[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”35″ margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Eaton Fuller Hybrid Transmission bilanakóða 116 – High Voltage Relays Fault – (MY09 kerfi)
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Kenna kóða fyrir Eaton Hybrid Drive Systems módel (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P og EH-6E706B-UPG. Lestu hér að neðan til að læra hvernig á að prófa, hreinsa og laga bilanakóða villa fyrir Freightliner þína, Mack, Peterbilt, Kenworth, Volvo, International, og þungur-skylda vörubíll og búnaður. Háspennu Liða eru staðsett inni í Power
Electronics Carrier (PEC) í gengi Box eining. There is one Pre-Charge Relay on the positive side, an additional relay on the positive, and on the negative for a total of three relays. Þessar liða eru yfirleitt opnar þegar kerfið er slökkt. Eru liðarnir stjórnað í gegnum Inverter.
villukóðanum 116 – High Voltage Relays kenna uppgötvun
Eftirfarandi forsendur verða að vera uppfyllt áður en kerfið skynjar að kenna:
- Inverter íkveikju spenna er hærri en 7 volt og minna en 16 volt.
Note: Þegar vandræða óvirkur kóða vísa til Vara Diagnostic Mode (PDM)
Skilyrði til Setja bilanakóða Active
- IMF 3 er sett þegar stutt til 12 volt er greind á stjórn hlið af a hár-spenna gengi.
- IMF 4 er sett þegar stutt til jarðar er greind á stjórn hlið af a hár-spenna gengi.
- IMF 5 og FMI 10 eru sett þegar opna hringrás er greind á stjórn hlið af a hár-spenna gengi.
- IMF 7 og FMI 14 eru sett þegar helstu neikvæð gengi er á og Inverter þétti spenna lækkun er minni en 10-volt / 5 sekúndur þegar fyrsta þétti spenna var meiri en 200 volt.
Varaleið Þegar Fault Code 116 er sett eftirfarandi skilyrði eiga sér stað:
- Amber "Athuga Hybrid" ljós lýsir.
- Fault er geymt í Hybrid stjórneinigu (HCM) minni.
- Blendingur kerfi verður ótengdur.
- Transmission defaults start gear to 1st in diesel-only mode.
[/fusion_text][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Skilyrði til Setja bilanakóða óvirkur
Aðeins óvirk galli er hægt að hreinsast úr TECU eða HVS sögu með ServiceRanger. The TECU hreinsar sjálfkrafa galla frá sögunni eftir 200 klukkustundir. The HCM hreinsar sjálfkrafa kenna frá sögunni eftir að bilun hefur verið óvirk 200 klukkustundir.
Þessi galli kóða getur stafað af einhverju af eftirfarandi:
- IMF 3, 4, 5, 7, 10, 14
- Spenna Feedback vír frá DC / DC breytir til HVS
- IMF 4
- Relay Box
- tregðu Switch
- Inverter
- Ökutæki leiðslur milli Inverter og PEC
- Helstu High-Voltage Service Fuse er blásið eða vantar
- DC High-Voltage Cable Interlock
- PEC Red Button Service Switch
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
villukóðanum 116 – High Voltage Relays Fault Test
[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Component Identification:
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14476|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Duetsch 40-vegur pörun tengi view Inverter lág-spenna tengi” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Duetsch-40-way-mating-connector-view.png[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Duetsch 40-vegur pörun tengi view
(Inverter lág-spenna tengi)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_2″ layout=”1_2″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14213|medium” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Mökun tengi view Deutsch 19-vegur ” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Eaton-Fuller-Harness-Connector-View-300×289.jpg[/fusion_imageframe][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
Mating tengi view
(Deutsch 19-vegur tengi)
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_image_id=”” background_color=”#000000″ background_image=”” background_position=”left top” undefined=”” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”20″ margin_bottom=”20″ animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]
ATHUGIÐ: Vísa til Eaton Hybrid Component og tengi Location fyrir Tengja stöðum í MY09 Systems.
[/fusion_text][/fusion_builder_column][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_imageframe image_id=”14672|full” max_width=”” style_type=”” blur=”” stylecolor=”” hover_type=”none” bordersize=”” bordercolor=”” borderradius=”” align=”center” lightbox=”no” gallery_id=”” lightbox_image=”” lightbox_image_id=”” alt=”Inverter til PEC MY09 Systems” link=”” linktarget=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]https://www.globaltransmissionsupply.com/wp-content/uploads/Inverter-to-PEC-MY09.png[/fusion_imageframe][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_modal name=”warnings_cautions” title=”Viðvaranir & varar” size=”large” background=”” border_color=”” show_footer=”yes” class=”” id=””]hætta: Hætta táknar að þú munt vera alvarlega slasaður eða drepinn ef ekki fylgja uppgeíhu málsmeðferð.
Viðvörun: Viðvörun bendir strax hættu, sem gæti leitt til alvarlegrar slysa ef þú fylgir ekki gefið til kynna málsmeðferð.
Varúð: Varúð bendir ökutæki eða eignatjóns gæti komið ef þú fylgir ekki gefið til kynna málsmeðferð.
Note: Ath bendir frekari smáatriði sem mun aðstoða við greiningu eða viðgerð á íhluta / kerfi.
Fylgdu tilgreind málsmeðferð í tilgreindu skyni að koma í veg fyrir slys:
1. Ef hár-spenna keilur eru um ökutækið og læsa er uppsett á PEC, sá eini sem ætti að vera heimilt að hefja ökutæki er sá sem undirritað læsa tag.
2. Áður en vinna á ökutæki eða yfirgefa leigubíl á meðan vélin er í gangi, þú ættir að setja vakt lyftistöng í "N" setja í handbremsu, og loka á hjól.
3. Af öryggisástæðum, alltaf stunda þjónustu bremsum fyrir að velja gír stöðu frá "N."
4. Áður en þú byrjar ökutæki ávallt sitja í bílstjórasætinu, velja "N" á vakt stjórn, og setja handbremsu.
5. Í ökutækjum með ePTO, vélin og / eða
Mótor / Generator getur byrjað á ePTO ham. Aldrei framkvæma allt viðhald eða vinna á bifreið, í þessum ham.
6. 12-Volt Battery jákvæð (+) og neikvæð (-) verður að vera ótengdur á undan hvaða suðu á hvaða Hybrid búin ökutæki.
Varúð: Fylgdu tilgreind málsmeðferð í tilgreindu skyni að koma í veg fyrir búnað bilun eða skemmdir.
Varúð: Sleppir ekki handbremsu eða reyna að velja gír fyrr en loftþrýstingur er á réttum vettvangi.
Varúð: Til að koma í veg fyrir skemmdir á sendingu meðan togað stað á vakt lyftistöng í "N" og lyfta hjólin á jörðu eða aftengja Driveline.
High-Voltage Viðvaranir & varar
- Nota CO2 eða duft slökkvitækja.
- The hár-spenna raflögn er fjallað í appelsínugulum einangrun eða undinn slöngu og merkt með viðvarana á tengin.
- Allir Eaton® Hybrid Diesel / Electric ökutæki verða merkt "Hybrid’ utan á ökutækinu, ásamt vakt miðanum á strik.
- Vísað til OEM fyrir tiltekna staðsetningu undirvagn fest blendingur hluti.
- Ekki skera í appelsínugult hár-spenna snúrur.
- Ekki skera í eða opna PEC.
- Ekki skera í eða opna DC / DC breytir.
- Ekki skera í eða opna Inverter.
A biðminni verður að setja upp og hár-spenna einangrun gúmmí hanska (flokkur 0 með leður hlífar) er þörf áður en vinna á háspennu. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
The gúmmí einangruð hanska sem verður að nota á meðan að vinna á hár-spenna kerfisins er flokkur 0 með leður hlífar. The gúmmí hanska skal prófa fyrir hverja notkun kjölfar gúmmí einangrun hanska próf málsmeðferð sem finnast í "Diagnostic Tools / Service Publications" á bls 6. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
Áður skoðun eða vinna á hvaða hár-spenna snúrur eða íhluti í "High-Voltage Service Lokun og Power-Up" á síðu 4 ætti að fylgja. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
Læsa og Tagout tæki ætti að fjarlægja með tæknimaður sem sett læsa og Tagout tæki á ökutækinu. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
High-spenna gúmmí einangruð hanska (flokkur 0 með leður hlífar) skal nota þegar vinna á einhverju
hár-spenna snúrur. The "High-Voltage Service Lokun og Power-Up Framkvæmd" á bls 4 Fylgja verður áður að fjarlægja allar hár-spenna snúrur. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
High-spenna snúrur og tengi eru appelsínugul og innihalda viðvörun merki á the tengi. High-spenna þættir eru merktir með merkimiða. High-spenna gúmmí einangruð hanska (flokkur 0 með leður hlífar) verður að nota þegar vinna á einhverjum af þessum hlutum. Bilun að fylgja þessum leiðbeiningum getur leitt til alvarlegs líkamstjóns eða dauða.
High-Voltage Service Lokun Verklagsreglur
1. Fylgja "High-Voltage Work Area" aðferð.
2. Finndu rauða PEC Service kveikja á the andlit af the PEC og ýta slökkva.
3. Taktu Þjónusta Switch Cover og setja verkbann sviga (J48506).
4. Festið tag til Læsa Bracket.
5. Tryggja PEC Service rofi getur ekki fært frá burt stöðu.
6. Leyfa kerfinu að setja að lágmarki 5 mínútur til að sinna mikil spenna.
7. Tengjast ServiceRanger og skoða gögn Monitor kennitölu 116 kallast "High-Voltage Rafhlaða Möguleiki". Nota SPN 520323 fyrir J1939 tengsl "rafhlaða spennu RB" (Relay Box).
8. Spennan á að vera 30 volt eða minna. Ef spenna er fyrir ofan 30 volt, virka ekki á ökutækinu og hafðu Eaton® á 1-800-826-HELP (4357).
9. Snúa kveikjulykil burt og halda áfram að gera eða vandræða skref.
Note: Spenna fer niður í núll þegar lykillinn er slökkt.
High-Voltage Service Power-Up Framkvæmd
1. Setja öll hár-spenna tengi í læstum stöðum sínum.
2. Ef þú ert manneskja að vinna á ökutækinu, fjarlægja læsa sviga og merki.
3. Setja læsa sviga yfir Service Switch.
4. Dragðu þjónustu Switch út og láta ökutæki sett fyrir 2 mínútur.
5. Start vehicle when appropriate.[/fusion_modal][fusion_modal name=”component_location” title=”Eaton Hybrid Component og tengi Location ” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][fusion_modal name=”component_location2″ title=”Eaton Hybrid Component og tengi Location MY09 Systems” size=”large” background=”#ffffff” border_color=”” show_footer=”yes” class=”” id=””]

[/fusion_modal][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”SKREF 1.Verify FMIs til staðar.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Endurskoða og fylgja Viðvaranir & varar.
- Sækja Active kóða kenna og FMIs með ServiceRanger með 9-Way greiningartengisins.
- notkun ServiceRanger, Upptaka lestur í "Data Monitor" undir J1939 Gögn HV Rafhlaða: færibreyta 520250 HV Battery1 hugsanlega spennu og breytu 520323 Rafhlaða Spenna RB. Horfa spennu á rafhlöðuspennan RB á takkann á og met spenna skref ef einhver eru til staðar.
- Sem FMIs eru til staðar?
- Ef villukóðanum 116 IMF 3 er skráð, farið í skref 2.
- Ef villukóðanum 116 IMF 4 er skráð, farið í skref 4.
- Ef villukóðanum 116 IMF 5 eða 10 er skráð, farið í skref 6.
- Ef villukóðanum 116 IMF 7 er skráð, farið í skref 13.
[/fusion_content_box][fusion_content_box title=”STEP 2. Staðfestu viðgerð.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt, bíddu 1 mínútu.
- Aftengja 40-Way Inverter Tengi.
- Key á (þetta mun setja bilanakóða 88, ljóst kenna eftir viðgerð).
- Á Vehicle belti, athuga fyrir hvaða spennu á pinna 21, 31, 22, 32, 23 og 33 til jarðar:
- Ef einhver spenna er að finna, fjarlægja 19-Way Connector á PEC og athugið að spenna á Inverter 40-Pin, þá fara í skref 3.
- Ef spenna er enn til staðar, viðgerðir Ökutæki milli Inverter og 40-Pin, þá fara í skref 3.
- Ef spenna er farinn, farið í skref 3
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 3. Staðfestu samfellu í Pec Tengja brautir til jarðar.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- 1. Key burt.
2. Aftengið PEC 19-Way Tengja (rauður Þjónusta Switch ætti enn að vera dreginn út).
3. Mæla viðnám á eftirtöldum 19-Way Tengja skautanna:- Pin 9 að pinna 6 og Pin 9 að pinna 12
- Pin 13 að pinna 6 og Pin 13 að pinna 12
- Pin 17 að pinna 6 og Pin 17 að pinna 12
- Ef opnum hringrás, farið í skref 2.
- Ef einhver viðnám er að finna, skipta um Relay Box, þá fara í skref 14.
[/fusion_content_box][fusion_content_box title=”STEP 4. Staðfestu samfellu í Inverter Tengja brautir.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Aftengið Inverter 40-Way Tengja (19-Þannig Tengi á PEC ætti að vera tengdur með rauðum Service Switch dreginn út).
- Á Vehicle belti, athuga andstöðu við jörðu á pinna 21 til jarðar, Pin 22 til jarðar og Pin 23 til jarðar:
- Ef einhver viðnám frá Inverter Tengi til jarðar er að finna, aftengja PEC 19-Way Connector og langsóttur OEM 40-Way Tengja.
- Ef viðnám er enn að finna með 19-Way aftengd, gera við Vehicle Harness, þá fara í skref 14.
- Ef viðnám er farið með 19-Way aftengd, farið í skref 5.
- Ef mælirinn sýnir OL eða opna hringrás, skipta um Inverter, þá fara í skref 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 5. Staðfestu samfellu í Pec Tengja brautir til jarðar.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Aftengið PEC 19-Way Tengja.
- Á PEC 19-Way Connector, mæla:
- Pin 9, Pin 13 og Pin 17 til jarðar
- Pin 9 að pinna 7, Pin 9 að pinna 10, Pin 9 til PEC Festingar Stud
- Pin 13 að pinna 7, Pin 13 að pinna 14, Pin 13 til PEC Festingar Stud
- Pin 17 að pinna 7, Pin 17 að pinna 14, Pin 17 til PEC Festingar Stud
- Ef einhver viðnám er að finna frá Pec Pins til jarðar, skipta um Relay Box. Sjá MY09 PEC High-Voltage Relay Box tekinn úr og settur málsmeðferð í TRSM2000, þá fara í skref 14.
- Ef mælirinn sýnir OL, endurprófuninni er krafist, farið í skref 4.
[/fusion_content_box][fusion_content_box title=”STEP 6. Staðfestu samfellu PEC Tengja brautir.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Aftengið PEC 19-Way Tengja. (Red Þjónusta Button á PEC skal dreginn út.)(Ekki framkvæma "Hybrid Lokun Framkvæmd" enn.)
- Mál viðnám á PEC Connector:
- Pin 9 að pinna 11
- Pin 13 að pinna 15
- Pin 17 að pinna 19
- Ef mótstöðu frá pinna 9 og Pin 11, og Pin 13 að pinna 15 eru hvor 33-37 ohm og viðnámið frá: Pin 17 að pinna 19 er 112-122 ohm, farið í skref 7.
- Ef einhver viðnám er utan marka, endurstilla tregðu Skipta staðsett inni loftsía opnun eða aftan aðgang Panel af High-spenna öryggi, þá fara í skref 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 7. Hakaðu við hár-spenna snúru interlock á OEM Cable.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Staðfestu að Tregðu Switch er í lagi.
- Mæla viðnám læsingunni Pins á OEM Cable.
hætta: sjá High-Voltage Service Shutdown and Power-Up Procedures. Fylgdu aðferðir til að koma í veg fyrir lost, brenna eða dauða af óviðeigandi meðhöndluð háspennu.- Ef viðnám er 0-0.3 ohm, skipta um Relay Box, þá fara í skref 9.
- Ef viðnám er OL, skipta um High-Voltage DC Cable, þá fara í skref 8.
[/fusion_content_box][fusion_content_box title=”STEP 8. Staðfestu samfellu í Pec Tengja brautir til jarðar.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Mál viðnám á PEC Connector (rauður Service Button Switch er dreginn út):
- Pin 9 að pinna 11
- Pin 17 að pinna 19
- Ef einhver viðnám er OL, skipta um Relay Box (Skoðið raflögn fara í Relay Box áður skipt), þá fara í skref 9.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 9. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Ef ökutæki er búið Export Power PEC, framkvæma "High-Voltage Service Lokun og power-up" á síðu 4, þá fjarlægja hár-spenna DC / DC og / eða APG High-spenna snúru frá PEC. Setja interlock Paprika ef það er laust:
- Ef ökutæki er ekki búin með Export Power, farið í skref 11.
[/fusion_content_box][fusion_content_box title=”STEP 10. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Eftir DC / DC og APG hár-spenna snúrur eru fjarri, pull out red Service Switch and connect 19- Leið Tengi á PEC.
- Key á:
- Ef villukóðanum 116 / FMI 5 er enn virkur, farið í skref 12.
- Ef villukóðanum 116 / FMI 5 er farinn, farið í skref 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”” image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 11. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Stinga DC / DC og / eða APG snúrur aftur í PEC og staðfesta að bilanakóða 116 / FMI 5 er enn virkur:
- Ef enn Active, farið í skref 12.
- Ef óvirkir, The tengd Relays inni PEC eru soðnar. Skipta um PEC. Sjá MY09 Power Electric Carrier (PEC) Flutningur og uppsetning, Alternative Power Electric Carrier (PEC) Removal and Installation or 4- Rafhlaða Power Electric Carrier (PEC) Flutningur og uppsetning verklag TRSM2000.
einnig, inspect the Auxiliary Relay Circuit for loose Interlock Connections causing relay chatter under load see villukóðanum 118 – Tengd High Voltage Relay Control Circuit Fault fyrir lýsingu hringrás). - Eftir viðgerð er lokið, farið í skref 14.
[/fusion_content_box][fusion_content_box title=”STEP 12. Staðfestu samfellu í Inverter Tengja brautir. ” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Tengdu PEC 19-Way Tengja.
- Aftengið Inverter 40-Way Tengja.
- Mál viðnám á Inverter 40-Way OEM Tengi Terminal á eftirfarandi pinna:
- Pin 21 að pinna 31
- Pin 22 að pinna 32
- Pin 23 að pinna 33
- Ef mótstöðu frá pinna 21 og Pin 31 er 112-122 ohm og viðnámið frá: Pin 22 að pinna 32, og Pin 23 að pinna 33 eru hvor 33-37 ohm, skipta um Inverter (sjá MY09 Inverter Flutningur og uppsetning), þá fara í skref 14.
- Ef viðnám er utan sviðs, gera við Vehicle beisla milli Inverter og PEC, þá fara í skref 14.
[/fusion_content_box][/fusion_content_boxes][fusion_content_boxes layout=”clean-horizontal” columns=”2″ title_size=”18px” heading_size=”3″ title_color=”#ffffff” body_color=”#ffffff” backgroundcolor=”#4f4f4f” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” icon_circle=”” icon_circle_radius=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” icon_size=”” icon_hover_type=”” hover_accent_color=”#f41000″ image=”” image_id=”” image_width=”” image_height=”” link_type=”” button_span=”” link_area=”” link_target=”” icon_align=”left” animation_type=”” animation_delay=”” animation_offset=”” animation_direction=”left” animation_speed=”0.3″ margin_top=”” margin_bottom=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””][fusion_content_box title=”STEP 13. Mál rafhlaða spennu.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Tengjast ServiceRanger í 9-Way greiningartengisins í leigubílnum.
- Veldu "Data Monitor" valmöguleikann.
- Skoða eftirfarandi breytur í hár-spenna rafhlöðu listanum:
- HV Battery J1939 Gögn HV Battery:
færibreyta 520250 HV Battery1 Hugsanleg Spenna og Parameter 520323 Rafhlaða Spenna RB - Ýta á rauða Service Button.
- Ef spenna lestur á Battery1 hugsanlega spennu og spennu í rafgeyminum RB eru innan 10 volt hvor öðrum (Rafhlaða Spenna RB ætti að falla að 30 volt þegar rauða Service Rofi var ýtt í), skipta um Relay Box. Sjá MY09 PEC High-Voltage Relay Box tekinn úr og settur málsmeðferð í TRSM2000, þá fara í skref 14.
Note: "High-Voltage Service Lokun og
sjá High-Voltage Service Shutdown and Power-Up Procedures þarf að framkvæma áður en þú fjarlægir hár-spenna snúru. (Ef aðal
High-Voltage Liða eru soðnar, fjarlægja hár-spenna öryggi staðsett í aftan aðgang Panel áður en reynt neina viðgerðir). - Ef spenna lestur á Battery1 hugsanlega spennu og spennu í rafgeyminum RB eru meiri en 10 volt hvor öðrum (Rafhlaða Spenna RB ætti að falla að 30 volt þegar rauða Service Rofi var ýtt í), skipta um Inverter, þá fara í skref 14.
- HV Battery J1939 Gögn HV Battery:
[/fusion_content_box][fusion_content_box title=”STEP 14. Staðfestu viðgerð.” backgroundcolor=”” icon=”” iconflip=”” iconrotate=”” iconspin=”no” iconcolor=”” circlecolor=”” circlebordersize=”” circlebordercolor=”” outercirclebordersize=”” outercirclebordercolor=”” image=”” image_id=”” image_width=”” image_height=”” link=”” linktext=”Lestu meira” link_target=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]
- Key burt.
- Endurtengja alla tengi og neikvæð rafhlaða snúru.
- Key á.
- Hreinsa númer, sjá Hreinsa Óvirk Gallar.
- Aka ökutækinu og reyna að endurstilla kóða.
- Athugaðu að númerum, sjá Skoða virkar og óvirkar Gallar.
- Ef engin númerum, prófun er lokið.
- Ef bilun Code 116 birtist, finna villu í prófun, farið í skref 1.
- Ef kóða annar en 116 birtist, sjá Kenna Code Index Listi.
[/fusion_content_box][/fusion_content_boxes][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container][fusion_global id=”13788″]