Eaton Fuller Cód Locht Hibrid 6 – No HCM Operation

Locht cód le haghaidh Eaton Hibrid samhlacha Córais Drive (MY08) EH-8E306A-U, EH-8E306A-UPG, EH-8E306A-UP, EH-8E306A-CD, EH-8E306A-T, EH-6E606B-CD, (MY09) EH-8E406A-U / P, EH-8E406A-UP, EH-8E406A-UPG, EH-8E406A-CD, EH-8E406A-CDG, EH-8E406A-CDR, EH-8E406A-T, EH-6E706B-CD, EH-6E706B-P agus EH-6E706B-UPG. An Modúl Rialaithe Hybrid (HCM) is mounted to the transmission and it contains all of the software to control both the hybrid power electronics as well as the transmission operation.

locht Cód 6 – No HCM Operation Detection

Ní mór na réamhchoinníollacha seo a leanas a chomhlíonadh sula bhraitheann ar an gcóras an locht:

  • Is é voltas adhainte HCM níos mó ná 7 volta agus níos lú ná 16 volta.

Coinníollacha a Socraigh Locht Cód Gníomhach

Coinníollacha a Socraigh Locht:

  • CAI 12 is set at key on if the HCM detects an internal failure.
  • CAI 14 is set when HCM can not complete writing to the Electrically Erasable Programmable Read-Only Memory (EEPROM) during shut down.

Fallback Nuair Locht Cód 6 is set the following conditions occur:
• Amber "Seiceáil Hibrid" illuminates solas.
• If the fault occurs at power up the vehicle may not crank.

Coinníollacha a Socraigh Locht Cód Neamhghníomhach

Ní féidir ach lochtanna neamhghníomhacha a ghlanadh as an tAonad um Rialú Leictreonach Tarchurtha (TECU) nó HCM Stair ag baint úsáide as ServiceRanger. An TECU nglanann go huathoibríoch ar an lochtanna ó stair i ndiaidh 200 uaireanta. An HCM nglanann go huathoibríoch ar an lochtanna ó stair tar éis an locht a bheith Neamhghníomhach le 200 uaireanta.

Is féidir é seo cód locht a ba chúis leis aon cheann díobh seo a leanas:

  • CAI 12, 14
    • HCM

locht Cód 6 – No HCM Operation Test

aon cuid tarchurtha ní mór duit ní mór dúinn é! loingseoireachta lá céanna ar fáil, ar fud an domhain.

MÓR TACAÍOCHT SAOR IN AISCE ÓN ÁR SHAINEOLAITHE AMHÁIN DE?

CALL ANOIS
EMAIL US