Eaton Fuller Hybrid kļūdas kods 6 – No HCM Operation

Kļūme kodu Eaton Hybrid Drive Systems modeļiem (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P un EH-6E706B-UPG. Hybrid kontroles modulis (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

Defektu kodu 6 – No HCM Operation Detection

Šādi priekšnoteikumi ir jāizpilda, pirms sistēma konstatē kļūmi:

  • HCM aizdedze spriegums ir lielāks nekā 7 volti un mazāk nekā 16 volti.

Nosacījumi, lai iestatītu kļūdas kods Active

Nosacījumi, lai iestatītu Vainas:

  • SVF 12 is set at key on if the HCM detects an internal failure.
  • SVF 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Atkāpšanās Kad kļūdas kods 6 ir noteikts šādi nosacījumi notiek:
• Amber "Pārbaudiet hibrīdas" indikators deg.
• If the fault occurs at power up the vehicle may not crank.

Nosacījumi, lai iestatītu kļūdas kods Neaktīvs

Tikai neaktīvs defekti notīrīti no transmisijas elektronisko vadības vienību (TECU) vai HCM vēsture, izmantojot ServiceRanger. TECU automātiski notīra defekti no vēstures pēc 200 stundas. HCM automātiski notīra defektiem no vēstures kad vainas bijis neaktīvs 200 stundas.

Šo defektu kodu var izraisīt kādu no šiem:

  • SVF 12, 14
    • HCM

Defektu kodu 6 – No HCM Operation Test

jebkurš pārraides daļa Jums ir nepieciešams mums tas ir! Tajā pašā dienā kuģniecības pieejams, vispasaules.

NEED FREE atbalsts kādam no mūsu ekspertiem?

ZVANI TAGAD
EMAIL ASV