[fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Eaton Fuller Hybrid Code Fault nifşek 116 – Fault Voltage Relays High – (sîstemên MY09)

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Qusûra code for Eaton Hybrid modelên Drive Systems (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P û EH-6E706B-UPG. Read li jêr hîn bibin ku çawa ji bo ceribandinê, paqij û sererast çewtî code sûcê bo Freightliner te, Mack, Peterbilt, Kenworth, Volvo, Navnetewî, û truck giran-erkê û alavên. The Relays High-Voltage bi nava Power located
Electronics Carrier (PEC) di beşa Relay Box. There is one Pre-Charge Relay on the positive side, an Ferzê din li ser erênî, and on the negative for a total of three relays. Ev peyamstînerî di normalê de vekirî dema sîstema off e. The peyamstînerî bi rêya bibîne bin kontrola.

qusûra Code 116 – Detection Voltage High Relays Fault

The mercên li jêr, divê bên pêşwazîkirin li ber sîstema yê li şaşî bibîneûdi:

  • voltaja dadana bibîne mezintir e 7 volt û kêmtir ji 16 volts.

Not: Dema serastkirinê an code Neçalak bitikînin Product Mode Diagnostic (PDM)

Şert û mercên ji bo Set Code Fault Active

  • IMF 3 Biryar e ku dema kurt de ji bo 12 volts li ser aliyê kontrola a Ferzê bilind-voltaja Seûdiyê.
  • IMF 4 Biryar e ku dema kurt de ji erdê ye, li aliyê kontrola a Ferzê bilind-voltaja Seûdiyê.
  • IMF 5 û FMI 10 bi set dema ku circuit vekirî ye ku li aliyê kontrola a Ferzê bilind-voltaja Seûdiyê.
  • IMF 7 û FMI 14 bi set dema ku Ferzê sereke yên neyînî li ser e û li bibîne decrease voltaja capacitor kêmtir ji 10-volts e / 5 seconds dema voltaja capacitor destpêkê mezintir bû 200 volts.

Dih Dema Code Fault 116 Biryar e ku şert û mercên li jêr pêk:

  • Amber "Check Hybrid" ronîkirin ronahî.
  • Fault di Modula Kontrola Hybrid profîlek (HCM) bîr.
  • Sîstema hybrid offline dê bibe.
  • Transmission defaults start gear to 1st in diesel-only mode.

[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Şert û mercên ji bo Set Fault Code Neçalak

Tenê kêmasîyên neçalak dikare ji dîroka TECU an HCM bikaranîna ServiceRanger kenîştê. The TECU automatically kiribin gonehên ji dîroka piştî 200 saetan. The HCM automatically gehîştî a sûcê ji dîroka piştî ku sûcê hatiye çalake 200 saetan.

Ev koda sûcê dikare ji aliyê yek ji yên jêr ji ber:

  • IMF 3, 4, 5, 7, 10, 14
    • Voltage wire Feedback ji mêjûya DC / DC ji bo HCM
  • IMF 4
    • Box Relay
    • Switch Inertia
    • bibîne
    • Harness Wiring Vehicle di navbera bibîne û PEC
    • Main High-Voltage Service Fuse belavbûyî an wenda
    • DC High-Voltage Cable Interlock
    • PEC Button Red Switch Service

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

qusûra Code 116 – Voltage High Relays Test Fault

[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Diyarkirina Component:

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14476|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”netû” bordersize=”” bordercolor=”” borderradius=”” align=”navîne” lightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40-way connector mating view bibîne connector kêm-voltaja” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Duetsch 40-way view connector mating
(Bibîne connector kêm-voltaja)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2layout=”1_2spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14213|mediummax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”netû” bordersize=”” bordercolor=”” borderradius=”” align=”navîne” lightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Mating view connector Deutsch 19-way ” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

Mating view connector
(Deutsch connector 19-way)

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=left topundefined=”” background_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=defaultrule_size=”” rule_color=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””]

NOT: Bi xweşî hatî ferhenga Refer Eaton Component Hybrid û Connector Location ji bo Locations Connector li Systems MY09.

[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_imageframe image_id=”14672|fullmax_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”netû” bordersize=”” bordercolor=”” borderradius=”” align=”navîne” lightbox=nogallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Bibîne ji bo PEC MY09 Systems” link=”” linktarget=_selfhide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_modal name=warnings_cautionstitle=”Hişyarî & kirêt” size=largebackground=”” border_color=”” show_footer=yesclass=”” id=””]Talûke: Danger nîşan dide ku tu dê bi giranî birîndar bûn an jî hatin kuştin, eger hûn prosedûra got pey.
Gazî: Hişyarî nîşan dide ku xeternak yekser, ku dikarin zerar giran şexsî encama eger hûn prosedûra got pey.
Baldaynî: Ji tera nîşan dide wesayîta an zerar dikare biqewime, eger tu prosedûra got pey.

Not: Têbînî nîşan dide detail din ku di nasîna an repair of a component / sîstema hawara wê.

Follow prosedurên de hatine diyarkirin di da Odîerno, ji bo birînên şexsî:

1. Eger cones bilind-voltaja li dora erebeyê ne û di beşîktaşê li ser PEC sazkirin, de tenê kesek ku divê lê bê destûr da ku dest bi wesayîta kesê ku tag lockout îmze e.
2. Berî ku kar li ser wesayîta an dev ji cab dema ku engine bardike, divê tu lever guherîna "N" danîn şikand parkkirinê de, û astengkirina wheels.
3. Ji ber sedemên ewlehiyê, her tim teşebusên brakes xizmeta berî hilbijartina çeperên gear ji "N."
4. Li ber dest wesayîta her tim li ser kursiyê ajokeran rûniştî were, hilbijêre "N" li ser kontrol Shift, û set brakes parkkirinê de.
5. Di wesayîtên bi ePTO, engine û / an
Motor / Generator nikare di moda ePTO dest. Qet tu maintenance pêkanîna an jî kar li ser wesayîta, dema li ser vî awayê.
6. 12-Volt Battery erênî (+) û neyînî (-) Divê berî her welding li ser ti wesayîta Hybrid stendine didît bê.

Baldaynî: Follow prosedurên de hatine diyarkirin di da Odîerno, ji bo alavên xira an jî ziyan.
Baldaynî: Ma şikand parkkirinê berdim ne an hewldana ji bo hilbijêre a gear, heta ku hewa tekeran e li ser astê correct.
Baldaynî: To rê li xerabûna veguhestina di dema tora cihê lever guherîna ku di "N" û rakirina wheels ajogera off erdê an de nakokî li driveline.

Hişyarî High-Voltage & kirêt

  • Use CO2 an Dry Kîmyewî Alavên vemirandinê.
  • Li wiring bilind-voltaja di insulasyona orange an tubing convoluted nixamt û mohra xwe bi heşyar li connectors.
  • Hemû Eaton® Hybrid Diesel / wesayîtên Electric bên nîşankirin, dê 'Hybrid’ li derve ji wesayîta, gel yên ku bi label guherîna li ser dash.
  • ji bo cihê taybetî yên disotîne siyar pêkhateyên hybrid bo OEM Refer.
  • Do NOT nav orange kabloyên bilind-voltaja birrîn.
  • Ma nav birrîn û ne jî krdineweyi PEC.
  • Ma nav birrîn û ne jî krdineweyi mêjûya DC / DC.
  • Ma nav birrîn û ne jî krdineweyi bibîne.

A herêma tampon bên damezrandin û bilind-voltaja lepikên xwe yên plastîk îzolekirî (sinif 0 bi kirasê parêzvaniya leather) bi ji kar li ser bilind-voltaja berî pêwîst. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.
Lepikên-plastîk îzolekirî ku divê li dema kar li ser sîstema bilind-voltaja lixwekirin in class 0 bi kirasê parêzvaniya leather. Lepikên ji plastîk, divê berî her bikaranîna jêr prosedûra plastîk lepikan insulasyona di "Amûr Diagnostic / Bilawkirawekan Service" li ser tê dîtin, ceribandin 6. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.
Berî ku kevnî an jî kar li ser ti kabloyên bilind-voltaja an niyaza "High-Voltage Girtin Service û Power-Up CMK'ê" li ser rûpela 4 divê bê şopandin. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.
Cîhazan de beşîktaşê û Tagout tenê divê bi destê teknîsyenekî ku cîhazên beşîktaşê û Tagout li ser wesayîta danîn rakirin. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.
High-voltaja plastîk îzolekirî lepikên (sinif 0 bi kirasê parêzvaniya leather) divê di dema xebatê de li ser her lixwekirin
kabloyên bilind-voltaja. "Êde High-Voltage Service û Power-Up CMK'ê" li ser rûpela 4 divê berî veqetiyan kabloyên bilind-voltaja were şopandin. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.
kabloyên High-voltaja û wiring orange in û nahundirîne label hişyariyê li connectors. pêkhateyên High-voltaja bi bi label nîşankirin. High-voltaja plastîk îzolekirî lepikên (sinif 0 bi kirasê parêzvaniya leather) divê di dema xebatê de li ser yek ji van pêkhateyên bên bikaranîn. Têkçû li pey van talîmatên dikarin di birînên şexsî giran an encama mirinê.

High-Voltage Rûtînên Girtin Service

High-Voltage Girtin Service û Power-Up CMK'ê1. Follow "High-Voltage Area Work" pêvajoya kirarî.
2. Locate sor Switch PEC Service li ber PEC û push elektrîkî.
3. Jê de Cover Service Switch û saz Bracket beşîktaşê de (J48506).
4. tag aţitî ji beşîktaşê Bracket.
5. Misogerkirina Switch PEC Service ne dikarin ji rewşa off bar.
6. Destûrê bide ku sîstema ji bo danîna ji bo herî kêm 5 deqeyan ji bo xizmeta voltaja bilind.
7. Girêdana ServiceRanger û dîtina Data Monitor PID 116 bi navê "Potential Battery High-Voltage." Use SPN 520323 ji bo girêdanê J1939 "Pîlê Voltage RB" (Box Relay).
8. The voltaja divê bibin 30 volt an kêmtir. Eger voltaja jor e 30 volts, Ma li ser wesayîteke kar ne û li gel Eaton® li 1-800-826-ALÎKARÎ (4357).
9. Turn key dadana off û berdewamiyê ji bo temîrkirina an gav troubleshooting.
Not: The voltaja drops bo zero dema key off e.

High-Voltage Service Power-Up CMK'ê

1. Install hemû connectors bilind-voltaja nav çeperên girtin [Girtî] xwe.
2. Eger tu kesê kar li ser wesayîta, jê di beşîktaşê Bracket û tag.
3. Nûsazkirina di beşîktaşê Bracket ser Switch Xizmeta ji.
4. Kolane, Dezgeha Switch derket û bila set wesayîta ji bo 2 minutes.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=component_locationtitle=”Eaton Component Hybrid û Connector Location ” size=largebackground=”#ffffff” border_color=”” show_footer=yesclass=”” id=””]

Eaton Component Hybrid û Locations Connector MY08 Systems

[/fusion_modal][fusion_modal name=component_location2title=”Eaton Component Hybrid û Connector Location MY09 Systems” size=largebackground=”#ffffff” border_color=”” show_footer=yesclass=”” id=””]

Eaton Component Hybrid û Locations Connector MY09 Systems

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=nohundred_percent_height=nohundred_percent_height_scroll=nohundred_percent_height_center_content=yesequal_height_columns=nomenu_anchor=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilitystatus=publishedpublish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=center centerbackground_repeat=”no-repeat” fade=nobackground_parallax=”netû” enable_mobile=noparallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=yesvideo_mute=yesvideo_preview_image=”” border_size=”” border_color=”” border_style=solidmargin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1layout=”1_1spacing=”” center_content=nolink=”” target=_selfmin_height=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=left topbackground_repeat=”no-repeat” hover_type=”netû” border_size=”0″ border_color=”” border_style=solidborder_position=allpadding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=”” last=no”][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=Step 1.Verify FMIs niha.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. Review û li pey Hişyarî & kirêt.
  2. Şûnde codes sûcê Têketina û FMIs bi ServiceRanger bikaranîna 9-Way Diagnostic Connector.
  3. bikaranîna ServiceRanger, bi xwendina record di "Monitor Data" di bin Battery J1939 Data HV: parametreyê 520250 voltaja potansiyela HV Battery1 û parametre 520323 Pîlê Voltage RB. Watch voltaja li RB Voltaja Pîlê dema key ser û gavên voltaja record Eger tu amade ne.
  4. Kîjan FMIs amade ne?
    • Ger Code Fault 116 IMF 3 di lîsteyê de ye, biçe Step 2.
    • Ger Code Fault 116 IMF 4 di lîsteyê de ye, biçe Step 4.
    • Ger Code Fault 116 IMF 5 an 10 di lîsteyê de ye, biçe Step 6.
    • Ger Code Fault 116 IMF 7 di lîsteyê de ye, biçe Step 13.

[/fusion_content_box][fusion_content_box title=GAV 2. Piştrastkirina repair.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key, payin 1 deqqe.
  2. Bibire 40-Way bibîne Connector.
  3. Key li ser (ev dê Code Fault danîn 88, sûcê zelal piştî bi çakkirina).
  4. Li ser Vehicle Harness, ji bo tu voltaja li ser pin kontrol 21, 31, 22, 32, 23 û 33 ji erdê:
    • Ger tu voltaja ye, hatiye dîtin, jê 19-Way Connector li ser PEC û vevêre bo voltaja li bibîne 40-Pin, paşê biçe Step 3.
    • Ger voltaja e hîn jî amade, Vehicle repair di navbera bibîne û li 40-Pin, paşê biçe Step 3.
    • Ger voltaja gone e, biçe Step 3

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 3. Piştrastkirina berdewamiya circuits Connector PEC ji bo qirçandin.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. 1. off Key.
    2. Bibire bi navê PEC 19-Way Connector (red Service Switch hê jî divê vekişiyaye bê).
    3. Bipîvin berxwedana li ser termînalan 19-Way Connector jêr:

    • Derzî 9 ji bo Pin 6 û pin 9 ji bo Pin 12
    • Derzî 13 ji bo Pin 6 û pin 13 ji bo Pin 12
    • Derzî 17 ji bo Pin 6 û pin 17 ji bo Pin 12
      • Ger circuit vekirî, biçe Step 2.
      • Ger tu berxwedanê tê dîtin, li şûna Box Relay, paşê biçe Step 14.

[/fusion_content_box][fusion_content_box title=GAV 4. Piştrastkirina berdewamiya circuits bibîne Connector.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. Bibire li bibîne 40-Way Connector (19-Connector Way li PEC divê bi Switch Service sor girêdayî zêrek derxist).
  3. Li ser Vehicle Harness, ji bo berxwedana li erdê li ser pin kontrol 21 ji erdê, Derzî 22 ji bo erdê û pin 23 ji erdê:
    • Ger tu berxwedana ji Connectors bibîne ji erdê ye, hatiye dîtin, qût PEC 19-Way Connector û vevêre li OEM 40-Way Connector.
    • Heke berxwedana hîn jî bi 19-Way dîtin didît û, telafîkirina Harness Vehicle, paşê biçe Step 14.
    • Ger ku berxwedana bi 19-Way derbas didît û, biçe Step 5.
    • Ger metre xwendin OL an Open Circuit, li şûna bibîne, paşê biçe Step 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 5. Piştrastkirina berdewamiya circuits Connector PEC ji bo qirçandin.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. Bibire bi navê PEC 19-Way Connector.
  3. Li ser navê PEC 19-Way Connector, pîvan:
    • Derzî 9, Derzî 13 û pin 17 ji erdê
    • Derzî 9 ji bo Pin 7, Derzî 9 ji bo Pin 10, Derzî 9 ji bo PEC Mounting Stud
    • Derzî 13 ji bo Pin 7, Derzî 13 ji bo Pin 14, Derzî 13 ji bo PEC Mounting Stud
    • Derzî 17 ji bo Pin 7, Derzî 17 ji bo Pin 14, Derzî 17 ji bo PEC Mounting Stud
      • Ger tu berxwedana ji Pin PEC dîtin ji bo qirçandin, li şûna Box Relay. Binêre li Waxing MY09 PEC High-Voltage Relay Box û prosedura Installation li TRSM2000, paşê biçe Step 14.
      • Ger metre xwendin OL, retesting pêwîst e, biçe Step 4.

[/fusion_content_box][fusion_content_box title=GAV 6. Piştrastkirina berdewamiya circuits Connector PEC.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. Bibire bi navê PEC 19-Way Connector. (Button Service Sor li PEC divê zêrek derxist.)(Ma "CMK'ê Girtin Hybrid" pêkanîna ne yet.)
  3. Bipîvin berxwedana li ser PEC Connector:
    • Derzî 9 ji bo Pin 11
    • Derzî 13 ji bo Pin 15
    • Derzî 17 ji bo Pin 19
      • Ger ku berxwedana di navbera Pin 9 û pin 11, û pin 13 ji bo Pin 15 her 33-37 Ohms û berxwedana ji pin in 17 ji bo Pin 19 112-122 Ohms e, biçe Step 7.
      • Ger tu berxwedana e li derveyî range, reset Switch Inertia dikeve hundir vekirina Parzûna hewa an li Rear Access Panel ji aliyê High-Voltage Fuse, paşê biçe Step 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 7. Kontrol bilind-voltaja Interlock cable li ser Cable OEM.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. Piştrastkirina ku Switch Inertia OK e.
  2. Bipîvin berxwedana Pin Interlock li ser Cable OEM.
    Talûke: Dîtin High-Voltage Girtin Service û Power-Up Rûtînên. Follow prosedurên ji dûr şokê, bişewitin an mirinê ji çewt bidome bilind-voltaja.

    • Heke berxwedana 0-0.3 Ohms e, li şûna Box Relay, paşê biçe Step 9.
    • Heke berxwedana OL e, li şûna Cable High-Voltage DC, paşê biçe Step 8.

[/fusion_content_box][fusion_content_box title=GAV 8. Piştrastkirina berdewamiya circuits Connector PEC ji bo qirçandin.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. Bipîvin berxwedana li ser PEC Connector (red Switch Button Service ye derxist):
    • Derzî 9 ji bo Pin 11
    • Derzî 17 ji bo Pin 19
      • Ger tu berxwedana OL e, li şûna Box Relay (vêkolîna wiring diçim nav Relay Box berî şûna), paşê biçe Step 9.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 9. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. Ger wesayîta bi Export Power PEC stendine, pêkanîna "High-Voltage Girtin Service û Power-Up CMK'ê" li ser rûpela 4, paşê jê High-Voltage DC / DC û / an APG Cable High-Voltage ji PEC. Install Caps Interlock eger License de:
    • Ger wesayîta is NOT bi Export Power stendine, biçe Step 11.

[/fusion_content_box][fusion_content_box title=GAV 10. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. Piştî DC / DC û APG kabloyên bilind-voltaja rakirin bi, pull out red Service Switch and connect 19- Connector Way li PEC.
  2. Key li ser:
    • Ger Code Fault 116 / FMI 5 e, hê jî Active, biçe Step 12.
    • Ger Code Fault 116 / FMI 5 çûye, biçe Step 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 11. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. Plug DC / DC û / an kabloyên APG paş nav PEC û çespandin ku Code Fault 116 / FMI 5 e, hê jî Active:
    • Heke hê jî Active, biçe Step 12.
    • Ger Neçalak, li Relays Auxiliary di nava PEC mesh bi. Li şûna PEC. Binêre li Carrier MY09 Power Electric (PEC) Bikini Waxing û Installation, Alternative Carrier Power Electric (PEC) Removal and Installation or 4- Power Battery Electric Carrier (PEC) Bikini Waxing û Installation prosedurên li TRSM2000.
      Jî, inspect the Auxiliary Relay Circuit for loose Interlock Connections causing relay chatter under load see qusûra Code 118 – Fault Auxiliary Voltage High Relay Control Circuit ji bo danasîna circuit).
    • Piştî tamîran bi qediya, biçe Step 14.

[/fusion_content_box][fusion_content_box title=GAV 12. Piştrastkirina berdewamiya circuits bibîne Connector. backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. Girêdana bi navê PEC 19-Way Connector.
  2. Bibire li bibîne 40-Way Connector.
  3. Bipîvin berxwedana li bibîne 40-Way OEM Connector Terminal li pin jêr:
    • Derzî 21 ji bo Pin 31
    • Derzî 22 ji bo Pin 32
    • Derzî 23 ji bo Pin 33
      • Ger ku berxwedana di navbera Pin 21 û pin 31 112-122 Ohms û berxwedana ji pin e 22 ji bo Pin 32, û pin 23 ji bo Pin 33 her 33-37 Ohms in, li şûna bibîne (dîtina Waxing MY09 bibîne û Installation), paşê biçe Step 14.
      • Heke berxwedana e ji range, telafîkirina Harness Vehicle di navbera bibîne û PEC, paşê biçe Step 14.

[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=clean-horizontalcolumns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4ficon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”çep” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”çep” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=small-visibility,medium-visibility,large-visibilityclass=”” id=””][fusion_content_box title=GAV 13. voltaja pîlê Measure.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. ServiceRanger Girêdana bi 9-Way Diagnostic Connector di cab.
  2. ya "Data Monitor" opsyonê hilbijêre.
  3. View Hirç di lîsteyê de battery bilind-voltaja:
    • Pîlê HV Battery J1939 Data HV:
      parametreyê 520250 HV Battery1 Voltage Potential û parametreyê 520323 Pîlê Voltage RB
    • Push li Button Service sor.
    • Eger bi xwendina voltaja li Battery1 Voltage Potential û Battery Voltage RB di nav de ne 10 volts ji hev û din (Pîlê Voltage RB divê dakeve 30 volt dema ku Switch Service sor li dehfdan), li şûna Box Relay. Binêre li Waxing MY09 PEC High-Voltage Relay Box û prosedura Installation li TRSM2000, paşê biçe Step 14.
      Not: "High-Voltage Girtin Service û
      Dîtin High-Voltage Girtin Service û Power-Up Rûtînên divê berî raneke cable bilind-voltaja pêk bê. (Ger sereke
      Relays High-Voltage mesh bi, jê bi hevra bilind-voltaja located in Rear Access Panel berî tamîrên).
    • Eger bi xwendina voltaja li Battery1 Voltage Potential û Battery Voltage RB ne mezintir 10 volts ji hev û din (Pîlê Voltage RB divê dakeve 30 volt dema ku Switch Service sor li dehfdan), li şûna bibîne, paşê biçe Step 14.

[/fusion_content_box][fusion_content_box title=GAV 14. Piştrastkirina repair.backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=noiconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Read More” link_target=”” animation_type=”” animation_direction=”çep” animation_speed=”0.3″ animation_offset=””]

  1. off Key.
  2. , Îlhamek hemû connectors û cable battery neyînî.
  3. Key li ser.
  4. kodên Clear, dîtin Kêmasîyên Neçalak Clear.
  5. Drive wesayîta û hewldana ji bo reset koda.
  6. Check bo codes, dîtin View kêmasîyên Têketina û Neçalak.
    • Ger tu kodên, test complete e.
    • Ger Code sûcê 116 xuya, bibînin error li testkirina, biçe Step 1.
    • Heke koda din ji bilî 116 xuya, dîtin Qusûra Lîsteya Index Code.

[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]