinuiteten i højspændingskredsløb.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. nøgle slukket
  2. Measure the resistance between the following AC High-Voltage Cable Pins A-B, B-C og C-A(MY08 Systems) A-A, B-B, C-C (MY09 Systems):
    • Hvis modstanden af ​​hver fase er 5M eller større, gå til trin 4.
    • Hvis modstanden er uden for rækkevidde, erstatte AC højspændingsledning, derefter gå til trin 5.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18pxheading_size=”3″ title_color=”#ffffffbody_color=”#ffffffbackgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_max_width=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=leftanimation_type=”” animation_delay=”” animation_offset=”” animation_direction=leftanimation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=TRIN 4. Kontrollere kontinuiteten i Motor / Generator faser.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” image_height=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. Measure resistance of each Motor/Generator phase at the following Pins: A-B, B-C og C-A (MY08 Systems) / A-A, B-B, C-C (MY09 Systems):
    • If resistance of each phase is less than 10 ohm, erstatte Inverter, derefter gå til trin 5.
    • Hvis modstanden er uden for rækkevidde, erstatte Motor / generator, derefter gå til trin 5.

[/fusion_content_box][fusion_content_box title=TRIN 5. Bekræft reparation.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_max_width=”” link=”” linktext=”Læs mere” link_target=”” animation_type=”” animation_direction=leftanimation_speed=”0.3″ animation_offset=””]

  1. nøgle slukket
  2. Tilslut alle stik og den negative batterikabel.
  3. nøgle på
  4. klare koder
  5. Kør bilen og forsøger at nulstille koden.
  6. Kontroller for koder. Hvis der ikke koder, testen er færdig, Hvis Fejlkode 1 kommer til syne, finde fejl i test, gå til trin 1. Hvis en ny kode vises, se Fejl Kode Indeks Liste.