Eaton Fuller Code Fault Hybrid 5 Cable Motor Generator AC

Qusûra code for Eaton Hybrid modelên Drive Systems (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P û EH-6E706B-UPG. The Motor/Generator AC Cables are connected from the Motor/Generator to the Inverter. These cables carry up to 500 volts AC 3 qonaxa dema ku wesayîta Di operasyonê de ye.

qusûra Code 5 Wekîlê / Generator AC Cable Motor

  • voltaja Derma Wand dadana mezintir e 7 volt û kêmtir ji 16 volts.
  • FMI 25-27 pêwîst RPM Motor / Generator be mezintir 500 RPM.
  • IMF 28 hewceyê RPM Motor / Generator be kêmtir ji 500 RPM.
  • IMF 29 hewceyê RPM Motor / Generator be kêmtir ji 50 RPM.

Şert û mercên ji bo Set Code Fault Active

Şert û mercên ji bo Set Code Fault:

  • IMF 21: Set dema ku circuit interlock AC vekirî ye.
  • IMF 22, 23, 24 bi set dema niha motor 2-qonaxa zêdetir e 360 Amps ji bo 0.9 MS.
  • IMF 25, 26, 27 bi set dema ku bibîne a wire vekirî single bibîneûdi û niha motor kêmtir e 8 Amps ji bo 200 MS li Leza mezintir an wekhev ji bo 500 RPM û fermana niha ji bibîne mezintir e 20 Amps.
  • IMF 28 Biryar e, dema Motor / Generator niha kêmtir e 8 Amps ji bo 200 MS li speed kêmtir ji 500 RPM û fermana niha mezintir e 20 Amps.
  • IMF 29 di dema destpêkêyên danîn. The bibîne xuyakirin ku Cable AC di navbera motor û bibîne bi şandina derve ve girêdayî ye 20 Amps ji bo 200 MS û bikarbîne Deng.

Dih Dema Code Fault 5 Biryar e ku şert û mercên li jêr pêk:

  • Red "Stop Hybrid" ronîkirin ronahî.
  • Fault di Modula Kontrola Hybrid profîlek (HCM) bîr.
  • Bibîne digire sîstema bilind-voltaja off.
  • HCM berdewam bo kontrolkirina wesayîta hybrid di moda tenê mazotê-.
  • Ger FMI 28, an 29 li hêza xwe amade ye, wesayîta nade meşeke bi.

Şert û mercên ji bo Set Fault Code Neçalak

Tenê kêmasîyên Neçalak dikare ji Unit ji nifşek a Control Electronic kenîştê (TECU) an dîroka HCM bikaranîna ServiceRanger. The TECU automatically kiribin gonehên ji dîroka piştî 200 saetan. The HCM automatically kiribin gonehên ji dîroka piştî code sûcê ku hatiye Neçalak bo been 200 saetan.

Ev koda sûcê dikare ji aliyê yek ji yên jêr ji ber:

  • IMF 21
    • AC Cable Interlock
  • IMF 22, 23, 24
    • bibîne
    • Motor / Generator
    • cable AC
  • IMF 25, 26, 27, 28, 29
    • Motor / Generator
    • Cable AC

qusûra Code 5 – Motor / Generator Test Cable AC

System Component tespît MY08:

High-Voltage AC Harness Connector View

High-Voltage AC Harness Connector View
(Amphenol Connector)

High-Voltage AC Motor/Gen Connector View

High-Voltage AC Motor / Gen Connector View
(Amphenol Connector)

NOT: Bi xweşî hatî ferhenga Refer Eaton Component Hybrid û Connector Location ji bo Locations Connector li Systems MY08

hybrid component connector

System Component tespît MY09:

High-Voltage AC Harness Connector View

High-Voltage AC Harness Connector View
(Amphenol Connector)

High-Voltage AC Motor/Gen Connector View

High-Voltage AC Motor / Gen Connector View
(Amphenol Connector)

NOT: Bi xweşî hatî ferhenga Refer Eaton Component Hybrid û Connector Location ji bo Locations Connector li Systems MY09.

hybrid component connector

Herçiyek beşek ji nifşekî hûn divê em jî heye! heman rojê di shipping License de, cîhanê.

Bi piştgirîya ji ji pisporên?

BANGAWAZÎ NOW
Email Amerîka